BEMO Fire Tested Liner Deck System

Verified by manufacturer 2 days ago

Maximum: 0.18 W/m²·K

BEMO Project Engineering UK Ltd Variant:
Product certifications:
  • Warringtonfire

    Warringtonfire

    Certificate type

BEMO aluminium halter on a liner deck Broof(t4).

Jump to:
+44 (0)1773 853694 Website

Application

Suitable for roofs 1.5–70° pitch.

Description

BEMO standing seam aluminium panel on various height aluminium halters; 5 mm thick thermal-break pads fixed to various height top-hat sections, through the vapour control layer to liner deck.

Features and benefits:

  • Non-penetrative.
  • Broof(t4) classification; which can include any insulation thickness between the minimum and maximum variants.
  • For roofs 1.5–70° pitch.
  • Halter height and top-hat height determined by thermal calculation – please contact BEMO technical for specific U-value requirements.

General information

Color

Grey

White

Other

Finish

Mill

Embossed

Material

Aluminium

Steel

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems

Classification data

System performance

Broof(t4) classification.

Liner sheets

-

Material

TP 32-200-1000 TS liner deck, 0.7 mm, BWLE, steel.

Primary fasteners

-

Manufacturer guidance

Refer to BEMO calculations for fixing type and frequency and insert requirements.

End and side laps

Stitched.

Guidance for specification option:

  • Side laps of sheets to be stitched together with rivets.
  • Side laps must be stitched as each adjacent sheet is laid.
  • Minimum 65 mm to coincide with purlin / support position. Subject to project engineering requirements.

Air and vapour control layer

-

Material

BEMO Foil-Plus.

Guidance for specification option:

Lay as work proceeds ensuring continuity with reflective side facing the interior of the building. Vertical and horizontal overlaps should be a minimum of 150 mm.

Sealing

BEMO Foil-Plus tape.

Thermal insulation

Superglass Cladding Mat 35 – two layers, 200 mm thick compressed to 380 mm.

External sheets

-

Material

Aluminium profiled sheets, N65/370, 0.9 mm, natural stucco embossed mill finish.
Aluminium profiled sheets, N65/400, 0.9 mm, natural stucco embossed mill finish.

Primary fasteners

-

Manufacturer guidance

Please refer to BEMO Technical for project specific fixed point calculations.

Secondary fixings

-

Manufacturer guidance

Closure of roll formed profile by means of mechanical seaming around the head of supporting halters.

System accessories

-

Manufacturer guidance

As per project requirements.

Thermal break

Thermal barrier pads (402-CB12) 5 mm thick.

Verge detail

Extruded aluminium alloy (EN AW 6063 T6) verge channel.
Extruded aluminium alloy (EN AW 6063 T6) gable hooks.
Fabricated aluminium alloy (EN AW 1050A) tolerance flashing.

Manufacturer guidance

Verge components.

Ridge detail

Extruded aluminium alloy (EN AW 6063 T6) zed spacer.
Fabricated aluminium alloy ridge filler plates.
Profiled ridge filler blocks (LDPE) to suit.

Manufacturer guidance

Ridge components.

Eaves detail

Profiled eaves filler blocks (LDPE) to suit.
Self-adhesive (PUR Flexible Foam) eaves tape.
Extruded aluminium alloy (EN AW 6063 T6) drip angle.

Manufacturer guidance

Eaves components.

Halters

Extruded aluminium alloy halters - 100 mm.
Extruded aluminium alloy halters - 120 mm.
Extruded aluminium alloy halters - 140 mm.
Extruded aluminium alloy halters - 160 mm.
Extruded aluminium alloy halters - 180 mm.
Extruded aluminium alloy halters - 200 mm.
Extruded aluminium alloy halters - 220 mm.

Manufacturer guidance

  • Varying heights available, consult manufacturer and insert requirements.
  • Please refer to BEMO Technical for project specific u-value calculations.

Top hats

Fabricated galvanized structural steel (S280GD minimum) top hats - bespoke heights.

Manufacturer guidance

  • Varying heights available, consult manufacturer and insert requirements.
  • Please refer to BEMO Technical for project specific u-value calculations.

Sustainability data

Material

Aluminium
Steel

Product certifications

Warringtonfire

Warringtonfire

Broof(T4)

Literature

BEMO Fire Tested Liner Deck System

BEMO Fire Tested Liner Deck System

Case studies

Manchester Airport Terminal 2, England

Manchester Airport Terminal 2, England

Moto Services, Rugby

Moto Services, Rugby

Similar products from BEMO Project Engineering UK Ltd

BEMO Combi-Bar Liner Deck System

BEMO Combi-Bar Liner Deck System

BEMO Combi-Bar Structural Deck System

BEMO Combi-Bar Structural Deck System

BEMO GFK Liner Deck System

BEMO GFK Liner Deck System

BEMO GFK Structural Deck System

BEMO GFK Structural Deck System