BauderSOLAR G LIGHT integrated solar PV mounting system for Biodiverse Green Roof (flat roof only).

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for biodiverse green roof (flat roofs only).

Description

BauderSOLAR G LIGHT integrated solar PV mounting system for Biodiverse Green Roof, for flat roofs only. An integrated mounting solution for photovoltaic renewable energy within a green roof, where the substrate and vegetation provide the ballasted installation mechanism, which removes the need for penetrating the waterproofing to secure the mounting units to the roof.


A key element of the BauderSOLAR G LIGHT system is that the front edge of the PV panel is set at around 300 mm above the level of the substrate, which allows liberal growing space for the biodiverse vegetation without blocking light to the polycrystalline solar cells that would otherwise reduce the efficiency of the panels. This height setting also enables light and moisture to reach beneath the panel to support the plants below.


Features and benefits:

  • Allows entire roof to qualify as a biodiverse green roof.
  • No roof penetrations for the panels as the green roof substrate acts as ballast.
  • Front edge of the panel is set at around 300 mm above the substrate.
  • Green roof can reduce the temperature of the PV panel.
  • System can be retrofitted on many roofs.
  • Installation possible on level decks.
  • Shaded and sheltered areas attract a broad range of beneficial wildlife.
  • Waterproofing guarantee remains uncompromised.
  • Raised modules allow light and moisture to access vegetation.
  • The green roof has a cooling effect on the roof, which can increase panel output by up to 5%.
  • Allows for energy generation in areas where it was not previously possible.

General information

Length

Bespoke

Width

Bespoke

Uniclass

Ss_45_40_47_09 Brown roof systemsPrimary

CAWS

Q37/130 Extensive green roof

Specification data - Brown roof systems

Protection

-

Protection layer

BauderGREEN FSM 600 protection mat.

Guidance for specification option:

Heavy duty protection layer made from polyester and polypropylene fibres. Laid on the completed waterproofing to protect the completed waterproofing from damage (not required for inverted roofs). Normally installed under the entire green roof area but kept clear of all outlets and drainage trims. FSM mats should be lapped by 150 mm at all joints. Loose laid. Laps to be sealed by lightly heating overlap area with a propane gas torch/ hot air welding gun to melt the polypropylene fibres and then press seal the two fleece sheets together.

Sufficient protection fleece must be allowed for so that it may be installed to all abutment upstands and edge details, in accordance with the Bauder instructions. Extend to full height of the upstand and secure in place by using a lead or fabricated metal counter-flashing.

Should be trimmed well back from ALL outlets.

Openings in landscape restraint kerbs (where present – roof slopes above 5º), the protection layer should be cut away from the openings/ gaps to avoid impeding drainage.

  • Width: 2 m.
  • Length: 30 m.
  • Thickness: 4 mm.
  • Coverage: 60 m².
  • Weight (saturated): 3.6 kg/m².
  • Material: Polyester and polypropylene fibre mix.

BauderGREEN SV 600 protection and moisture mat.

Guidance for specification option:

Lightweight protection layer made from recycled man-made fibres. Laid on the completed waterproofing to protect the completed waterproofing from damage (not required for inverted roofs).

Normally installed under the entire green roof area but kept clear of all outlets and drainage trims.

Eco-mat should be lapped by 150 mm at all joints. Loose laid.

Sufficient protection fleece must be allowed for so that it may be installed to all abutment upstands and edge details, in accordance with the Bauder instructions. Extend to full height of the upstand and secure in place by using a lead or fabricated metal counter-flashing.

Should be trimmed well back from ALL outlets.

Openings in landscape restraint kerbs (where present – roof slopes above 5º), the protection layer should be cut away from the openings/ gaps to avoid impeding drainage.

  • Width: 2 m.
  • Length: 30 m.
  • Thickness: 6 mm.
  • Coverage: 60 m².
  • Weight (saturated): 3.8 kg/m².
  • Material: 100% Recycled man-made fibre mix.

BauderGREEN GGM 6 rubber protection mat.

Guidance for specification option:

Bauder's Heaviest duty protection layer made from recycled shredded tyres. Laid on the completed waterproofing to protect the completed waterproofing from damage (not required for inverted roofs, not for use with PVC waterproof membranes/ Bauder Single Ply Thermofol PVC Roof system).

Normally installed under the entire green roof area but kept clear of all outlets and drainage trims.

Normally installed to provide access over waterproofing in heavily trafficked areas

Pro-mat should be lapped by 150 mm at all joints. Loose laid. Where landscaping installation is not imminent, loose laps should be taped with gaffer tape to eliminate the trip hazard.

Sufficient protection fleece must be allowed for so that it may be installed to all abutment upstands and edge details, in accordance with the Bauder instructions. Extend to full height of the upstand and secure in place by using a lead or fabricated metal counter-flashing.

Should be trimmed well back from ALL outlets.

Openings in landscape restraint kerbs (where present – roof slopes above 5º), the protection layer should be cut away from the openings/ gaps to avoid impeding drainage.

  • Width: 1.25 m.
  • Length: 10 m.
  • Thickness: 6 mm.
  • Coverage: 12.5 m².
  • Weight (saturated/ dry): 4.3 kg/m².
  • Material: 100% recycled shredded rubber.

Moisture control

-

Drainage layer

BauderSOLAR G LIGHT BioSolar photovoltaic mounting system.

Guidance for specification option:

PE-HD integrated solar PV mounting system specifically for Bauder biodiverse or extensive greenroofs. Used on roofs 0–5° finished falls. Loose laid (open cups up) on to the Protection Layer (or WFRL on inverted roofs) over completed waterproofing.

BauderSOLAR G LIGHT should be used in conjunction with BauderGREEN Flora 3 Seed Mix, BioSOLAR and shade tolerant mix which contains both drought and shade tolerant herb and wildflower species and is suitable for roofs with a fall of up to 5°. BauderSOLAR Anchor boards (2 x 1 m) must be ballasted using Bauder substrate growing medium, applied above the filter fleece and then built up to a minimum depth of circa 100 mm. Allowance should be made for any settlement that may occur. Please see the project specific BauderSOLAR G LIGHT technical report for further information and required substrate depth.

Weight: 156 kg/m². (Includes weight of solar module and saturated Bauder Biodiverse green roof based on substrate depth 130 mm).

PV module specification – refer to NBS Engineering services Section V14, clauses 310 and 315 and the corresponding BauderSOLAR G LIGHT technical report for further information on scheme design or BauderSOLAR G LIGHT installation guidelines for further information on installation method. BauderSOLAR G LIGHT is designed to be installed by a Bauder approved and trained contractor only. The number of mounts and fixings required will vary from project to project. Please contact manufacturer for a project specific technical report for further information. Windload and snowload calculations will also be provided on a project specific basis and will determine ballast requirements and substrate depths.

BauderGREEN DSE 40 drainage board.

Guidance for specification option:

PE-HD water storage and multi-directional drainage layer. Used on roofs 0–5° finished falls. Loose laid (open profile cup up) on to the Protection Layer (or WFRL on inverted roofs) over completed waterproofing to provide continuous drainage within hard and soft landscaping. It is primarily used where the load is moderate to high, such as extensive and intensive green roofs. Its compressive strength makes it suitable beneath paving laid on sand/ cement or gravel bedding or within planter beds.

Boards are to be butted up against the BauderSOLAR G LIGHT. BauderGREEN DSE 40 to DSE 40 boards are to be interlocked by a minimum of one profile cup and all board joints staggered. The ‘X’ stamped impression on the highpoint of the cup moulding indicates where boards overlap. Cut to fit closely around penetrations and outlets.

  • Size: 1.04 x 2.03 m (2.1 m²).
  • Nominal thickness: 2 mm
  • Depth: 40 mm.
  • Coverage: 2 m² (approximately).
  • Water storage: 13.5 L.
  • Filling capacity: 21 L.
  • Compressive strength: 80 kN/m² empty/ >1000 kN/m² filled.
  • Weight (saturated): 15.3 kg/m².
  • Material: 100% recycled high-density polyethylene.

The drainage/ water storage board also provides a suitable base surface for building concrete or brick kerbs/ walls. The specified infill haunching should be installed over the board to the required depth of cover, poured directly into the profile cup of the board. These should be constructed to provide an adequate support for the raised masonry planters.

BauderGREEN WSP 75 / 50 reservoir board.

Filter membrane

BauderGREEN FV 125 filter fleece.

Guidance for specification option:

Fine mesh PP geotextile used in conjunction with Bauder substrates. BauderGREEN FV 125 filter fleece is designed to separate and contain Bauder substrates from the drainage element of the green roof system (for slopes 0–5°). It prevents fine material from being washed out of the substrate layer. For use in DSE40 areas only.

Loose laid over the drainage layer. The fleece should be taken up the sides of the substrate between the substrate and drainage trim or pebble margin. Fleece joints should be overlapped 150 mm. Fleece should not be taken over the top of drainage outlets.

Upstands (soft landscaping): Extend up, between vegetation barrier and growing medium and trim flush with finished surface level.

Upstands (Hard landscaping): Extend to top of perimeter abutments and trim flush just below finished surface level.

  • Weight (saturated): 0.125 kg/m².
  • Pore size: 0.13 mm.
  • Thickness: 1 mm.
  • Roll size: 1 x 100 m/ 2 x 100 m.
  • Coverage: 100 m²/ 200 m².
  • Water storage: None.
  • Material: Polypropylene fleece.

Substrate

BauderGREEN SUB-BM UK biodiverse substrate.

Guidance for specification option:

Recycled crushed brick, expanded clay, shale, composted pine bark. Depth for BauderSOLAR G LIGHT areas is dependent on the ballasting requirements following windload calculation. Depth to DSE 40 areas, minimum 100 mm.

Lightweight, free draining substrates designed as a growing medium for a range of different plant species. This FLL/ GRO compliant substrate provides a free draining, growing medium for biodiverse green roof systems. Additionally, it provides aeration qualities with some inherent water retention.

  • Material: Recycled crushed brick, expanded clay, shale, composted pine bark.
  • Maximum Weight (saturated): ≤1200 kg/m³.
  • Typical supply weight: c. 950 kg/m³.
  • Water storage (by volume): 35%.
  • pH value: 6–8.5.
  • Bulk bag size: 1.25 m³.
  • Small bag size: 25 L.

Applied directly into the profile cups of the Bauder SOLAR Anchor Boards.

Installed above the BauderGREEN FV 125 filter fleece in Bauder DSE40 Drainage and Protection Layer areas.

Substrates are raked out to give an even coverage of the required depth after settlement.

Handle in the driest condition possible. Do not handle or install when wet or frozen.

Start by applying two equal layers, building up to the required maximum depth.

Gently firm each layer before spreading the next. Allowance should be made for any settlement that may occur. It is recommended that ‘measuring stick’ markers of the required depth be used around the roof area to ensure that a minimum acceptable thickness of growing medium is achieved.

Depending on size and access of the project the ‘substrate’ can be supplied by various methods i.e. tipper, Big bags, or sacks. Prior to costing this element of the installation, the ‘Bauder Approved Contractor’ must contact Bauder Ltd so that they may advise on the best solution on any specific contract.

Important note regarding alternative substrates:

Alternative substrates are not recommended for Bauder supplied planting.

Vegetation barrier

Not required.

20/ 40 mm round river washed pebbles.

Guidance for specification option:

Recommended, supplied by others.


A vegetation barrier must be provided to all perimeters, abutments penetrations including protrusions i.e. man-safe posts etc. Recommend 20/ 40 mm rounded river washed pebbles.

Stones/ aggregates with sharp edges must not be used i.e. flint.

In accordance with current GRO guidelines, the specified barrier widths are as follows:

  • Minimum 300 mm but increasing to 500 mm at vertical walls with opening windows or doors or to abutments with opening rooflights.
  • Every 40 m, there is a 30 mm high barrier constructed of non-flammable materials or a one metre wide strip of solid paving, gravel or pebbles.
  • At all open drainage perimeters, drainage trim must be used to contain the vegetation barrier.
  • Vegetation barrier removal or reduction of the recommended width: Pebble vegetation barriers function as a fire break between potentially flammable dry vegetation and abutting construction materials that are also potentially flammable, to prevent fire spreading. These can be seen as an aesthetic issue for smaller green/ blue roof areas and for this reason some clients/ designers choose to reduce this width or otherwise remove the barrier altogether.

The current barrier guidelines are set by the GRO codes of practice that Bauder follows and promotes. These are guidelines and not currently a legal requirement under British Standards or Building Regulations. However, not following these guidelines may affect an insurance claim in the unlikely event of a fire. Consequently, Bauder Ltd cannot accept liability for issues arising from non-compliance with the current GRO guidelines.

Manufacturer guidance

DO NOT INSTALL into the BauderSOLAR G Light Board.

Waterproofing

Bauder Total Green Roof System Roof Covering System.

Bauderflex Green Roof System.

Bauder Single Ply Thermofol PVC Roof system.

Bauder Single Ply Thermoplan T Flexible Polyolefin Roof system.

Bauder LiquiTEC Cold Liquid Applied Roof System.

Show more

Manufacturer guidance

To be fully specified separately.

Vegetation

BauderGREEN Flora 3 Seed Mix BioSOLAR and shade tolerant mix.

Guidance for specification option:

A broad mix of low growing and some shade tolerant species ideal, for most roof environments. It is also the mix Bauder recommend for BauderSOLAR G LIGHT installations.

  • No of Species: 49.
  • Wildflowers: 31 (65%).
  • Annuals: 8 (20%).
  • Sedge & Grasses: 8 (15%).
  • Sedum: 2.
  • Coverage: 100 g/m² of mix (mix includes a blend of selected seeds, bulking aggregate, seed adhesive, organic nutrients and beneficial Mycorrhizal fungi.
  • Packaging: 2 kg bag (20 m² coverage), 5 kg bag (50 m² coverage), 20 kg bag (200 m² coverage).
  • RHS Perfect for pollinators: 35 plant species.
  • Laval Food: 12 plant species.

NOTE:

All seed mixes are subject to seasonal seed availability.

Installation details:

The Bauder Flora Seed Mixes are specifically designed for sowing at roof level, they contain tackifier and fertilizer with the seed to ensure the seed is stuck to the substrate and not blown or washed off the roof, this ensures the highest germination rates.

The ideal time for seeding is in the spring and autumn. Please note that increased post installation aftercare will be required for installations that take place during the summer and winter months. Please note that the best time to plant seeds is springtime (late March-April.) or early autumn (Sept/ Oct).

Avoid sowing in strong winds. The substrate is to be watered immediately prior to application of the seed mix. Sow approximately 50% of the mix longitudinally down the roof, and then over-sow at 90° with the remainder of the mix. DO NOT RAKE THE SEED MIX INTO THE SUBSTRATE SURFACE.

The seed mix needs light to germinate.

Establishment Watering Requirements:

The substrate will have been watered prior to application of the seed mix. Please note that the seed mix should only then be lightly watered in during the summer or where activation of the adhesive element is required in exposed locations. Please avoid over-watering to prevent seed washout. Once the seeds have germinated, it is essential that the growing medium is kept moist for a further 10 week period until planting is established. It is the responsibility of the roofing contractor to liaise with the main contractor/ building owner to provide water and ensure that the necessary watering programme (as indicated above) is instigated following installation.

An adequate mains water supply of sufficient pressure must be available and operational prior to the plants being delivered and installed. Initial watering must be by surface mounted sprinklers. Refer to the Bauder Watering Guide document for further information on watering. Bauder Ltd accepts no responsibility whatsoever for the condition of installed planting that is not properly watered or irrigated following landscaping works.

BauderGREEN SB Sedum Blanket System & BauderGREEN Flora 3 Seed Mix, BioSOLAR and shade tolerant mix combination.

Guidance for specification option:

BauderGREEN SB Substrate Sedum Blanket System is a mature vegetation blanket, sown with a broad variety of Sedum. It is intended for application directly over levelled Bauder FLL compliant, BauderGREEN SUB-EM UK Extensive Substrate (see Product Data Sheet) as the underlying growing medium. The product is designed to enable rapid rooting to the substrate to speed up establishment times.

The SB Substrate Sedum Blanket is grown in the UK. Typically, it is not supplied until it is at least one year old, this ensures the root structure has developed, enabling it to cope with harvesting, transportation and relaying which can stress young sedum plants. The vegetation within this product is a broad mix of hardy sedum species.

  • Maximum Saturate Weight: ≤24kg/m².
  • Thickness: 30–40 mm.
  • Typical Supply Size: 1 x 2.4 m.
  • Long Roll Sizes (for use with crane attachment): 1 x 5–10 m.
  • pH Value: 6.5–7.
  • Sedum Species: circa 14–17 (The species mix is adjusted from time to time, contact Bauder Technical for further information).

Lay immediately on delivery.

Growing medium condition: Immediately prior to planting, the whole system should be thoroughly watered to ensure that the water storage/ drainage board is filled and the substrate growing medium saturated.

Blankets should be laid diagonally or perpendicular to the slope of the roof. Stagger joints, butt together or slightly overlap to prevent gaps. Blankets are not to be stretched. Thoroughly water using surface sprinklers immediately after installation and substrate dressing, ensuring that the blankets and substrate are fully saturated before moving on to the next area.

BauderGREEN SB Substrate Sedum Blanket System should only be layed by skilled operatives. Care should be taken not to traffic the sedum during or after installation. See Bauder’s Green Roof Installation Guide for full details.

Establishment Watering Requirements:

BauderGREEN SB Substrate Sedum Blanket System requires surface watering for the first 4 weeks following installation (to ensure the substrate remains moist). It is the responsibility of the roofing contractor to liaise with the main contractor/ building owner to provide water and ensure that the planted and fertilized growing medium is thoroughly irrigated immediately after installation.

An adequate mains water supply, of sufficient pressure, must be available and operational prior to the plants being delivered and installed. Initial watering must be by surface mounted sprinklers. See the Bauder Watering Guide document for detailed information on watering requirements. Bauder Ltd accepts no responsibility whatsoever for the condition of installed planting that is not properly watered or irrigated following landscaping works.

BauderGREEN Flora 3 Seed Mix, BioSOLAR and shade tolerant mix to areas underneath the PV panels, please follow guidance notes for Bauder Flora 3 Seed Mix.

Note:

Other vegetation options are not advisable directly under or around the BauderSOLAR G LIGHT system.

Fertilizer

BauderGREEN DU UK organic slow release fertiliser.

Guidance for specification option:

Bauder Sedum Blankets are grown in a shallow growing medium which contains very little nutrient, so the annual application of fertilizer is crucial to ensure that the plants remain healthy. Fertilizer should ideally be applied during March/ April, as it helps the plants to prepare for extreme weather conditions and flowering whilst also allowing the different species to gain sufficient nutrients without competing against each other.

Organic fertilizer can be obtained direct from Bauder in 25 kg bags, which is sufficient for an area of 312.5 m² when applied at the recommended rate of 80 g/m². Areas of up to 30 m² may be applied using either a handheld spreader or strewn by hand from a bucket. Larger roofs should always be done using a trolley applicator, which can be purchased direct from Bauder. Always apply the fertilizer at the given rate written on the bag.

It is recommended that the fertilizer is lightly ‘watered in’ immediately after application, to avoid “burning” of the foliage, which may occur if fertilizer pellets settle on the leaves. Dung-based organic fertilizers should be avoided.

Bauder Maintenance services:

BauderSOLAR G LIGHT system has relatively low maintenance requirements, however they are extremely important to the condition and performance of the system.

Example maintenance requirements below:

  • Bauder extensive substrate has not eroded and correct depth of ballast is in place.
  • All visible fixings are secure and there has been no movement of mounts/modules.
  • No vegetation is growing around/ through mount fixings.

Removing unwanted leaf litter that has fallen onto the roof surface.

  • Any vegetation which has encroached into drainage outlets, Inspection chambers, walkways and the vegetation barriers (pebbles) should be removed.
  • Remove any weed growth that will exceed 30 mm in height, is invasive or undesirable (if necessary, this can be sprayed with a Glyphosate based herbicide). Any vegetation that shades the modules, however thin will have an impact on PV output and must be cropped.
  • Damage to the landscaping should be reported to the building owner.

Manufacturer guidance

For BauderGREEN SB Substrate Sedum Blanket Areas only.

Maximum Slope

5°.

Accessories

BauderGREEN AL 150 edge trim.

BauderGREEN KS ALU 250 inspection chamber.

Guidance for specification option:

The BauderGREEN KS ALU 250 inspection chamber is fabricated from a perforated aluminium sheet with an opening/ lockable lid and is used for intensive and extensive soft landscaping, as well as ballasted inverted roofs. Install centrally over rainwater outlets. A simple on-site modification allows the unit to be used over outlets that are located close to wall or kerb abutments.

The Inspection Chamber is suitable for landscaping depths of less than 100 mm. Where landscaping is deeper than 100 mm, the 50 mm or 100 mm height adaptors can be added as necessary to achieve the required height to be level with or slightly proud of the surrounding landscaping.

Surround: Using 20/ 40 mm grade washed pebbles; the inspection chamber must be surrounded by a 500 mm vegetation barrier to prevent unwanted growth obstructing the drainage system.


BauderGREEN KS ALU 250 inspection chamber:

  • Material: 1.5 mm aluminium (2 mm lid).
  • Length: 250 mm (chamber only).
  • Width: 250 mm (chamber only).
  • Height: 100 mm.
  • Weight: 950 g.
  • Colour: Silver grey (RAL 9006).

BauderGREEN KS AE 50 chamber height adaptor.

Guidance for specification option:

  • Material: 1.5 mm aluminium.
  • Length: 250 mm.
  • Width: 250 mm.
  • Height: 50 mm.
  • Weight: 250 g.
  • Colour: Silver grey (RAL 9006).

BauderGREEN KS AE 100 chamber height adaptor.

Guidance for specification option:

  • Material: 1.5 mm aluminium.
  • Length: 250 mm.
  • Width: 250 mm.
  • Height: 100 mm.
  • Weight: 450 g.
  • Colour: Silver grey (RAL 9006).

Jute Anti-Erosion Net (supplied by others).

Guidance for specification option:

Bio-degradable jute netting supplied by others. Installed over plug planted/ seeded growing medium to prevent wind erosion until planting established.

Where the exposure of the roof is such that there is a risk of the substrate being subject to wind erosion, provision must be made to install biodegradable (Jute) erosion net (supplied by others) over the installed substrate, to prevent erosion until the plants are established. The net should be secured using bio-degradable pegs.

Show more

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Green Roof Systems - Bauder Brochure

Green Roof Systems - Bauder Brochure

Green Roof Design Considerations - Bauder

Green Roof Design Considerations - Bauder

BauderSOLAR G LIGHT Biosolar Mounting System - Technical Data Sheet

BauderSOLAR G LIGHT Biosolar Mounting System - Technical Data Sheet

Solar PV Systems - Bauder brochure

Solar PV Systems - Bauder brochure