Verified by manufacturer 6 months ago
BBA Agrément Certificate
Certificate type
EPD
Certificate type
CCPI System
Certificate type
Loose ballasted, inverted roof, single ply membrane waterproofing system suitable for new build, refurbishment and extensive green roof applications and used primarily on concrete decks.
Single ply Thermoplan T flexible polyolefin (FPO) inverted single-ply waterproofing roof system, loose laid and ballasted. Bauder Single Ply Thermoplan T Flexible Polyolefin Inverted Roof system is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios. Can also be used for extensive green roof situations.
Characteristics of the system
Verified properties
Finish | Smooth |
Material | Flexible polyolefin (FPO) |
Shape | Square Rectangle |
Height | 2 mm 3.5 mm Guidance for specification option: Total thickness for BauderTHERMOPLAN T 15 V fleece-backed reinforced FPO membrane. 3.5 mm with 2mm fleece 1.5 mm Manufacturer guidanceBauderTHERMOPLAN membrane comes in 3 unfleecebacked thicknesses and 1 fleecebacked option. |
Warranty description | Manufacturer guidanceGuarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer. For full details and further information regarding guarantees and alternative systems please contact your local Bauder Representative or technical@bauder.co.uk. |
Uniclass | |
CAWS | J42/120 Inverted roof covering |
Product range |
Preparation | |
Horizontal work | Manufacturer guidanceContact Bauder to confirm substrate suitability if required. |
Skirtings and vertical work | As 'Horizontal work'. |
Separating layer | Not required.Guidance for specification option: For Thermoplan T 15 V. Not for use with KSD FBS AVCL. BauderSYN GV 120 glass fleece protection layer.Guidance for specification option: Lightweight glass isolation fleece, loose-laid to provide isolation in-between BauderPIR FA G16 Tapered Insulation and Thermoplan T (unbacked – PVC membrane).
|
Waterproof covering | |
Type | BauderTHERMOPLAN T 15 V.Guidance for specification option: BauderTHERMOPLAN T 15 V Fleece-Backed Membrane is a polyester reinforced flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. A polyester fleece is laminated to the underside of the membrane in factory conditions. This combination gives high tensile strength, good thermal stability and flexibility.
BauderTHERMOPLAN T 12, T 15, T 20 Membrane.Guidance for specification option: BauderTHERMOPLAN T 12, T 15, T 20 is a 1.2 mm, 1.5 mm, and 2 mm gauge polyester-reinforced, flexible polyolefin membrane (FPO): an alloy of thermoplastic and rubber. This combination gives high tensile strength, good thermal stability and flexibility.
|
Insulation | |
Type | Bauder JFRI PREMIUM+ Inverted Insulation.Guidance for specification option: Insert required thickness, 85–240 mm in 5 mm increments. Designed specifically for inverted roof applications.
Consult manufacturer's literature for further details. Bauder JFRI PREMIUM (300) Inverted Insulation.Guidance for specification option: Insert required thickness, 90–240 mm in 5 mm increments. Designed specifically for inverted roof applications.
Consult manufacturer's literature for further details. Bauder XPS (300) Inverted Flatboard.Guidance for specification option: A range of flat high-performance, rigid extruded polystyrene insulation boards.
Bauder XPS (500) Inverted Flatboard.Guidance for specification option: A range of flat, high-performance, rigid extruded polystyrene insulation boards.
|
Water control layer | Bauder JFRI WFRL.Guidance for specification option: Supplied as part of the JFRI Inverted Insulation system to minimize water flow through and below the insulation.
Bauder XPS WFRL.Guidance for specification option: Supplied as part of the XPS Inverted Insulation system to minimize water flow through and below the insulation.
|
System accessories | Bauder Thermoplan TL FPO Detailing Membrane.Guidance for specification option:
BauderFPO IE/AE corners.Guidance for specification option:
BauderFPO VBL 14 Laminated Metal.Guidance for specification option:
Bauder Single Ply Lighting Conductor Clips.Guidance for specification option:
BauderFPO ABL-R 75 / 110 / 160 vertical outlets.Guidance for specification option:
Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, please contact Bauder Technical Department.
BauderSYN KFK-R UNI universal leaf guard for vertical outlets.Guidance for specification option: A universal leaf guard, compatible with Thermoplan Rigid FPO rainwater outlets for preventing debris from blocking the outlet.
This Bauder Leaf Guard is designed to fit into Bauder Rigid FPO rainwater outlets. For information on non-standard sizes and refurbishment applications, please contact Bauder Technical Department. Bauder Thermoplan Stainless Steel rainwater outlets.Guidance for specification option: A high-performance stainless steel outlet, with factory-installed Thermoplan membrane flange. Supplied with an O-ring and a wire ball leaf grill.
Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, please contact Bauder Technical Department.
BauderFPO DSP-R 90 parapet outlet, DN 80 (90mm).Guidance for specification option: A rigid FPO parapet rainwater outlet, enabling Thermoplan membrane to be welded to the flange plate. UV-stable throughout. The unbacked Thermoplan membrane should be heat-welded up to the aperture to ensure colour consistency on the roof.
Bauder outlets are sized to show the internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, please contact Bauder Technical Department. BauderFPO NLF-R 63 emergency overflow.Guidance for specification option:
BauderSOLAR F Photovoltaic Mounting System.Guidance for specification option: Bauder Flat roof PV mounting solution for framed solar modules. The mounting units are secured to the roof using a membrane-to-membrane welding technique. This installation method means that the roof is not compromised by penetrations for fixings, nor is it ballasted, which would add additional weight loading to the roof. Specifically designed to be installed on Bauder bituminous or single-ply waterproofing systems and provide a lightweight, low-risk and quick-to-install mounting solution for framed solar modules. Bauder LiquiFIBRE Detailing Kit.Guidance for specification option: Fast-curing waterproofing resin, containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen-free. Bauder LiquiDETAIL.Guidance for specification option: Cold liquid-applied, fast-curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of a catalyst to trigger curing and is solvent, isocyanate and halogen-free. Bauder rooflights/ glazing/ ventilation.Guidance for specification option: All these glazing products are fully compatible with the roof waterproofing systems. Consult Bauder for details and insert requirements.
Hard landscaping/ Ballast.Guidance for specification option: Consult Bauder for information. None. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 1 |