NBS Source
I'm a manufacturer
Compare variants

AluK GT55 TB Thermally Broken Commercial Door System

Verified by manufacturer 3 months ago

Single leaf: Anodized.

AluK (GB) Ltd Variant:

Thermally broken aluminium commercial door system.

Jump to:
+44 (0)1291 639739 Website

Application

Suitable for use with medium-high traffic commercial new build and refurbishment projects.

Description

Thermally broken aluminium commercial door system.


Features and benefits:

  • Can be fully customized in terms of security, weather and functionality with thermally broken profile options.
  • Aluminium profiles are extruded in accordance with BS EN 12020, and are manufactured from grade 6060/6063 T6 aluminium.
  • Compliant with ADL1/ ADL2 capable of achieving U-values of 1.1 W/m²K.
  • A variety of powder coated colours are available in accordance with BS 6496 and BS EN 12206-1:2004. Powder coating is applied to a Qualicoat standard, utilizing an inline flash anodizing pre-treatment process, with the polyester powder coating applied within 30 minutes of the flash anodizing process to ensure suitable adhesion.
  • Doors can be dual coloured, textured or have an anodized finish.

General information

Color

Other

Guidance for specification option:

Insert RAL colour requirement or type 'Not applicable' for anodized.

Finish

Anodized

Guidance for specification option:

Anodized to a minimum 15 micrometres thickness.

Polyester powder coated

Guidance for specification option:

Polyester powder coated to a minimum 60 micrometres thickness.

Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee.

Material

Aluminium

Glass

Shape

Rectangle

Width

1200 mm

Guidance for specification option:

Single door (tested limits).

1250 mm

Guidance for specification option:

Single door (hardware limits).

2000 mm

Guidance for specification option:

Double door (tested limits).

2500 mm

Guidance for specification option:

Double door (hardware limits).

Manufacturer guidance

Recommended size limits (maximum).

Height

2200 mm

Guidance for specification option:

Single door (tested limits).

Double door (tested limits).

2400 mm

Guidance for specification option:

Single door (hardware limits).

Double door (hardware limits).

Manufacturer guidance

Recommended size limits (maximum).

Uniclass

Ss_25_10_20_90 Unitized curtain walling systemsPrimary

CAWS

L10/56 Glazed screen system

L10/560 Glazed screen system

L20/480 Doorsets

L20/55 Doorsets

Product range

Ground Floor Treatment

Specification data - Unitized curtain walling systems

Framing

-

Framing members

Aluminium curtain wall frame sections.

Cladding units

-

Glass units

Glass panels.

Guidance for specification option:

24—40 mm glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing.

Glazing.

Guidance for specification option:

24—40 mm insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door).

Infill panels.

Guidance for specification option:

24—40 mm insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core.

Panels and facings

-

Material

Aluminium infill panels.

System accessories

Not required.

GT659.

Guidance for specification option:

Single ramp low threshold.

GT660.

Guidance for specification option:

Low threshold.

GT661.

Guidance for specification option:

Double ramp low threshold.

Midrail.

Guidance for specification option:

Insert requirements.

Sidelight.

Guidance for specification option:

Insert requirements.

Fanlight.

Guidance for specification option:

Insert requirements.

Execution

Curtain wall assembly and erection.

System completion

Verification of performance.

Product Reference

AluK GT55 TB Thermally Broken Commercial Door System

Outer frame

GT202.

Guidance for specification option:

Deep pocket frame.

GT211.

Guidance for specification option:

Sill frame.

GT320.

Guidance for specification option:

DB transom.

GT324.

Guidance for specification option:

Header bar.

GT325.

Guidance for specification option:

Auto door header bar.

Vent

GT524.

Guidance for specification option:

Anti-finger trap adaptor.

GT600.

Guidance for specification option:

Standard top rail.

GT604.

Guidance for specification option:

Standard bottom rail.

GT620.

Guidance for specification option:

Locking stile.

GT622.

Guidance for specification option:

Anti-finger trap hinge stile.

Show more

Sub sill

Not required.

GT218.

Guidance for specification option:

Standard sub sill.

Configuration

Single, bi-directional - hold open.

Single, bi-directional - non hold open.

Type

Anodized.

Guidance for specification option:

To a minimum 15 micrometres thickness.

Manufacturer guidance

Finish exterior.

Texture

Not applicable.

Manufacturer guidance

Finish exterior.

Colour

Anodized.

Manufacturer guidance

Finish exterior.

Type

Anodized.

Guidance for specification option:

To a minimum 15 micrometres thickness.

Manufacturer guidance

Finish interior.

Texture

Not applicable.

Manufacturer guidance

Finish interior.

Colour

Anodized.

Manufacturer guidance

Finish interior.

Ironmongery

Electronic access locking.

Guidance for specification option:

Insert requirements.

Electronic access panic door (Dorma).

Guidance for specification option:

Insert requirements.

Manual locking.

Guidance for specification option:

Insert requirements.

Panic door (Dorma).

Guidance for specification option:

Insert requirements.

Panic door (Sentinel).

Guidance for specification option:

Insert requirements, not available with double door.

FrameDepth

110 mm.

Bead

Square.

Panel weight

110 kg.

Manufacturer guidance

Recommended weight limits (maximum): per leaf.

Size:

1250 x 2400 mm.

Guidance for specification option:

Recommended size limits (maximum): Single door (w x h): (hardware limits).

1200 x 2200 mm.

Guidance for specification option:

Recommended size limits (maximum): Single door (w x h): (tested limits).

As schedule.

Guidance for specification option:

Insert requirements.

As drawing.

Guidance for specification option:

Insert requirements.

Sustainability data

Country of product manufacture

United Kingdom

Similar products from AluK (GB) Ltd

AluK GT55 NI Non-thermally Broken Commercial Door System

AluK GT55 NI Non-thermally Broken Commercial Door System

AluK GT55 NI Non-thermally Broken Ground Floor Treatment System

AluK GT55 NI Non-thermally Broken Ground Floor Treatment System

AluK GT55 TB Thermally Broken Ground Floor Treatment System