NBS Source
AluK GT55 TB Thermally Broken Commercial Door System
Compare variants

AluK GT55 TB Thermally Broken Commercial Door System

Single leaf: Anodized.

AluK (GB) Ltd Variant:
Third party certifications:
  • Secured By Design

    Secured By Design

    Certificate type

  • QA Certificate

    QA Certificate

    Certificate type

Thermally broken aluminium commercial door system.

Jump to:
+44 (0)1291 639739 uk.aluk.com

Application

Suitable for use with medium-high traffic commercial new build and refurbishment projects.

Description

Thermally broken aluminium commercial door system.


Features and benefits:

  • Can be fully customized in terms of security, weather and functionality with thermally broken profile options.
  • Aluminium profiles are extruded in accordance with BS EN 12020, and are manufactured from grade 6060/6063 T6 aluminium.
  • Compliant with ADL1/ ADL2 capable of achieving U-values of 1.1 W/m²K.
  • A variety of powder coated colours are available in accordance with BS 6496 and BS EN 12206-1:2004. Powder coating is applied to a Qualicoat standard, utilizing an inline flash anodizing pre-treatment process, with the polyester powder coating applied within 30 minutes of the flash anodizing process to ensure suitable adhesion.
  • Doors can be dual coloured, textured or have an anodized finish.

General information

Color

Other

Insert RAL colour requirement or type 'Not applicable' for anodized.

Finish

Anodized

Anodized to a minimum 15 micrometres thickness.

Polyester powder coated

Polyester powder coated to a minimum 60 micrometres thickness.

Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee.

Material

Aluminium

Glass

Shape

Rectangle

Width

Recommended size limits (maximum).

1200 mm

Single door (tested limits).

1250 mm

Single door (hardware limits).

2000 mm

Double door (tested limits).

2500 mm

Double door (hardware limits).

Height

Recommended size limits (maximum).

2200 mm

Single door (tested limits).

Double door (tested limits).

2400 mm

Single door (hardware limits).

Double door (hardware limits).

Uniclass

Ss_25_10_20_90 Unitized curtain walling systemsPrimary

CAWS

null Glazed screen system

L10/560 Glazed screen system

L20/480 Doorsets

L20/55 Doorsets

Product range

Ground Floor Treatment

Specification data - Unitized curtain walling systems Enhanced data

Framing

-

Framing members

Aluminium curtain wall frame sections.

Cladding units

-

Glass units

Glass panels.

24—40 mm glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing.

Glazing.

24—40 mm insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door).

Infill panels.

24—40 mm insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core.

Panels and facings

-

Material

Aluminium infill panels.

System accessories

Not required.

GT659.

Single ramp low threshold.

GT660.

Low threshold.

GT661.

Double ramp low threshold.

Midrail.

Insert requirements.

Sidelight.

Insert requirements.

Fanlight.

Insert requirements.

Execution

Curtain wall assembly and erection.

System completion

Verification of performance.

Product Reference

AluK GT55 TB Thermally Broken Commercial Door System

Outer frame

GT202.

Deep pocket frame.

GT211.

Sill frame.

GT320.

DB transom.

GT324.

Header bar.

GT325.

Auto door header bar.

Vent

GT524.

Anti-finger trap adaptor.

GT600.

Standard top rail.

GT604.

Standard bottom rail.

GT620.

Locking stile.

GT622.

Anti-finger trap hinge stile.

Show more

Sub sill

Not required.

GT218.

Standard sub sill.

Configuration

Single, bi-directional - hold open.

Single, bi-directional - non hold open.

Type

Finish exterior.

Anodized.

To a minimum 15 micrometres thickness.

Texture

Finish exterior.

Not applicable.

Colour

Finish exterior.

Anodized.

Type

Finish interior.

Anodized.

To a minimum 15 micrometres thickness.

Texture

Finish interior.

Not applicable.

Colour

Finish interior.

Anodized.

Ironmongery

Electronic access locking.

Insert requirements.

Electronic access panic door (Dorma).

Insert requirements.

Manual locking.

Insert requirements.

Panic door (Dorma).

Insert requirements.

Panic door (Sentinel).

Insert requirements, not available with double door.

FrameDepth

110 mm.

Bead

Square.

Panel weight

Recommended weight limits (maximum): per leaf.

110 kg.

Size:

1250 x 2400 mm.

Recommended size limits (maximum): Single door (w x h): (hardware limits).

1200 x 2200 mm.

Recommended size limits (maximum): Single door (w x h): (tested limits).

As schedule.

Insert requirements.

As drawing.

Insert requirements.

Environmental information

Country of product manufacture

United Kingdom

Third party certifications

Secured By Design

Secured By Design

Secured by Design - certificate

QA Certificate

QA Certificate

BM Trada: Q Mark PAS 24

Similar products from AluK (GB) Ltd

AluK GT55 NI Non-thermally Broken Commercial Door System

AluK GT55 NI Non-thermally Broken Commercial Door System

AluK GT55 NI Non-thermally Broken Ground Floor Treatment System

AluK GT55 NI Non-thermally Broken Ground Floor Treatment System

AluK GT55 TB Thermally Broken Ground Floor Treatment System

AluK GT55 TB Thermally Broken Ground Floor Treatment System