Fixed Light: Anodized.
Secured By Design
Certificate type
QA Certificate
Certificate type
Aluminium open out casement window.
Suitable for use with residential new build and refurbishment projects.
Aluminium open out casement window.
Features and benefits:
Color | Other Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized To a minimum 15 micrometres thickness. Polyester powder coated Polyester powder coated to a minimum 60 micrometres thickness. Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee. |
Material | Aluminium Glass |
Shape | Rectangle |
SizeRecommended size limits (maximum). | - |
Width | 1750 mm |
Height | 1750 mm |
Uniclass | |
CAWS | L10/25 Aluminium windows L10/330 Aluminium windows |
Product range |
Dimensions and configurations | Fixed light. |
Product performance | - |
Weather performance | - |
Air permeability | Class 3 (600 Pa). |
Watertightness | Class 8A (450 Pa). |
Resistance to wind load | E2400 (2400 Pa). |
Safety | - |
Security level | Secured by design certification and to PAS 24. |
Thermal | - |
Whole window U-value | 1.4 W/m²K. |
British Fenestration Rating Council Window Energy Rating | A.In accordance with BFRC regulations including BS EN ISO 10077-2, 58BW Internal Glazed Commercial Windows can achieve: Window Energy Rating - ’A’. |
Frame | - |
Finish as delivered | - |
Coating | Anodized. |
Colour | Anodized. |
Film thickness (minimum) | 15 micrometres. |
Ventilator | Not required.AW610.Externally glazed chamfered vent. AW611.Externally glazed chamfered vent. AW613.Externally glazed ovolo vent. AW616.Internally glazed chamfered vent. AW618.Internally glazed ovolo vent. AW620.Internally glazed flat vent. AW624.Externally glazed flat vent. |
Glazing or infill | - |
Requirements | Glass panels.28–40 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W Glazing.25–35 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.25–35 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Operation | - |
Type | Manual. |
Execution | Fixing of aluminium frames. |
Product Reference | AluK 58BW Open Out Thermally Broken Window System |
Outer frame | AW600. 70 mm chamfered slim frame. AW601. 70 mm chamfered frame. AW602. 70 mm standard ovolo frame. AW603. 58 mm odd leg frame. AW604. 58 mm slim frame. |
Bead | Chamfered. Square. |
Coupler | Not required. AW702. 15 mm coupler, for 70 mm frame. AW703. 15 mm coupler, for 58 mm frame. AW705. 26 mm coupler, for 70 mm frame. AW706. 26 mm coupler, for 58 mm frame. |
Sub sill | Not required. AW542. 150 mm sill. AW543. 177 mm sill. AW544. 190 mm sill. AW570. 96 mm stub sill. |
Texture | Not applicable. |
Ironmongery | Insert requirements.
|
Accessories | Not required. AW629. Reverse rebate adaptor, for 58 mm frame. AW712. Bay pole, for 58 mm frame. AW715. 100–120° bay pole, for 70 mm frame. AW716. 120–140° bay pole, for 70 mm frame. |
Panel weightRecommended weight limits (maximum). | Not applicable. |
Size:Recommended size limits (maximum). | 2400 x 2400 mm. Casement fixed light. As drawing. Insert reference. As schedule. Insert reference. |
Country of product manufacture | United Kingdom |
AluK 58BW Open In HI Thermally Broken Window System
AluK 58BW SA Open In Thermally Broken Student Accommodation Window System
AluK 58BW ST HI Open Out Thermally Broken Heritage Window System
AluK 77IS Concealed Open In Thermally Broken Commercial Window System
AluK 77IW Open In Thermally Broken Commercial Window System
AluK 77IWE Open Out Thermally Broken Commercial Window System
AluK C70S Open In Thermally Broken Window System
AluK C70S Open Out Thermally Broken Window System