Verified by manufacturer 10 months ago
Bottom Hung Vent: Anodized.
Secured By Design
Certificate type
QA Certificate
Certificate type
Aluminium open in casement window.
Suitable for use with residential new build and refurbishment projects.
Aluminium open in casement window.
Features and benefits:
Color | Other Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized Polyester powder coated |
Material | Aluminium Glass |
Shape | Rectangle |
WidthRecommended size limits, maximum width. | 2400 mm Fixed light. 1725 mm Tilt before turn sash. Tilt only sash. Turn only sash. |
HeightRecommended size limits, maximum height. | 2400 mm Fixed light. 2300 mm Tilt before turn sash. Tilt only sash. Turn only sash. |
Uniclass | |
CAWS | L10/25 Aluminium windows L10/330 Aluminium windows |
Product range |
Dimensions and configurations | Bottom hung vent. |
Product performance | - |
Weather performance | - |
Air permeability | Class 3 (600 Pa). |
Watertightness | Class 8A (450 Pa). |
Resistance to wind load | E2400 (2400 Pa). |
Safety | - |
Security level | Secured by Design certification and to PAS 24. |
Thermal | - |
Whole window U-value | 1.5 W/m²K. |
British Fenestration Rating Council Window Energy Rating | B.In accordance with BFRC regulations including BS EN ISO 10077-2, 58BW Internal Glazed Commercial Windows can achieve: Window Energy Rating - ’B’. |
Frame | - |
Finish as delivered | - |
Coating | Anodized. |
Colour | Anodized. |
Film thickness (minimum) | 15 micrometres. |
Ventilator | Not required.AW621.Square vent. |
Glazing or infill | - |
Requirements | Glass panels.28–40 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing. Glazing.24–40 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.28–40 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Operation | - |
Type | Manual. |
Execution | Fixing of aluminium frames. |
Product Reference | AluK 58BW Open In Thermally Broken Window System |
Outer frame | AW602. 70 mm standard ovolo frame. AW604. 58 mm slim frame. AW605. 58 mm standard frame. AW607. 70 mm deep ovolo frame. AW608. 58 mm deep head. |
Bead | Bead. Square. |
Coupler | Not required. AW702. 15 mm coupler, for 70 mm frame. AW703. 15 mm coupler, for 58 mm frame. AW705. 26 mm coupler, for 70 mm frame. AW706. 26 mm coupler, for 58 mm frame. |
Sub sill | Not required. AW542. 150 mm sill. AW543. 177 mm sill. AW544. 190 mm sill. AW570. 96 mm stub sill. |
Texture | Not applicable. |
Ironmongery | Lifetime Homes manual vents. Bottom sash position, insert requirements. Manual opening vents. Centre sash position, insert requirements. |
Accessories | Not required. AW629. Reverse rebate adaptor, for 58 mm frame. AW712. Bay pole, for 58 mm frame. AW715. 100–120° bay pole, for 70 mm frame. AW716. 120–140° bay pole, for 70 mm frame. |
Panel weightRecommended weight limits (maximum). | 100 kg. Tilt before turn sash/ Tilt only sash / Turn only sash. |
Width | Insert requirements. Recommended size limits (maximum) 1725 mm. |
Height | Insert requirements. Recommended size limits (maximum) 2300 mm. |
Country of product manufacture | United Kingdom |
AluK 58BW Open Out HI Thermally Broken Window System
AluK 58BW SA Open In Thermally Broken Student Accommodation Window System
AluK 58BW ST HI Open Out Thermally Broken Heritage Window System
AluK 77IS Concealed Open In Thermally Broken Commercial Window System
AluK 77IW Open In Window System
AluK 77IWE Open Out Window System
AluK C70S Open In Thermally Broken Window System
AluK C70S Open Out Thermally Broken Window System