Cold applied liquid membrane system for thermally insulated flat roofs.

Jump to:
+44 (0) 1942 251400 Website

Application

AlphaGuard PUMA is used for providing a durable, fast curing, waterproof coating to any new build or refurbishment flat roof.

Description

AlphaGuard PUMA is a high-performance, two-component, polyurethane modified, methyl methacrylate liquid applied membrane that is primarily specified to waterproof flat roof systems. With an extremely fast catalyst activation, AlphaGuard PUMA cures in minutes ensuring fast application times and minimal disruption to follow-on trades. AlphaGuard PUMA can be applied in low temperatures, has good elongation properties, and offers a robust long lasting surface finish.


System components include:

  • TremStik Spray Primer.
  • TremVap AVCL & Carrier Membrane.
  • TremStik PU Adhesive.
  • TremTherm Insulation.
  • AlphaGuard PUMA WP.
  • AlphaGuard PUMA 165 g reinforcement fabric.
  • AlphaGuard PUMA coloured top coat.


Features and benefits:

  • Fast catalyst activation.
  • Flame-free installation.
  • Independently certified durability of at least 25 years.
  • Seamless finish.
  • Wide application temperature range.
  • No shrinkage.
  • Application without primer to most roof substrates.
  • Easy application by brush or roller.

General information

Color

Grey

Red

Finish

Smooth

Material

Methyl methacrylate

Warranty description

25 year

Uniclass

Ss_30_40_30_43 Liquid-applied warm roof covering systemsPrimary

CAWS

J31/10 Warm deck roof coating

J31/120 Warm deck roof coating

Specification data - Liquid-applied warm roof covering systems

System performance

Guidance for specification option:

AlphaGuard PUMA systems possess a variety of independently assessed accreditations for performance such as British Board of Agrément, European Technical Assessment and a Broof(t4) fire rating under BS EN 13501-5:2016 fire classification of construction products and building elements.


AlphaGuard PUMA systems comply with the performance guidelines set out in relevant UK Building Regulations, BS 6229:2018 Flat roofs with continuously supported flexible waterproof coverings, and LRWA codes of practice.


AlphaGuard PUMA membranes also offer exceptional elongation and crack bridging properties that ensure long term durability.


Preparation

-

Horizontal work

TremStik spray-on primer.

Guidance for specification option:

A solvent based synthetic rubber primer specially developed for the effective adhesion of self-adhesive or torch applied membranes to compatible substrates.


Once spray applied with the specific applicator gun, TremStik Spray-on Primer should be touch dry within 2—3 minutes achieving a coverage rate of approximately 12 m²/L dependent on substrate porosity. Spray applied application should be undertaken 10—20 cm away from the designated substrate and with a single pass ensuring an even spread of product. Please refer to the Tremco technical data sheet for further details.

Skirtings and vertical work

As horizontal work.

Air and vapour control layer

TremVap.

Guidance for specification option:

Bituminous self-adhesive air and vapour control layer (AVCL) / carrier membrane that is reinforced with composite aluminium foil and glass fibre mat. TremVap has an extremely high vapour resistance and can provide an effective barrier against warm moisture laden air rising through the system.


The upper foil facing is polyester coated and provides an ideal substrate for TremStik polyurethane adhesives when adhering TremTherm insulation boards.


Membrane laps should be minimum 80 mm with overlaps facing down the roof slope to avoid negative laps. Rolls should be laid out perpendicular to the specified falls on the roof."

Insulation

-

Type

TremTherm PIR.

Guidance for specification option:

Commonly specified throughout the industry for applications that require lightweight and thermally efficient insulation with good compressive strength.


  • Board size: 1200 x 600 mm.
  • Compressive strength: >150 kPa at 10% compression.
  • Type: Rigid Polyisocyanurate.
  • Facing and underside: Mineral coated glass.
  • Density: 32 kg/m³.
  • Board thickness: 25 mm, 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm.
  • Thermal conductivity: 0.024–0.027 W/m·K.


TremTherm mineral wool.

Guidance for specification option:

Specified for projects that require acoustic attenuation or A2 rated fire performance (non-combustible) under BS EN 13501-1 classification.


  • Board size: 1200 x 1000 mm.
  • Compressive strength: 70 kPa at 10% compression.
  • Type: Dual density mineral wool.
  • Facing: Glass fibre fleece.
  • Underside: Unfaced.
  • Density: 160 kg/m³.
  • Board thickness: 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 185 mm.
  • Thermal conductivity: 0.039 W/m·K.


Manufacturer guidance

Flat roof thermal insulation boards manufactured from either Polyisocyanurate or Mineral Wool.


TremTherm insulation is available in various incremental thicknesses, can be designed tapered, and will achieve the design requirements of our clients or Part L Building Regulations.

Fixing

TremStik PU adhesive.

Guidance for specification option:

Insulation boards should be laid out in break bond pattern, fully supported, and with all edges closely butted together to ensure thermally continuity. When laid on metal decks with partial support, the long edges of the boards should be laid perpendicular to the crowns of the metal deck with all board joints fully supported.


Insulation boards are typically adhered using TremStik PU adhesive but in certain circumstances the boards can be mechanically secured with appropriate fasteners and pressure plates. Mechanical fixing patterns are subject to project specific wind uplift calculations.

Carrier membrane

-

Type

TremVap.

Guidance for specification option:

Bituminous self-adhesive air and vapour control layer (AVCL)/ carrier membrane that is reinforced with composite aluminium foil and glass fibre mat. TremVap will provide an ideal base layer to carry and retain the specified liquid system.


Membrane laps should be minimum 80 mm. Rolls should be laid out perpendicular to the specified falls on the roof. TremVap should be dressed 50 mm above the line of the thermal insulation or to the height of any vertical thermal breaks.

Fixing

Self-adhesive.

Guidance for specification option:

TremVap is applied to TremTherm insulation by means of the self-adhesive backing. The insulation surface must be suitably primed with TremStik Spray-on Primer prior to application.

Liquid-applied waterproofing

-

Type

AlphaGuard PUMA WP.

Guidance for specification option:

A highly elastic, fully reinforced, polyurethane modified, methyl methacrylate liquid applied membrane that cures in minutes with an advanced catalyst activation. AlphaGuard PUMA WP has exceptional elongation and crack bridging properties offering a robust waterproofing layer that can easily cope with normal levels of structural or thermal movement.


AlphaGuard PUMA WP is hand-applied in two separate coats with AlphaGuard PUMA 165g Reinforcement Fabric installed between each coat. Each coat should be applied at a rate 1.4kg/m² achieving a final waterproofing layer of 2.8 kg/m² (minimum 2 mm dry film thickness). Catalyst mixing is typically 2% by weight (20°C or below) but can be adjusted for lower ambient temperatures.

Reinforcement

AlphaGuard PUMA 165 g reinforcement fabric.

Guidance for specification option:

A strong, stitch bonded, polyester reinforcing fabric that provides enhanced strength to liquid applied membrane systems.


AlphaGuard PUMA 165g Reinforcement Fabric is applied between separate coats of AlphaGuard PUMA membrane. AlphaGuard PUMA 165g Reinforcement Fabric should be carefully embedded into the base coat, lapped by minimum of 50 mm, and laid flat without creases, air pockets or prominent fibres.

Surface treatment

AlphaGuard PUMA coloured top coat.

Guidance for specification option:

A polyurethane modified methyl methacrylate liquid coating that cures in minutes with an advanced catalyst activation. AlphaGuard PUMA Coloured Top Coat will provides a durable and long lasting finish.


AlphaGuard PUMA Coloured Top Coat is hand-applied with an application rate of 0.3-0.5 kg/m² in a single coat. Catalyst mixing is typically 2% by weight (20°C or below) but can be adjusted for lower ambient temperatures.

System accessories

TremDome.

Guidance for specification option:

A traditional domed style rooflight that includes a thermally broken insulated kerb with excellent natural light transmittance properties. TremDome rooflights come with a variety of ventilation accessories and can be operated manually or electronically. Design is subject to survey or client requirements.

TremDrain.

Guidance for specification option:

Gravity drainage outlets that have an integral membrane flange for sealing flat roof membranes. TremDrain outlets are manufactured from aluminium, are suitable for all roof types and offer excellent flow rate. Type, size, and design is subject to survey or client requirements.

TremClip.

Guidance for specification option:

Lightning protection systems are frequently installed to buildings to avoid damaging and costly lightning strikes. TremClip has a threaded securement base that includes a separate retaining clip to secure lightning conductor tape at predefined centres across the roof.

TremFlash.

Guidance for specification option:

A1 non-combustible secondary cover flashing manufactured from soft and workable zinc alloy. Primarily used as lead substitute in flat roof details such as wall chases or abutment flashing.

Ilbruck SP510.

Guidance for specification option:

General purpose low modulus sealant that is silicone free and cures to form a tack free surface. TremSeal mastic can be used to enhance the waterproofing integrity of a wide variety of detailing situations.

Manufacturer guidance

As required.

Colour:

RAL 7043 (Traffic Grey).

RAL 3001 (Signal Red) for demarcated walkways.

Third party certifications

BBA Agrément Certificate

BBA Certificate

Literature

AlphaGuard PUMA Liquid Applied Flat Roof System

AlphaGuard PUMA Liquid Applied Flat Roof System

Flat Roof Systems for Refurbishment and New Build Brochure

Flat Roof Systems for Refurbishment and New Build Brochure

Case studies

Bury St Edmunds Train Station

Bury St Edmunds Train Station

Similar products from Tremco | Roofing – a brand of Tremco CPG UK Ltd

AlphaGuard BIO Warm Roof System (20 Year Warranty)

AlphaGuard BIO Warm Roof System (20 Year Warranty)

AlphaGuard BIO Warm Roof System (25 Year Warranty)

AlphaGuard BIO Warm Roof System (25 Year Warranty)