NBS Source
Alarm-aFence®

Application

Logistics and distribution companies; power and water companies; oil refineries; high-risk applications.

Description

Combined alarm and electric fence deterrent, designed to provide a physical barrier that delivers a non-lethal electric shock and alerts the occupier of any attempted intrusion.

Features:

  • Alarm signal linked via the controller can be configured to activate sirens, lights, phone diallers, etc.
  • Delivers non-lethal electric shock.
  • Optional zoning of fence to isolate point of attempted breach.
  • Features high-tensile wires spaced at every 50–100 mm with a safe, high-voltage pulse sent down alternate wires every second.
  • Complies with all current standards, including IEC 60335 -2-76.
  • Installation and annual maintenance contracts available.
  • All systems are checked by manufacturer's in-house technicians to make sure that they comply with Jacksons' Code of Practice. Subject to a satisfactory check, a certificate of compliance is issued.
  • System activates 60 times a minute to maintain security.
  • Low incidence of false alarms.
  • Can be installed in almost any situation: can be attached to the top of most existing perimeter fences, walls and sliding/ swing gates.
  • Low maintenance and operating costs.
  • Manufacturer recommends that 'Danger' signs are used every 8–10 m and change in direction along a fence line, incorporating security extras; capable of causing injury even through misuse.

Application:

Logistics and distribution companies; power and water companies; oil refineries; high-risk applications.

General information

Size

Insert requirements.

Features

Alarm signal linked via the controller can be configured to activate sirens, lights, phone diallers, etc

Delivers non-lethal electric shock

Optional zoning of fence to isolate point of attempted breach

Features high-tensile wires spaced at every 50–100 mm with a safe, high-voltage pulse sent down alternate wires every second

Complies with all current standards, including IEC 60335 -2-76

Show more

Finish

Manufacturer's standard

Material

Manufacturer's standard

Shape

Rectangular

Uniclass 2015

Ss_25_14_67_28 Electric security fencing systemsPrimary

CAWS

Q40/160 Electric security fencing

Q40/30 Proprietary fencing

Q40/430 Proprietary fencing

Specification data - Electric security fencing systems

Product Reference

Alarm-aFence®

Size

Insert requirements.

Standard

BS EN 1722-17

Wire

High-tensile

Energizer

12-volt lead acid battery

Siren output

12 V d.c.

Strobe output

12 V d.c.

Charging voltage

18 V a.c.

Power consumption

10 W

Output

-

Energy

5 J

Voltage

5700 V

Standard product features

Colour:

Manufacturer's standard.

Features:

Can be attached to existing fences; delivers non-lethal electric shock; low maintenance.

Finish:

Manufacturer's standard.

Material:

Manufacturer's standard.

Shape: