Verified by manufacturer 10 days ago
Acti 9 Standard Distribution Board
Range of three phase distribution boards.
Suitable for standard, commercial and industrial applications for final circuit single phase or single phase and neutral low voltage distribution, typical loads serviced:
A range of three phase assemblies containing switching or protective devices (e.g. circuit breakers, Arc fault detection devices, and residual current devices) associated with one or more outgoing circuits fed from one or more incoming circuits, together with terminals for the neutral and circuit protective conductors. It may also include signaling and other control devices.
The evolution of low voltage electrical distribution continues with the demands for reliability, enhanced safety, cost reduction and connectivity ever increasing.
Through market leading innovations for over a quarter of a century, Isobar distribution boards have enabled this evolution and offered new levels of performance, several of which were the first of their kind:
Active Safety System:
Advanced notifications, diagnostics, analytics, and a compact integrated device. It gives business owners and maintenance personnel greater control over their building's electrical health and, in turn, enhances service continuity.
The Plug On Neutral & Functional Earth residual current breakers with over-current (RCBOs) bring innovation for quick and easy installation, benefits include:
Color | Cream Guidance for specification option: RAL 9001. Enclosure only. |
Shape | Rectangle |
Warranty description | 18 months |
Uniclass | |
CAWS | V90/320 Distribution boards |
Standards | To BS EN 61439-3; BS EN 60898-1; BS EN 61009-1; BS EN 61008-1; BS EN 60947-2; BS EN 62606. |
Rated operational voltage (Ue) | 230/ 240 V a.c.400/ 415 V a.c. |
Incoming device | Manufacturer guidanceDependent on variant specified, consult manufacturer for details. |
Outgoing devices | |
Type | Guidance for specification option: Dependent on variant specified, consult manufacturer for details. |
Busbars and connections | |
Type | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Rated current (InA) | 250 A. |
Rated short-time withstand current (Icw) | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Neutral and earth bars | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Neutral terminations | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Spare ways | Fit with blank plates.As circuit schedules. |
Enclosure | |
Ingress protection (minimum) | To BS EN 60529, IP3X. |
Material | Steel.Guidance for specification option: Consult manufacturer for details. |
Finish | Powder paint.Guidance for specification option: Surface treatment: Epoxy. |
Colour | Cream (RAL 9001). |
Breaking capacity | 25 kA. |
Overvoltage | Category: IV. |
Rated insulation voltage | 500 V. |
Rated impulse withstand voltage | 6 kV. |
Impact resistance | IK05. |
OperationalTemperatureRange | -35 to 70°C. |
Integral accessories | Meter kit. |