NBS Source
I'm a manufacturer
Compare variants

Accordial PremierWall - Moveable Wall System

Verified by manufacturer 5 months ago

Rw 41 dB

Ash & Lacy Variant:

Acoustic sliding stacking individual panel partition.

Jump to:
+44 (0)121 525 1444 Website

Application

Suitable for a range of applications including commercial institutions, sports stadia, stores and hotels.

Description

Acoustic sliding stacking individual panel partition.

A range of extruded aluminium and cold rolled steel tracks are available to suit every project size. To make sure of durability and longevity, as standard above 51 dB our walls are fitted with welded steel frames. The choice of board finish, consisting of hardwood, chipboard or MDF core, is embedded into concealed or exposed aluminium profiles.


Features and benefits:

  • Individually operated, top hung panels, purpose made to suit any opening size up to 6 metres high.
  • Retractable top and bottom seals, able to deal with floor level differences up to 20 mm.
  • UKAS laboratory certified acoustic performance, able to achieve up to Rw 59 dB.
  • Manually operated by scissor mechanism providing 2 kN of pressure for optimal acoustic performance.
  • No unsightly floor track, to keep a clean aesthetic design.
  • Each panel is supported by low maintenance, non-deforming trolleys. Pre-sealed long life multiple bearing races to each wheel.
  • Bespoke layouts and configurations, utilizing corner panels, junction panels, pass doors, glazing cut-outs and matching recess doors for more control of design.
  • Wide variety of features and finishes.
  • UK manufactured product delivered straight from the manufacturer's Midlands-based factory.

General information

Color

White

Guidance for specification option:

Bright White.

Cream

Grey

Guidance for specification option:

Graphite.

Brown

Guidance for specification option:

Walnut, Natural Oak or Pale Oak.

Black

Finish

Matt

Woodgrain

Gloss

Primed

Laminated

Manufacturer guidance

Low and high pressure laminates are available in a selection of different textures.

Material

Aluminium

Chipboard

Steel

Laminate

Medium density fibreboard (MDF)

Length

Bespoke

Width

Bespoke

Guidance for specification option:

Maximum Individual Panel Width = 1250mm

Height

Bespoke

Guidance for specification option:

Maximum 6m Height

Warranty description

One year

Guidance for specification option:

One year manufacturer's warranty, extended to ten years with service agreement.

Uniclass

Pr_25_71_57_80 Sliding stacking panel partitionsPrimary

CAWS

L20/60 Doors

L20/545 Sliding stacking panel partitions

Specification data - Sliding stacking panel partitions

Performance

To EN ISO 140–3, Rw 41 dB.

Operation

Manually operated by scissor mechanism.

Seal pressure

2 kN.

Manufacturer guidance

Mechanical seals.

Dimensions (nominal)

-

Structural opening size

-

Manufacturer guidance

Insert requirements or refer to drawing or schedule.

Panel (average)

-

Width

-

Manufacturer guidance

Insert requirements or refer to drawing or schedule. From 650 mm up to 1250 mm as standard, wider panels possible to special order; consult manufacturer.

Height

-

Manufacturer guidance

Insert requirements or refer to drawing or schedule. From 1800 mm up to 6000 mm as standard. Higher panels possible to special order; consult manufacturer.

Thickness

100 mm.

Average panel weight

-

Standard panel

-

Manufacturer guidance

24–37 kg/m².

Track system

-

Head track

S1 – Single Point Suspension.

Guidance for specification option:

Straight runs only, panels stacked within opening. Single track, single point suspension. Four-wheel hanger.

S2 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S3 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S4 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S5 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S6 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S7 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S8 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S9 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

S10 – Double Roller Suspension.

Guidance for specification option:

For 90° movement of panels away from main track, for offset stacking. Twin point twin disc or cross roller suspension.

Manufacturer guidance

Track layout.

Park position

Single stack.

Double-ended stack.

Offset stack.

Bespoke stack.

Panels

-

Construction

Double skin cladding of 16 mm thick high-density chipboard.

Finish as delivered

Low pressure laminate from standard range.

Guidance for specification option:

Insert requirements. Available in White, Bright White, Cream, Graphite, Black, Grey, Walnut, Natural Oak, Pale Oak.

Duhospan low pressure laminate.

Guidance for specification option:

Over 30 finishes are available including 131/7 Super White, U23/6 Pastel Grey and HN312 Light Oak. Low, and a selection of different textures including Orange Peel, Matt, Pearl, Woodgrain, Nature Matt, Gloss, Satin. Consult manufacturer and insert requirements.

High pressure laminate.

Guidance for specification option:

From Altofina, Egger and Formica. Insert requirements.

Magnetic whiteboard laminate.

Guidance for specification option:

Manufacturer's colour range. RAL colours and woodgrains from Accordial house collection, as standard.

Drywipe gloss laminate.

Guidance for specification option:

Over 30 finishes are available. Consult manufacturer and insert requirements.

Real wood veneer.

Guidance for specification option:

Wide range available including American Oak, European Oak, Birch, Maple. Consult manufacturer and insert requirements.

Primed for on site decoration by others.

Guidance for specification option:

Priming sheet. Applied sheet, ready for final finish by manufacturer.

Fabric wrapped finish.

Guidance for specification option:

  • From Accordial house collection.
  • Acoustic backed textile over-cladding. With absorbent board backing. Applied on site.
  • Acoustic stretched textile over-cladding. Tensioned over frame without backing. Applied on site.

Manufacturer guidance

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

Vision panels

None.

Single glazed standard panels.

Single glazed standard panels and pass door panels.

Double glazed standard panels.

Double glazed standard panels and pass door panels.

Double glazed with internal blinds standard panels.

Double glazed with internal blinds standard panels and pass door panels.

Bespoke glazing.

Guidance for specification option:

To be confirmed.

Pass doors

Not required.

Double, inset.

Single, full height.

Single, inset.

Hardware

Not required.

With aluminium handle and black PVC backplate.

With FSB handle and recessed backplate.

Manufacturer guidance

Pass door handle.

Partition assembly

As per drawing.

Guidance for specification option:

Insert drawing number.

As per schedule.

Guidance for specification option:

Insert schedule number.

Track profile

-

Manufacturer guidance

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters. Consult manufacturer to confirm size.
  • Ceiling angle trim allows masking of suspended ceiling edge.
  • 20 mm angle trim required to avoid partition panels fouling ceiling when using single point suspension.

Track finish

Aluminium, RAL 9010.

Steel, RAL 9010.

Other.

Guidance for specification option:

Consult manufacturer for other RAL colours.

Panel Type

Standard panel NE.

Telescopic closure panel with concealed nose TE.

Guidance for specification option:

Telescopic closure panel. One TE panel required at end of run for each opening. Internal telescopic nose for visual neatness as standard, matching panel finish

Inset passdoor panel SE.

Guidance for specification option:

Single leaf inset pass door panel. Reduces overall acoustic insulation. Minimum Panel Height: 2400 mm.

Inset passdoor panel DSE.

Guidance for specification option:

Double leaf inset pass door panel. Includes head panel and jamb on hinge side of door. Reduces overall acoustic insulation. Minimum Panel Height: 2400 mm.

Full height passdoor with iamb panel set DT and TAE.

Guidance for specification option:

Full height door panel (DT). Full height hinged pass door panel. Fixed element, at end of run only. Includes jamb fixed to wall on hinge side of door. Reduces overall acoustic insulation.

Show more

Manufacturer guidance

  • Where panel type varies within the partition assembly, insert identifiers for panels after each selection.
  • Glazed panels. Glazed area to choose. Minimum margins apply. Select from: single glazed/ double glazed/ double glazed with blinds.

Fire resistance

Euro Class D boards.

Guidance for specification option:

As standard.

Euro Class C boards.

Guidance for specification option:

Surface spread of flame.

Euro Class B boards.

Guidance for specification option:

Treated non-combustible substrate board.

Panel vertical edge type

Concealed.

Guidance for specification option:

Hardwearing 2 mm thick edge banding.

Exposed.

Guidance for specification option:

Protective edge onto panel face by 7 mm.

Panel vertical edge finish

Aluminium satin anodized.

Guidance for specification option:

As standard.

Aluminium powder coated.

Guidance for specification option:

Consult manufacturer for any BS or RAL colour.

Mechanical seals

-

Manufacturer guidance

Panel clearance: 20 mm top and 25 mm bottom.

Acoustic seal

Lip, tadpole and bulb seals.

Locking

Height adjustment mechanism.

Manufacturer guidance

Carrier locking type.

Posts

Wapl: Acoustic foam adaptor.

Wal: Traditional profile post.

Colour

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Third-party certification

United Kingdom Accreditation Service (UKAS) laboratory certified acoustic performance.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom