Verified by manufacturer 1 month ago
Open-in/ Open-out
Secured By Design
Certificate type
An all-purpose, thermally broken door for use in both high traffic areas and heavy/ severe applications.
All-purpose, thermally broken door for use in both high traffic areas and heavy/ severe applications, including new build, refurbishment and heavy commercial.
Suitable for use in all public, commercial and education buildings.
An all-purpose, thermally broken door for use in both high traffic areas and heavy/ severe applications.
Fully welded construction providing exceptional strength and durability.
Available as a single leaf or double leaf butt hinge door, finger guarded pivot door or automatic sliding door.
The swing door options are also suitable for use with powered operators.
Fully independently tested to PAS 24 enhanced security with multipoint deadlocking, panic locking and with electronic access control.
With the additional benefit of the improved thermal performance from the thermally broken leaf profiles, the AA®190 TB is suitable for use in all public, commercial and education buildings.
Features and benefits:
Color | Other |
Finish | Powder-coated Anodized |
Material | Aluminium Glass |
Shape | Rectangle |
Width | Bespoke |
Height | Bespoke |
Warranty description | Lifetime Guidance for specification option: Consult manufacturer for details. |
Uniclass | |
CAWS | L20/55 Doorsets L20/480 Doorsets |
Configuration | Single-leaf, single-action.Single-leaf, double-action.Double-leaf, single-action.Double-leaf, double-action. |
Doorset size | Guidance for specification option: Consult manufacturer for options and insert requirements.
|
Performance | |
Acoustic performance | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Strength and durability | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Thermal | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details and insert details. Manufacturer guidanceU-values based on a standard single door, open out on a CEN sized door:
|
Intruder resistance | |
Minimum requirement | To PAS 24. |
Application | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Frame | |
Material | Aluminium. |
Threshold | Standard.Rebated.Guidance for specification option: Available with butt hinges only. |
Perimeter seals or inserts | Manufacturer's standard. |
Finish | |
Coating | Powder coating to BS EN 12206-1.Guidance for specification option: Consult manufacturer for options and insert requirements, including whether single or dual finish is required. Qualicoat standard. Anodizing to BS 3987.Manufacturer guidanceOver 130 standard and 31 metallic Kawneer Permacover paint finishes are available. A range of standard and coloured anodized finishes are also available. Colour samples are available on request from the manufacturer's Architectural Services Team. The finishes and coatings are covered by standard guarantees, 30 years gloss and 30 years matt and metallic and up to 25 years for anodized. Guarantees are subject to applications and Kawneer acceptance in marine, industrial, swimming pools or other aggressive atmospheres. |
Texture | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Colour | Guidance for specification option: Consult manufacturer for options and insert requirements, including multiple colours where dual finish is required. |
Door leaf | |
Thickness | Manufacturer's standard. |
Panel details | Glazed. |
Material | Aluminium frame, welded corner construction. |
Lippings | Manufacturer's standard. |
Perimeter seals | Manufacturer's standard. |
Glazing | |
Type | Double glazing.Triple glazing.Manufacturer guidanceConsult manufacturer for further options and insert requirement details. |
Manifestation | Guidance for specification option: Insert requirements or omit. |
Finish | |
Coating | As Frame.Other.Guidance for specification option: Consult manufacturer for options and insert requirements. Manufacturer guidanceOver 130 standard and 31 metallic Kawneer Permacover paint finishes are available. A range of standard and coloured anodized finishes are also available. Colour samples are available on request from the manufacturer's Architectural Services Team. The finishes and coatings are covered by standard guarantees, 30 years gloss and 30 years matt and metallic and up to 25 years for anodized. Guarantees are subject to applications and Kawneer acceptance in marine, industrial, swimming pools or other aggressive atmospheres. |
Texture | As Frame.Other.Guidance for specification option: Consult manufacturer for options and insert requirements. |
External colour | As Frame.Other.Guidance for specification option: Consult manufacturer for options and insert requirements. |
Internal colour | As External.Dual finish.Guidance for specification option: Consult manufacturer for options and insert requirements. |
Film thickness (minimum) | Manufacturer's standard. |
Door accessories | Guidance for specification option: Choice of midrails available; consult manufacturer for details and insert requirements. |
Hardware | Butt hinges.Round finger guard.Flat finger guard. |
Accessories | None.Mulit-point locking.Panic exit hardware. |
Air permeability | To BS EN 12207: 2000, Class 2 (300 Pa)*. Guidance for specification option: *Apply to Open-In Double Door with Butt Hinges and Rebated Threshold. Performance is dependant on door type and configuration, consult manufacturer for details based on requirements. |
Watertightness | To BS EN 12208: 2000, Class 3A (100 Pa)*. Guidance for specification option: *Apply to Open-In Double Door with Butt Hinges and Rebated Threshold. Performance is dependant on door type and configuration, consult manufacturer for details based on requirements. |
Wind resistance | To BS EN 12210: 2000, Class C2 (800 Pa)*. Guidance for specification option: *Apply to Open-In Double Door with Butt Hinges and Rebated Threshold. Performance is dependant on door type and configuration, consult manufacturer for details based on requirements. |
Duty | Up to Severe (UK Category of Use). Guidance for specification option: Suitable for light, medium, heavy and severe applications (UK definitions). |
Material | Aluminium Glass |
Wilfred Brown Building, Brunel University, Uxbridge
Chester Northgate
Crown Place, Norwich
Hale Wharf, London
International Convention Centre For Wales, Newport
London Screen Academy, Islington
Quayside House, Gloucester
South Central Institute of Technology, Bletchley
St Sidwell’s Point Leisure Centre, Exeter
Swiss Cottage Library, London
Taff Vale Development, Pontypridd
Tameside One, Ashton Under Lyne, Greater Manchester
The Copper House, Liverpool
The Grange University Hospital, Llanfrechfa Grange, Gwent
Uncommon Holborn, London
Unit 216, Cambridge Science Park
Victor Phillip Dahdaleh Heart and Lung Research Institute (HLRI), Cambridge
Zurich Insurance, Unity Place, Swindon