Stick-frame curtain wall system.

Jump to:
+44 (0)1928 502500 Website

Application

The AA®100 is suitable for vertical and sloped applications (down to 7°), including faceted walls.

Description

A stick-frame assembly with weather performance achieved by drainage and ventilation of the glazing rebates. Drainage and ventilation is achieved via the mullion or via each individual transom on zone drained.


Features and benefits:

  • The system is available in a variety of mullion depths with seven thermal break options, including an enhanced thermal performance option and aesthetic external capping.
  • The system has outstanding performance, and its ease of installation makes it possible to suit individual project requirements.


General information

Color

Clear

Other

Finish

Anodized

Powder-coated

Material

Aluminium

Glass

Shape

Rectangle

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_10_20_85 Stick curtain walling systemsPrimary

CAWS

H11/110 Curtain walling

Specification data - Stick curtain walling systems

Framing

-

Frame members

Aluminium curtain wall frame sections.

Frame accessories

Manufacturer's standard.

Guidance for specification option:

See Type below for system build-up, including frame accessories where relevant.

Fasteners

Guidance for specification option:

Consult manufacturer for details and insert requirements.

Cladding units

-

Glass units

Guidance for specification option:

Insert requirements, 4–50 mm glazing thickness.

Structurally silicone-glazed can accommodate 26–37 mm infill.

Glazing accessories

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Panels and facings

-

Material

Aluminium infill panels.

Thermal insulation

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Internal linings

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Fasteners

Manufacturer's standard.

Manufacturer guidance

See Type below for system build-ups.

Perimeter seals

Manufacturer's standard.

Execution

Curtain wall assembly and erection.

Design

Guidance for specification option:

Insert details as required.

Type

Fully capped and pressure-plated system.

Guidance for specification option:

The standard most commonly specified curtain wall in the Kawneer range, this variant is a fully pressure-plated, dry-glazed system that can be both zone and mullion. The comprehensive range of mullions and transoms allow facades to be designed with minimal structural support. The variety of different face caps allows the specifier to create a feature using the cap; bespoke options are available upon request.

  • Concealed drainage offering better aesthetics.
  • Maximum glazing up to 50 mm.
  • Large choice of face caps to enable total design flexibility to suite individual aesthetic requirements.
  • Bespoke face caps available (subject to approval).
  • Fire-resistant solution providing uniformity of the facade in accordance with Pr EN 1364-3, with up to 30 minutes' integrity and insulation.
  • Patented transom overlap detail which gives the uniform aesthetic finish.
  • Tested and certified in accordance with CWCT Sequence B.
  • Range of mullion, transom and face cap options with 50 mm sightlines.
  • Enhanced thermal performance to meet or exceed current Building Regulations (E&W).
  • Incorporates AA®130 Brise Soleil System.
  • Facilitates the integration of opening window products, including a concealed vent option.


Fully structurally silicone-glazed.

Guidance for specification option:

The AA®100 SSG is a system which allows glazing of the curtain walling to be achieved without the use of visible face caps, giving an aesthetically pleasing appearance with flush glazing to the exterior. It also offers the benefit of reduced on-site installation time, making the AA®100 SSG a more cost-effective solution. The glazing units are constructed with the use of structural silicone sealant, and contain an integrated channel profile around the perimeter. Toggle clips positioned on the mullions and transoms locate into the channel profile and provide the mechanical retention to secure the pane to the curtain wall. This offers a specifier the assurance and peace of mind of a guaranteed installation. The glazing unit is deadload supported by the transom, using a combination of setting blocks and glass supports, with the final aesthetics of the facade being enhanced by use of a flush seal between the glass units, by means of a UV-resistant weatherproofing silicone sealant.


  • Dry jointing method using specially designed EPDM moulding.
  • Mullion drainage only.
  • Glazing from 26–37 mm for increased design flexibility.
  • Thermal performance can meet current Building Regulations (E&W).
  • Tested and certified in accordance with CWCT Sequence B.
  • Maximized structural capability and design with a range of mullions and transoms.
  • Integration with both AA®100 and AA®110 curtain wall systems.
  • Glazing retained using a toggle system.
  • Silicone-sealed glass-to-glass joint.
  • Maximum screen height of 16 m.


Horizontally capped/ vertically silicone-glazed/ rubberized pressure plate.

Guidance for specification option:

The Horizontal/ Vertical Cap provides the specifier with the opportunity to highlight the horizontal or vertical features across the building envelope, and gives the building its individual signature. The capped section, whether it is horizontal or vertical, stays the same as with any standard capped AA100 system. The adjacent transom or mullion can be either a structural silicone joint or a low profile EPDM gasket system, creating the appearance of a glass-to-glass join.

Vertically capped/ horizontally silicone-glazed/ rubberized pressure plate.

Guidance for specification option:

The Horizontal/ Vertical Cap provides the specifier with the opportunity to highlight the horizontal or vertical features across the building envelope, and gives the building its individual signature. The capped section, whether it is horizontal or vertical, stays the same as with any standard capped AA100 system. The adjacent transom or mullion can be either a structural silicone joint or a low profile EPDM gasket system, creating the appearance of a glass-to-glass join.

Drainage

Mullion.

Guidance for specification option:

The AA100 curtain wall is to be mullion drained with drainage and ventilation slots located in the vertical pressure plate.

Transoms are to be overlapped to the mullion which incorporates an EPDM gasket to seal between mullion and transom.

Transoms are to be fitted with a ‘Batman gasket’ to maintain the drainage integrity.

Zone.

Guidance for specification option:

The AA100 curtain wall is to be zone drained with drainage and ventilation slots located in the vertical pressure plate.

Transoms are to be square cut at the ends and are to incorporate EPDM mouldings to maintain each zone or transoms are to be overlapped to the mullion and are to incorporate EPDM mouldings and gaskets to maintain each zone.

Transoms are to be fitted with a ‘Batman gasket’ to maintain the drainage integrity.

Surface finish

Guidance for specification option:

Insert requirements (finish and colour).

Manufacturer guidance

Over 130 standard and 31 metallic Kawneer Permacover™ polyester paint finishes are available. A range of standard and coloured anodized finishes are also available. Colour samples are available on request.


The finishes coatings are covered by standard guarantees; 30 years gloss, 30 years matt and metallic for Permacover™ and up to 25 years for anodized.

Guarantees are subject to application and Kawneer acceptance in marine, industrial, swimming pools or other aggressive atmospheres. 

Film thickness

Manufacturer's standard.

Guidance for specification option:

Depending on finish and application specified.

Air permeability

600 Pa.

Watertightness

Static and dynamic: 600 Pa.

Wind resistance

Serviceability: 2400 Pa.
Safety: 3600 Pa.

Thermal performance

Uf = 1.93 W/m²K (typical).

Weighted sound reduction index, Rw

48 (-2;-6) dB (typical).

Standards

Tested and assessed in accordance with BS EN 13830 and Centre for Window and Cladding Technology (CWCT) Curtain Wall Standards.

Sustainability data

Material

Aluminium

Glass

BIM objects

Platform Compatible Version
Revit
-

1

Case studies

Hale Wharf, London

Hale Wharf, London

Primrose Hill, London

Primrose Hill, London

Unit 216, Cambridge Science Park

Unit 216, Cambridge Science Park

Wilfred Brown Building, Brunel University, Uxbridge

Wilfred Brown Building, Brunel University, Uxbridge

Quayside House, Gloucester

Quayside House, Gloucester

St Sidwell’s Point Leisure Centre, Exeter

St Sidwell’s Point Leisure Centre, Exeter

Vox Development, Manchester

Vox Development, Manchester

Foss Park Hospital, York

Foss Park Hospital, York

The Copper House, Liverpool

The Copper House, Liverpool

Plot A7, The Slate Yard, Salford

Plot A7, The Slate Yard, Salford

Citylabs 2.0, Manchester

Citylabs 2.0, Manchester

Crown Place, Norwich

Crown Place, Norwich

National Automotive Innovation Centre, University of Warwick

National Automotive Innovation Centre, University of Warwick

University House, University of Birmingham

University House, University of Birmingham

Tameside One, Ashton Under Lyne, Greater Manchester

Tameside One, Ashton Under Lyne, Greater Manchester

Chester Northgate

Chester Northgate

Anna Freud Centre, London

Anna Freud Centre, London

Associated British Foods Regional HQ, Peterborough

Associated British Foods Regional HQ, Peterborough

BTR Towers, Erie Basin, Salford Quays, Manchester

BTR Towers, Erie Basin, Salford Quays, Manchester

London Screen Academy, Islington

London Screen Academy, Islington

Lowther Road Integrated Community Mental Health Centre, Islington, London

Lowther Road Integrated Community Mental Health Centre, Islington, London

Middlewood Locks, Manchester

Middlewood Locks, Manchester

Plot 6, Perry Barr Residential Scheme, Birmingham

Plot 6, Perry Barr Residential Scheme, Birmingham

South Central Institute of Technology, Bletchley

South Central Institute of Technology, Bletchley

Uncommon Holborn, London

Uncommon Holborn, London

Victor Phillip Dahdaleh Heart and Lung Research Institute (HLRI), Cambridge

Victor Phillip Dahdaleh Heart and Lung Research Institute (HLRI), Cambridge