NBS Source
I'm a manufacturer

Application

4–8 way flat interface for use on a C-TEC EVAC-ALERT system.

Description

A loop-powered 4–8 way flat interface for use on a C-TEC EVAC-ALERT system.


Features and benefits:

  • Supplied as a four circuit unit extendable to eight using a CA737PCB.
  • Provides four or eight monitored 12.5 mA sounder circuits to power up to two self-testing evacuation alert sounders per flat.
  • Includes space and connections for an optional fully monitored auxiliary 24 V 1 A CA737PSU to power additional visual indicators and/ or vibrating pillow pads.
  • Includes an onboard short circuit loop isolator.
  • Uses one loop address per four sounder circuits.
  • Sounder circuit test facility per circuit.
  • Practical and flexible device interfacing method for most new and refurb installations, the unit is particularly suitable to be mounted in a riser on each floor.
  • Maintains the independent open and short circuit monitoring of all sounder circuits.
  • Reliable hard-wired technology (for C-TEC’s position on wireless devices click here).

General information

Color

Grey

Finish

Textured

Material

PVC

Shape

Rectangle

Length

96 mm

Manufacturer guidance

Depth.

Width

380 mm

Height

235 mm

Uniclass

Pr_75_80_30_41 Interface panelsPrimary
Pr_75_80_30_28 Fire alarm input and output modules

CAWS

W90/120 Fire detection and alarm systems in domestic premises

Specification data - Interface panels

Standards

To BS 8629 and EN 61000-6-3: 2007+A1: 2011.

Accessories

Not required.

CA737PCB four way flat interface extension printed circuit board (PCB) (mounts inside CA737 enclosure).

CA737PSU 24 V 1.5 A auxiliary power supply unit (PSU) for use with CA737 (mounts inside CA737 enclosure).

BF321 EACIE panel mains keyswitch (for use with CA737PSU).

Dimensions

380 x 235 x 96 mm.

Manufacturer guidance

Width x height x depth.

Weight

1.5 kg.

Guidance for specification option:

Without batteries.

Body

PVC lid and base.

Body

RAL7035.

Ingress protection

IP30.

Guidance for specification option:

Indoor use only.

Humidity

Maximum 95% RH (non-condensing).

Operating temperature

-10°C to +40°C.

Indicator colour

Active: (steady red LED).
Polling (flashing red LED).
Fault (steady yellow LED).

Guidance for specification option:

Active - sounder circuit activated.

Polling - communication check with the control and indicating equipment (CIE).

Fault - wiring fault (open or short circuit) detected on the monitored sounder circuit.

Operating voltage

18–40 V d.c.

Guidance for specification option:

Loop powered.

24 V d.c.

Guidance for specification option:

CA737PSU powered.

Current

Quiescent current: 1.7 mA.
Alarm current: 12.5 mA.

Monitoring

27 Ω end of line (EOL) short circuit (S/C) and open circuit (O/C) monitored.

Protocols

CAST®.

CAST®-PRO.

Sustainability data

Country of product manufacture

United Kingdom

Material

PVC