Smoke curtain offering up to two hours of smoke integrity, compliant with EN 12101-1:2005 & A1:2006 standards, and CERTIFIRE certified.

Jump to:
BOS
0800 072 3444 Website

Application

Smoke curtain suitable for industrial, commercial, residential, public buildings, hospitality and cultural or historical settings

  • Airports
  • Train stations
  • Kitchen servery hatches
  • Retail units
  • Shopping malls
  • Offices
  • Leisure complex
  • Warehouse
  • Factories
  • Chemical plant
  • Hospitals
  • Care homes
  • Receptions areas
  • Schools
  • Colleges
  • Academies
  • Universities
  • Nurseries
  • Residential - high rise or large houses
  • Hotels
  • Restaurants
  • Museums
  • Libraries
  • Historical sites


Description

A smoke curtain barrier designed to control and limit the spread of smoke during a fire, helping to create clear escape routes and protect occupants by containing smoke to specific areas. This improves visibility and safety during evacuation, offering up to two hours of smoke integrity (E).

Features and benefits:

  • Self-closing.
  • Tested up to a temperature of 600°C.
  • Can be specified as fixed or automated to compartment, channel and protect escape routes from smoke.
  • Can be continuous, with no maximum width, and can be installed discreetly for low headroom requirements.
  • Maximum height up to 9000 mm.

Standards:

  • Smoke Safe (D) 120 minutes.
  • Compliant to Annex B – Cycle test.
  • Compliant to ASB 1 and ASB 3 classified.
  • Compliant to EN 12101-1:2005 & A1:2006.
  • Compliant to Annex C – Smoke Leakage to Fabric.
  • Full CE Compliance (conformity certificates on request).
  • Complies to Document Part M Building Regulations 2004.
  • CERTIFIRE Certified.

General information

Color

Silver

Other

Guidance for specification option:

RAL or BS 4800 colours.

Finish

Galvanized

Guidance for specification option:

Standard.

Powder-coated

Guidance for specification option:

Optional; insert RAL or BS 4800 colour requirement.

Material

Stainless steel

Fabric

Guidance for specification option:

Woven fabric.

Fiber-glass

Shape

Rectangle

Height

9000 mm

Manufacturer guidance

Maximum height.

Warranty description

One year

Guidance for specification option:

Comprehensive warranty.

Uniclass

Pr_25_80_79_01 Active smoke barriersPrimary

CAWS

L20/610 Roller shutters/ curtains

Product range

Fire Protection

Specification data - Active smoke barriers

Standard

To BS EN 12101-1 and A1:2006.

Category

ASB1 and ASB3.

Classification categories

D 120.

Material

Flexible, woven fibreglass and stainless steel fabric.

Manufacturer guidance

Curtain:

In many cases this is coated with intumescent silicone.

Box:

The curtain assembly comprises a box housing which includes the motorized barrel and wrapped curtain. The box is attached to channel section guides at each end – these guides are the main fixing point for the entire system.

Curtain:

The curtain is manufactured from a woven fibreglass and stainless steel fabric; in many cases this is coated with intumescent silicone.

Guide rails:

100 x 50 mm galvanized steel.

Head box:

Galvanized steel:

  • Up to 4000 mm high: 180 x 180 mm.
  • Over 4000 mm: 210 x 210 mm.

Bottom rail:

Industry-standard ‘bell’ formed from galvanized steel.

Controls

None.

Audio/ visual warning devices.

Beam sensor.

Delayed drop programme.

Emergency retract switch.

Show more

Fixing

Face.

Reveal.

Manufacturer guidance

Face or reveal fixing to steel, masonry, hardwood or fire-boarded softwood.

Operation

Electrical, single phase.

Guidance for specification option:

  • Through 24 V d.c. motor.
  • Controls: Supplied with gravity failsafe control panel with inbuilt lead-acid battery support.

Curtain colour

Charcoal.

Silver-grey.

Frame colour/ finish

Guidance for specification option:

Insert requirements.

Head box, guides and bottom rail are galvanized and can be powder coated as required to any standard RAL or BS 4800 colour.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Stainless steel

Fabric

Guidance for specification option:

Woven fabric.

Fiber-glass

Recyclability

90

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

15 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

AkzoNobel

Akzo Nobel Power coated

Alcumus SafeContractor

Alcumus Safe Contractor Certificate of Accreditation

CHAS

CHAS Certificate of Accreditation

Constructionline

Construction Line Gold Membership

dhf certificate

DHF Full Member

ISO 9001 Quality Management

ISO 9001

Certifire Certificate

Warrington Fire - Certifire

Alcumus SafeContractor

Alcumus SafeContractor

DoP

Certificate of Constancy of Performance (Fire)

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

Warringtonfire

Certificate of Constancy of Performance

Literature

Fireguard HS120

Fireguard HS120

CAD HS120

CAD HS120