Metsec SFS Infill Wall with Versaliner Sheathing Board and Siniat Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and Siniat Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and Siniat Lining

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
Product certifications

Specification

Framing members
Metsec SFS, 90 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Sheathing board
Euroform Versaliner - 12 mm.
-
-
Inner layers
Siniat Fire Board, 12.5 mm.
-
-
Face layer
Siniat Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
30/30 minutes (Insulation/ Integrity).
-
-
Internal face
60/ 60 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-
Product Reference
Metsec SFS Infill Wall
-
-

Sustainability data

A1-A3 (production stage)

Embodied carbon as defined in BS EN 15804

Normalised unit
2.8 kg CO₂ eq/kg
-
-
Declared unit
2.76 kg CO₂ eq/kg

Self-declared

-
-
Recyclability
94
-
-
Recycled content
60 %
-
-