IG Box Lintels - Standard/ Heavy/ Extra Heavy Duty
IG Box Lintels - Standard/ Heavy/ Extra Heavy Duty
IG Box Lintels - Standard/ Heavy/ Extra Heavy Duty

Verified 3 days ago

IG Lintels

Solid Wall - 150 mm

Verified 3 days ago

IG Lintels

Solid Wall - 100 mm

Verified 3 days ago

IG Lintels

Solid Wall - 200 mm

Summary
Solid Wall | BBA | Part L Compliant | UKCA | CE | Galvanized & Stainless
Solid Wall | BBA | Part L Compliant | UKCA | CE | Galvanized & Stainless
Solid Wall | BBA | Part L Compliant | UKCA | CE | Galvanized & Stainless
Application
  • Box lintels for use in internal and external cavity or solid wall construction to support walls, floors and roofs above window and door openings.
  • Solid wall construction.
  • Lintels should be installed with a minimum end bearing of 150 mm, bedded on mortar and levelled along its length and across its width.
  • The masonry above the lintel should be built in accordance with BS EN 1996-2.
  • The box lintel is designed to carry the full load of wet masonry as soon as it is installed.
  • Masonry should be laid on a mortar bed and all perpendicular joints should be filled. Allow the mortar to cure before applying floor or roof loads.
  • NHBC & LABC recommend a damp proof course (DPC) or cavity tray should be installed over all openings in external cavity walls.
  • When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position. Masonry immediately above the lintel should be allowed to cure.
  • Point loads should not be applied directly onto lintel flanges. Lintels should have a minimum of 150 mm masonry between the flange and the application level of any form of loading. Consult IG’s Technical Department if applying a point load above a lintel.
  • Do not cut lintels to length or modify them in any way without consulting an IG engineer.  
  • Masonry should not overhang any flange by more than 25 mm.  
  • Stop ends are required at each end of a lintel to prevent moisture cascading over the ends into the cavity and onto the inside wall.
  • At least two weep vents are required per opening and positioned not more than 450 mm apart. 
  • Box lintels for use in internal and external cavity or solid wall construction to support walls, floors and roofs above window and door openings.
  • Solid wall construction.
  • Lintels should be installed with a minimum end bearing of 150 mm, bedded on mortar and levelled along its length and across its width.
  • The masonry above the lintel should be built in accordance with BS EN 1996-2.
  • The box lintel is designed to carry the full load of wet masonry as soon as it is installed.
  • Masonry should be laid on a mortar bed and all perpendicular joints should be filled. Allow the mortar to cure before applying floor or roof loads.
  • NHBC & LABC recommend a damp proof course (DPC) or cavity tray should be installed over all openings in external cavity walls.
  • When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position. Masonry immediately above the lintel should be allowed to cure.
  • Point loads should not be applied directly onto lintel flanges. Lintels should have a minimum of 150 mm masonry between the flange and the application level of any form of loading. Consult IG’s Technical Department if applying a point load above a lintel.
  • Do not cut lintels to length or modify them in any way without consulting an IG engineer.  
  • Masonry should not overhang any flange by more than 25 mm.  
  • Stop ends are required at each end of a lintel to prevent moisture cascading over the ends into the cavity and onto the inside wall.
  • At least two weep vents are required per opening and positioned not more than 450 mm apart. 
  • Box lintels for use in internal and external cavity or solid wall construction to support walls, floors and roofs above window and door openings.
  • Solid wall construction.
  • Lintels should be installed with a minimum end bearing of 150 mm, bedded on mortar and levelled along its length and across its width.
  • The masonry above the lintel should be built in accordance with BS EN 1996-2.
  • The box lintel is designed to carry the full load of wet masonry as soon as it is installed.
  • Masonry should be laid on a mortar bed and all perpendicular joints should be filled. Allow the mortar to cure before applying floor or roof loads.
  • NHBC & LABC recommend a damp proof course (DPC) or cavity tray should be installed over all openings in external cavity walls.
  • When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position. Masonry immediately above the lintel should be allowed to cure.
  • Point loads should not be applied directly onto lintel flanges. Lintels should have a minimum of 150 mm masonry between the flange and the application level of any form of loading. Consult IG’s Technical Department if applying a point load above a lintel.
  • Do not cut lintels to length or modify them in any way without consulting an IG engineer.  
  • Masonry should not overhang any flange by more than 25 mm.  
  • Stop ends are required at each end of a lintel to prevent moisture cascading over the ends into the cavity and onto the inside wall.
  • At least two weep vents are required per opening and positioned not more than 450 mm apart. 
Description

All IG box lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F and Scotland’s Technical Handbook, section 6. The IG box lintel has perforations along its length acting as a plaster key. IG box lintels can be insulated. In external walls provide a damp proof course / cavity tray over all lintels.


For more detailed information applicable to a particular wall construction, contact IG Lintels Technical Department. Refer to manufacturers literature for details regarding lintel ranges, height, thickness and Uniformly Distributed Load (UDL) figures.


Performance:

Fire:

  • IG lintels have been subjected to a fire test (WARRES No. 101263) in accordance with BS 476-20 and (Report No. 508704/R) in accordance with BS EN 1363-1 at Exova Warrington Fire and achieved a one hour fire performance.

Corrosion:

  • IG’s box range of lintels are manufactured from high quality grade pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating conforming to BS EN 845-2.
  • The use of austenitic stainless steel is ideal when the life expectancy and maintenance programme of a building are key considerations.  
  • Material / coating specification in buildings exceeding three storeys in a non-aggressive environment should be limited to austenitic stainless steel (chrome nickel alloys).  
  • Material / coating specification for buildings in an aggressive environment (e.g. coastal sites) should be limited to austenitic stainless steel (molybdenum chrome nickel alloys). 

Structural:

  • The IG lintel range has safe working loads as detailed in each applicable loading table in the IG Lintels Product Guide brochure.
  • The structural performance figures within each table have been ascertained by testing in accordance with the requirements of standards BS EN 5977-2, BS EN 846-9 and BS EN 845-2.

Certification:

  • BBA Agrement certificate 05/4192 including regular assessment of production.
  • UKCA assessment of performance, system 3.
  • CE assessment of performance, system 3.
  • EN 1090-2 Execution Class 2, declaration method 1,2,3a & 3b, Certificate 14/F106 & 14/F107.
  • ISO 9001 Quality Management Systems, Certificate 18/Q059.
  • ISO 14001 Environmental Management Systems, Certificate 18/E019.


Special lintels:

IG lintels can be supplied to suit a wide range of wall types, loading scenarios and bespoke custom made specials:

  • Arch lintels,
  • Bay lintels (Square or Splayed),
  • Corner lintels,
  • Bow lintels,
  • Sunlounge lintels.

Contact IG Lintels Technical Department for further information.

Stainless steel:

  • All IG’s range of lintels can be manufactured from austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Upon request, other grades of stainless steel lintels are available conforming to BS EN 845-2.

Additional features:

  • Free scheduling and specification service.
  • IG Steel lintels have a service life commensurate with that of the building in which they are installed.
  • Feature plate.
  • Powder coating.
  • Soffit cladding.
  • Brick slip cladding. 
  • Universal arch.
  • Weep holes.
  • Stop ends.
  • Bespoke.

Contact IG Lintels Technical Department for further information.

All IG box lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F and Scotland’s Technical Handbook, section 6. The IG box lintel has perforations along its length acting as a plaster key. IG box lintels can be insulated. In external walls provide a damp proof course / cavity tray over all lintels.


For more detailed information applicable to a particular wall construction, contact IG Lintels Technical Department. Refer to manufacturers literature for details regarding lintel ranges, height, thickness and Uniformly Distributed Load (UDL) figures.


Performance:

Fire:

  • IG lintels have been subjected to a fire test (WARRES No. 101263) in accordance with BS 476-20 and (Report No. 508704/R) in accordance with BS EN 1363-1 at Exova Warrington Fire and achieved a one hour fire performance.

Corrosion:

  • IG’s box range of lintels are manufactured from high quality grade pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating conforming to BS EN 845-2.
  • The use of austenitic stainless steel is ideal when the life expectancy and maintenance programme of a building are key considerations.  
  • Material / coating specification in buildings exceeding three storeys in a non-aggressive environment should be limited to austenitic stainless steel (chrome nickel alloys).  
  • Material / coating specification for buildings in an aggressive environment (e.g. coastal sites) should be limited to austenitic stainless steel (molybdenum chrome nickel alloys). 

Structural:

  • The IG lintel range has safe working loads as detailed in each applicable loading table in the IG Lintels Product Guide brochure.
  • The structural performance figures within each table have been ascertained by testing in accordance with the requirements of standards BS EN 5977-2, BS EN 846-9 and BS EN 845-2.

Certification:

  • BBA Agrement certificate 05/4192 including regular assessment of production.
  • UKCA assessment of performance, system 3.
  • CE assessment of performance, system 3.
  • EN 1090-2 Execution Class 2, declaration method 1,2,3a & 3b, Certificate 14/F106 & 14/F107.
  • ISO 9001 Quality Management Systems, Certificate 18/Q059.
  • ISO 14001 Environmental Management Systems, Certificate 18/E019.


Special lintels:

IG lintels can be supplied to suit a wide range of wall types, loading scenarios and bespoke custom made specials:

  • Arch lintels,
  • Bay lintels (Square or Splayed),
  • Corner lintels,
  • Bow lintels,
  • Sunlounge lintels.

Contact IG Lintels Technical Department for further information.

Stainless steel:

  • All IG’s range of lintels can be manufactured from austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Upon request, other grades of stainless steel lintels are available conforming to BS EN 845-2.

Additional features:

  • Free scheduling and specification service.
  • IG Steel lintels have a service life commensurate with that of the building in which they are installed.
  • Feature plate.
  • Powder coating.
  • Soffit cladding.
  • Brick slip cladding. 
  • Universal arch.
  • Weep holes.
  • Stop ends.
  • Bespoke.

Contact IG Lintels Technical Department for further information.

All IG box lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F and Scotland’s Technical Handbook, section 6. The IG box lintel has perforations along its length acting as a plaster key. IG box lintels can be insulated. In external walls provide a damp proof course / cavity tray over all lintels.


For more detailed information applicable to a particular wall construction, contact IG Lintels Technical Department. Refer to manufacturers literature for details regarding lintel ranges, height, thickness and Uniformly Distributed Load (UDL) figures.


Performance:

Fire:

  • IG lintels have been subjected to a fire test (WARRES No. 101263) in accordance with BS 476-20 and (Report No. 508704/R) in accordance with BS EN 1363-1 at Exova Warrington Fire and achieved a one hour fire performance.

Corrosion:

  • IG’s box range of lintels are manufactured from high quality grade pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating conforming to BS EN 845-2.
  • The use of austenitic stainless steel is ideal when the life expectancy and maintenance programme of a building are key considerations.  
  • Material / coating specification in buildings exceeding three storeys in a non-aggressive environment should be limited to austenitic stainless steel (chrome nickel alloys).  
  • Material / coating specification for buildings in an aggressive environment (e.g. coastal sites) should be limited to austenitic stainless steel (molybdenum chrome nickel alloys). 

Structural:

  • The IG lintel range has safe working loads as detailed in each applicable loading table in the IG Lintels Product Guide brochure.
  • The structural performance figures within each table have been ascertained by testing in accordance with the requirements of standards BS EN 5977-2, BS EN 846-9 and BS EN 845-2.

Certification:

  • BBA Agrement certificate 05/4192 including regular assessment of production.
  • UKCA assessment of performance, system 3.
  • CE assessment of performance, system 3.
  • EN 1090-2 Execution Class 2, declaration method 1,2,3a & 3b, Certificate 14/F106 & 14/F107.
  • ISO 9001 Quality Management Systems, Certificate 18/Q059.
  • ISO 14001 Environmental Management Systems, Certificate 18/E019.


Special lintels:

IG lintels can be supplied to suit a wide range of wall types, loading scenarios and bespoke custom made specials:

  • Arch lintels,
  • Bay lintels (Square or Splayed),
  • Corner lintels,
  • Bow lintels,
  • Sunlounge lintels.

Contact IG Lintels Technical Department for further information.

Stainless steel:

  • All IG’s range of lintels can be manufactured from austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Upon request, other grades of stainless steel lintels are available conforming to BS EN 845-2.

Additional features:

  • Free scheduling and specification service.
  • IG Steel lintels have a service life commensurate with that of the building in which they are installed.
  • Feature plate.
  • Powder coating.
  • Soffit cladding.
  • Brick slip cladding. 
  • Universal arch.
  • Weep holes.
  • Stop ends.
  • Bespoke.

Contact IG Lintels Technical Department for further information.

Product certifications
Color
Silver
Silver
Silver
Finish
Galvanized, Powder-coated
Galvanized, Powder-coated
Galvanized, Powder-coated
Material
Steel, Stainless steel
Steel, Stainless steel
Steel, Stainless steel

Specification

Classification data
Standard
To BS EN 845-2.
To BS EN 845-2.
To BS EN 845-2.
Lintel type
Composite.
Composite.
Composite.
Material finish and coating reference
Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 600 g/m² (including both sides). Material Coating Ref L14., Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 275 g/m² (including both sides)., Austenitic stainless steel, grade 304 2b to BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3., Austenitic stainless steel, grade 316 2b to BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1.
Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 600 g/m² (including both sides). Material Coating Ref L14., Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 275 g/m² (including both sides)., Austenitic stainless steel, grade 304 2b to BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3., Austenitic stainless steel, grade 316 2b to BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1.
Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 600 g/m² (including both sides). Material Coating Ref L14., Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 275 g/m² (including both sides)., Austenitic stainless steel, grade 304 2b to BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3., Austenitic stainless steel, grade 316 2b to BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1.
Sizes
As Lintels schedule.
As Lintels schedule.
As Lintels schedule.
Characteristics
-
-
-
Resistance to fire
Minimum period of 60 minutes, consult IG Lintels Technical Department.
Minimum period of 60 minutes, consult IG Lintels Technical Department.
Minimum period of 60 minutes, consult IG Lintels Technical Department.
Thermal conductivity
Part L compliant.
Part L compliant.
Part L compliant.

Additional properties

Wall width
150 mm.
100 mm.
200 mm.
Duty
Standard duty., Heavy duty., Extra heavy duty.
Standard duty., Heavy duty., Extra heavy duty.
Standard duty., Heavy duty., Extra heavy duty.
Accessories
Not required., Keying options to suit required plastering applications., Feature plate., Powder coating., Soffit cladding., Brick slip cladding., Universal arch., Weep holes., Stop ends., Bespoke.
Not required., Keying options to suit required plastering applications., Feature plate., Powder coating., Soffit cladding., Brick slip cladding., Universal arch., Weep holes., Stop ends., Bespoke.
Not required., Keying options to suit required plastering applications., Feature plate., Powder coating., Soffit cladding., Brick slip cladding., Universal arch., Weep holes., Stop ends., Bespoke.

Sustainability data

Material
Steel, Stainless steel
Steel, Stainless steel
Steel, Stainless steel
Recyclability
100% Recyclable
100% Recyclable
100% Recyclable