VisionVent Manual Operation Rooflight
VisionVent Manual Operation Rooflight
VisionVent Manual Operation Rooflight

Verified 2 months ago

Glazing Vision Ltd

Double glazed: Electric

Verified 2 months ago

Glazing Vision Ltd

Triple glazed: Electric

Verified 2 months ago

Glazing Vision Ltd

Double glazed: Manual

Summary
Glazed hinged ventilation rooflight with thermally broken aluminium frame.
Glazed hinged ventilation rooflight with thermally broken aluminium frame.
Glazed hinged ventilation rooflight with thermally broken aluminium frame.
Third party certification
Digital objects
Color
Grey, White, Other
Grey, White, Other
Grey, White, Other
Finish
Polyester powder coated
Polyester powder coated
Polyester powder coated
Material
Aluminium, Glass
Aluminium, Glass
Aluminium, Glass
Shape
Rectangle
Rectangle
Rectangle

Specification

Form
Flat.
Flat.
Flat.
Size
As drawing., As schedule.
As drawing., As schedule.
As drawing., As schedule.
Frame
-
-
-
Material
Aluminium.
Aluminium.
Aluminium.
Finish
-
-
-
Coating
Polyester powder coating.
Polyester powder coating.
Polyester powder coating.
Colour
RAL 7015 slate grey and RAL 9010 white., RAL special order.
RAL 7015 slate grey and RAL 9010 white., RAL special order.
RAL 7015 slate grey and RAL 9010 white., RAL special order.
Glazing or infill
-
-
-
Type
Glass units.
Glass units.
Glass units.
Construction
Double glazed.
Triple glazed.
Double glazed.
Colour
RAL 7015 slate grey and RAL 9010 white., RAL special order.
RAL 7015 slate grey and RAL 9010 white., RAL special order.
RAL 7015 slate grey and RAL 9010 white., RAL special order.
Integral kerb
-
-
-
Operation
-
-
-
Control
Printed circuit board (PCB).
Printed circuit board (PCB).
Not required.
Accessories
Not required., BMS Integration., Enduroshield easy clean glass coating., Rain sensor., Remote control., Ritec glass coating., Thermostat.
Not required., BMS Integration., Enduroshield easy clean glass coating., Rain sensor., Remote control., Ritec glass coating., Thermostat.
Not required., Enduroshield easy clean glass coating., Ritec glass coating.
Execution
Installation of framed rooflights.
Installation of framed rooflights.
Installation of framed rooflights.

Additional properties

Seal
Inner EPDM rubber bubble seals and outer EPDM rubber seal.
Inner EPDM rubber bubble seals and outer EPDM rubber seal.
Inner EPDM rubber bubble seals and outer EPDM rubber seal.
Power supply
24 V, 14.6 A, 300 W.
24 V, 14.6 A, 300 W.
Not required.
Outer
6 mm clear soft low E toughened heat soak tested.
6 mm clear soft low E toughened heat soak tested.
6 mm clear soft low E toughened heat soak tested.
Spacer
18 mm black silicone sealed argon filled cavity.
14 mm black silicone sealed argon filled cavity (spacer 1&2).
18 mm black silicone sealed argon filled cavity.
CenterCoreSpacing
Not applicable.
6 mm clear soft low E toughened heat soak tested.
Not applicable.
Inner
8.8 mm annealed (PAR) PVB laminated.
8.8 mm annealed (PAR) PVB laminated.
8.8 mm annealed (PAR) PVB laminated.