You are viewing content for United Kingdom.

Choose a country to see content for your location. Changing region will navigate you to the homepage.

NBS Source
I'm a manufacturer

Compare variants

Standard Edging
Standard Edging
Standard Edging

Verified 18 days ago

Marshalls plc

Verified 18 days ago

Marshalls plc

Verified 18 days ago

Marshalls plc
Summary
Precast concrete edgings.
-
-
Application
  • Bullnose edging is mostly used along footpath edges.
  • Dished channels provide an aid to drainage.
  • Flat Top edging is mostly used along footpath edges.
  • Round Top edging is mostly used along footpath edges.
-
-
Description

Hydraulically pressed precast concrete edgings manufactured to BS EN 1340:2003.


Features and Benefits:

  • Durable.
  • Long-term performance.
  • Hydraulically pressed.
-
-
Finish
Textured
-
-
Material
Concrete
-
-
Shape
Rectangle
-
-
Length
915 mm
-
-
Width
50 mm
-
-
Height
150 mm
-
-
SKU Code
ED5000150, ED5000250, ED5000350, ED5100150, ED5100250, ED5100350, ED5200150, ED5200250, RK3600000, RK3640000, RK3660000
-
-

Specification

Classification data
Standard
To BS EN 1340:2003.
-
-
Physical properties
-
-
-
Finish
Textured.
-
-
Profile
-
-
-
Designation
BN.
-
-
Dimensions
50 x 150 x 914 mm., 50 x 150 x 914 mm., 50 x 200 x 914 mm., 50 x 250 x 914 mm., 75 x 230 x 914 mm., 255 x 125 mm., 50 x 150 x 914 mm., 50 x 200 x 914 mm., 50 x 200 x 914 mm., 230 x 75 mm., 50 x 250 x 914 mm.
-
-
Weathering resistance
≤1.0 kg/m² as a mean with no individual value >1.5 kg/m² (freeze thaw durability).
-
-
Abrasion resistance
≤23 mm (Wide Wheel Abrasion Test).
-
-
Unpolished Slip Resistance Value (USRV) (minimum)
>45.
-
-