NBS Source
I'm a manufacturer

Compare variants

CS Allway® GFT Series Recess Mounted Floor Joint Covers
CS Allway® GFT Series Recess Mounted Floor Joint Covers
CS Allway® GFT Series Recess Mounted Floor Joint Covers

Verified 2 months ago

Construction Specialties (UK) Ltd

Verified 2 months ago

Construction Specialties (UK) Ltd

Verified 2 months ago

Construction Specialties (UK) Ltd
Summary
Recess mounted gasketed joint covers for floor joints up to 50 mm wide, available in three frame depths to suit different floor finishes.
-
-
Application

Floor joint applications in areas where hygiene is important.

-
-
Description

Recess mounted gasketed joint covers for floor joints up to 50 mm wide. Can be fitted flush to the floor screed or left proud to butt up to a carpet or vinyl finish.


Features and benefits:

  • Choice of three frame depths to suit most floor finish types and thicknesses.
  • Mixed frame depths can be supplied.
  • Easy to clean covers for interior areas where hygiene is important.
  • Gaskets can be replaced on site and are available in 4 standard colours.
  • Joint width: up to 50 mm.
  • Horizontal movement: up to +10 mm.
  • Vertical movement: up to ±3 mm.
  • Lateral movement: up to ±3 mm.
  • Load capability: 250 kg point load.
  • Floor-to-floor and floor-to-wall configurations available.
  • Fixing:
  • Floor fixings (by others) to suit substrate at 450 mm centres and to achieve minimum 40 mm embedment.
  • Wall fixings (by others) to suit substrate at 450 mm centres.
-
-
Color
Beige, Black, Grey, White
-
-
Finish
Mill
-
-
Material
Aluminium, Thermoplastic rubber (TPR)
-
-
Warranty description
Two year
-
-

Specification

Joint width
25 mm.
-
-
Edging
-
-
-
Material
Aluminium.
-
-
Finish
Mill finish.
-
-
Colour
Silver.
-
-
Insert
-
-
-
Material
Co-extruded thermoplastic rubber (TPR).
-
-
Colour
Black., Greige., Grey., White.
-
-

Additional properties

FrameDepth
25 mm.
-
-
Barriers
Fire barrier., Acoustic barrier., Moisture barrier., Not required.
-
-
Movement
Horizontal: ±5 mm; vertical: ±3 mm; lateral: ±2 mm.
-
-
Dimensions of recess (w x h)
Minimum recess width/ depth required: 135/ 30 mm.
-
-
Dimensions (visible width)
30 mm.
-
-

Sustainability data

Material
Aluminium, Thermoplastic rubber (TPR)
-
-