NBS Source
I'm a manufacturer

Compare variants

Metsec SFS Infill Wall with Weather Defence Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Weather Defence Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Weather Defence Sheathing Board and British Gypsum Lining

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
-
-
Description

Metsec SFS infill walling forms a secondary structure which is fixed between the primary super structure at floor and soffit. It is generally positioned at the slab edge allowing insulation and external finishes to be installed continuously outside the main structural frame.


Features and benefits:

  • Quicker and easier to install than conventional deflection brackets.
  • Simpler and faster to install than traditional masonry infill.
  • Fewer components on site – less components to store, lose or work with.
  • Fix and forget system – no concerns about missing brackets.
  • Visible centre line indent indicates fixing location.
  • Vertical slots at 25 mm centres allow for flexibility of stud positions.
-
-
Product certifications
-
-

Specification

Classification data
Framing members
Metsec SFS, 240 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Outer
Rockwool Duoslab, __ mm.
-
-
Sheathing board
Siniat Weather Defence - 12 mm.
-
-
Inner layers
British Gypsum Fire Board, 12.5 mm.
-
-
Face layer
British Gypsum Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
120/ 120 minutes (Insulation/ Integrity).
-
-
Internal face
120/ 120 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-

Sustainability data

Country of product manufacture
United Kingdom
-
-
A1–A3 ('Production stage')

Embodied carbon as defined in BS EN 15804

Lower emissions

Normalized unit
2.76 kg CO₂ eq/kg
-
-
Declared unit
2.76 kg CO₂ eq/kg
-
-
Recyclability
94%
-
-
Recycled content
60 %
-
-