NBS Source
I'm a manufacturer

Compare variants

ModulAIR All-E & GreenComfort  - Exhaust Air Heat Pump
ModulAIR All-E & GreenComfort  - Exhaust Air Heat Pump
ModulAIR All-E & GreenComfort  - Exhaust Air Heat Pump

Verified 6 months ago

Joule Hot Water Systems UK Ltd

MODULAIR ALL-E & GREENCOMFORT 150 L (HMMC-PP-013)

Verified 6 months ago

Joule Hot Water Systems UK Ltd

MODULAIR ALL-E & GREENCOMFORT 180 L (HMMC-PP-014)

Verified 6 months ago

Joule Hot Water Systems UK Ltd

MODULAIR ALL-E & GREENCOMFORT 210 L (HMMC-PP-016)

Summary
Exhaust air heat pump system, providing wet central heating, domestic hot water and mechanical ventilation.
Exhaust air heat pump system, providing wet central heating, domestic hot water and mechanical ventilation.
Exhaust air heat pump system, providing wet central heating, domestic hot water and mechanical ventilation.
Digital objects
Color
White
White
White
Finish
Coated
Coated
Coated
Material
Steel, Stainless steel, Copper, Aluminium, Brass
Steel, Stainless steel, Copper, Aluminium, Brass
Steel, Stainless steel, Copper, Aluminium, Brass
Shape
Rectangle, Other
Rectangle, Other
Rectangle, Other
Width
500 mm, 545 mm, 300 mm
500 mm, 545 mm, 300 mm
500 mm, 545 mm, 300 mm
Height
700 mm, 1102 mm, 1293 mm, 1478 mm
700 mm, 1102 mm, 1293 mm, 1478 mm
700 mm, 1102 mm, 1293 mm, 1478 mm
Warranty description
Two year
Two year
Two year

Specification

Standards
-
-
-
Safety and environmental
To EN 378: 2016, EN 16147: 2017, EN 12102-1: 2017.
To EN 378: 2016, EN 16147: 2017, EN 12102-1: 2017.
To EN 378: 2016, EN 16147: 2017, EN 12102-1: 2017.
Test requirements
To BS EN 12897:2016, EN 14511-2: 2018, EN 14511-4: 2018, EN 14825: 2018.
To BS EN 12897:2016, EN 14511-2: 2018, EN 14511-4: 2018, EN 14825: 2018.
To BS EN 12897:2016, EN 14511-2: 2018, EN 14511-4: 2018, EN 14825: 2018.
Electrical safety
To EN 61000-3-11: 2019, EN 61000-3-12: 2011+A1 2021, EN 55014-1:2017+A11: 2020, EN 55014-2: 2015, EN 60335-1: 2012+A15: 2021, EN 60335-40: 2003+A13:2013.
To EN 61000-3-11: 2019, EN 61000-3-12: 2011+A1 2021, EN 55014-1:2017+A11: 2020, EN 55014-2: 2015, EN 60335-1: 2012+A15: 2021, EN 60335-40: 2003+A13:2013.
To EN 61000-3-11: 2019, EN 61000-3-12: 2011+A1 2021, EN 55014-1:2017+A11: 2020, EN 55014-2: 2015, EN 60335-1: 2012+A15: 2021, EN 60335-40: 2003+A13:2013.
Heat pump type
Exhaust.
Exhaust.
Exhaust.
Mode
Heating.
Heating.
Heating.
Coefficient of performance (minimum)
4.35/3.02 kW (COP) 4.44/3.56 kW (SCOP).
4.35/3.02 kW (COP) 4.44/3.56 kW (SCOP).
4.35/3.02 kW (COP) 4.44/3.56 kW (SCOP).
Output
-
-
-
Heating
1.45/1.31 kW.
1.45/1.31 kW.
1.45/1.31 kW.
Electrical supply type
Single phase.
Single phase.
Single phase.
Compressor
-
-
-
Type
Fixed.
Fixed.
Fixed.
Accessories
-
-
-
Refrigerant
R134a.
R134a.
R134a.

Additional properties

Dimensions
700 x 500 mm (Modul-AIR); 700 x 300 mm (GreenComfort).
700 x 500 mm (Modul-AIR); 700 x 300 mm (GreenComfort).
700 x 500 mm (Modul-AIR); 700 x 300 mm (GreenComfort).
Efficiency
A++.
A++.
A++.
Current
24 A (MCA); 32 A (MFA) (Modul-AIR).
3 A (MCA); 16 A (MFA) (GreenComfort).
24 A (MCA); 32 A (MFA) (Modul-AIR).
3 A (MCA); 16 A (MFA) (GreenComfort).
24 A (MCA); 32 A (MFA) (Modul-AIR).
3 A (MCA); 16 A (MFA) (GreenComfort).
HeatingWaterFlowRate
4.2 L min.
4.2 L min.
4.2 L min.
Power supply
230 V, 50 Hz.
230 V, 50 Hz.
230 V, 50 Hz.
Global warming potential (GWP)
1430.
1430.
1430.
HeatingCapacity
1.5/3.0/4.5 kW.
1.5/3.0/4.5 kW.
1.5/3.0/4.5 kW.
Overall sound power level
43 db.
43 db.
43 db.
Capacity
150 L.
180 L.
210 L.
Unit weight
38 kg (empty); 184.39 kg (filled).
42 kg (empty); 217.86 kg (filled).
45 kg (empty); 248 kg (filled).
Immersion
2 kW at 230 V.
2 kW at 230 V.
2 kW at 230 V.
Water pressure
10 bar.
10 bar.
10 bar.
Operating pressure (maximum)
7 bar.
7 bar.
7 bar.
Thermal insulation
PU foam.
PU foam.
PU foam.
Body
LDX 2101.
LDX 2101.
LDX 2101.
Casing
Coated mild steel.
Coated mild steel.
Coated mild steel.
Coil
316 L stainless steel.
316 L stainless steel.
316 L stainless steel.
TotalHeatLoss
1.272.
1.392.
1.488.
Cylinder
1102 x 545 mm.
1293 x 545 mm.
1478 x 545 mm.
Ventilation
-
-
-
SoundPressure
34 dB.
34 dB.
34 dB.
Ingress protection (IP) rating
IPX2.
IPX2.
IPX2.

Sustainability data

Contains Red List materials
No
No
No
Recyclability
Recycling of materials for all, or parts of the product is possible. However, the refrigerant contents of the product should always be recovered prior to processing. Recycling of the product is best completed through fragmentation where the insulation material goes to energy recovery and metals for recycling.
Recycling of materials for all, or parts of the product is possible. However, the refrigerant contents of the product should always be recovered prior to processing. Recycling of the product is best completed through fragmentation where the insulation material goes to energy recovery and metals for recycling.
Recycling of materials for all, or parts of the product is possible. However, the refrigerant contents of the product should always be recovered prior to processing. Recycling of the product is best completed through fragmentation where the insulation material goes to energy recovery and metals for recycling.