Metsec SFS Infill Wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duoslab insulation
Metsec SFS Infill Wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duoslab insulation
Metsec SFS Infill Wall with British Gypsum Glasroc X sheathing board, British Gypsum Gyproc plasterboard, Rockwool Duoslab insulation

Verified 9 days ago

Metsec (voestalpine Metsec)

Verified 9 days ago

Metsec (voestalpine Metsec)

Verified 9 days ago

Metsec (voestalpine Metsec)
Summary
Metsec SFS infill wall with British Gypsum Glasroc X sheathing board, Rockwool DuoSlab insulation, and British Gypsum Gyproc Fireline (2x12.5mm) or Wallboard (2x12.5mm) lining.
Third party certification
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-

Specification

System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineers design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Insulation
External: Rockwool Duo Slab; between framing: n/a., External: Rockwool Duo Slab; between framing: ___.
-
-
Sheathing board
British Gypsum Glasroc X - 12 mm.
-
-
Framing
Metsec SFS 200 mm stud depth.
-
-
Inner layer
British Gypsum Wall Board, 12.5 mm.
-
-
Face layer
British Gypsum Wall Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
60/ 60 minutes (insulation/ integrity).
-
-
External face
60/ 60 minutes (insulation/ integrity).
-
-
Fire performance
60 minutes (boundary wall); 60 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
Variable.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-