Metsec SFS Infill Wall with Versaliner Sheathing Board and Knauf Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and Knauf Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and Knauf Lining

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
Third party certification
Material
Steel
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Framing members
Metsec SFS, 90 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Sheathing board
Euroform Versaliner - 12 mm.
-
-
Inner layers
Knauf Fire Board, 12.5 mm.
-
-
Face layer
Knauf Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
60/ 60 minutes (Insulation/ Integrity).
-
-
Internal face
90/ 120 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-
Product Reference
Metsec SFS Infill Wall
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Embodied carbon
2.76 kg CO₂ eq/kg
-
-
Recyclability
94%
-
-
Recycled content
60 %
-
-