NBS Source
I'm a manufacturer

Compare variants

QuadCore Curved Wall Panel System
QuadCore Curved Wall Panel System
QuadCore Curved Wall Panel System

Verified 5 months ago

Kingspan Insulated Panels

Verified 5 months ago

Kingspan Insulated Panels

Verified 5 months ago

Kingspan Insulated Panels
Summary
Secret-fix wall panel system with distinctive rolling profile.
Material
Steel
-
-
Length
Bespoke
-
-
Height
83 mm, 92 mm, 98 mm, 108 mm, 112 mm, 118 mm, 126 mm, 138 mm, 158 mm, 178 mm
-
-
Warranty description
25 year, 30 year
-
-

Specification

Cladding panels
-
-
-
Panel type
Curved Wall, 45 mm.
-
-
Panel fasteners
Grade 316 austenitic stainless steel self-drilling, self-tapping primary fasteners with non-ferrous EPDM backed washer, 8 mm hexagonal heads., Grade 304 austenitic stainless steel self-drilling, self-tapping primary fasteners with non-ferrous EPDM backed washer, 8 mm hexagonal heads.
-
-
Side laps sealing
Factory applied weather seal set in rebate.
-
-
End laps sealing
Kingspan AWP filler and non-setting gun-grade, site applied at the end of each panel where flashings pass over the joint. Bridging seal across panel joint in line with AWP filler and internal air seal to be non setting gun-grade. Internal face of panel to be air sealed to perimeter supports/ flashing using 20 x 9 mm PVC foam tape.
-
-
Side lap stitching fasteners
Secondary fasteners to be grade 316 austenitic stainless steel screw and washer, low profile painted head., Secondary fasteners to be grade 304 austenitic stainless steel screw and washer, low profile painted head.
-
-
End lap stitching fasteners
Secondary fasteners to be grade 316 austenitic stainless steel screw and washer, low profile painted head., Secondary fasteners to be grade 304 austenitic stainless steel screw and washer, low profile painted head.
-
-
Continuity thermal insulation
PIR board insulation to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.
-
-
Panel joints
-
-
-
Horizontal
Male and female joint.
-
-
Vertical
Butt joint.
-
-
Cavity fire barriers
-
-
-
Vertical barriers
PIR board insulation to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.
-
-
Horizontal barriers
PIR board insulation to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.
-
-
Cavity closers
PIR board insulation to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.
-
-
Fire stops
PIR board insulation to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.
-
-
Glazing
Kingspan Day-Lite Klick.
-
-
System accessories
Mechanically fixed fin feature flashing., Scalloped flashing.
-
-