TITANE Next 75 High Traffic Commercial door
TITANE Next 75 High Traffic Commercial door
TITANE Next 75 High Traffic Commercial door

Verified 4 months ago

Technal

Titane Next 75 Door and Framing System - Entrance Door

Verified 4 months ago

Technal

Titane Next 75 Door and Framing System- EN 1125 Panic Exit Door

Verified 4 months ago

Technal

Titane Next 75 Door and Framing System - Electronic Entry Door

Summary
A commercial building aluminium door solution.
A commercial building aluminium door solution.
A commercial building aluminium door solution.
Application

Suitable for use in school and commercial environments.

Suitable for use in school and commercial environments.

Suitable for use in school and commercial environments.

Description

TITANE Next offers a blend of durability, aesthetics and functionality for high-traffic commercial spaces. Extruded with aluminium made with at least 75% recycled post-consumer scrap, it delivers thermal performance, security, and long-lasting durability. Customisable finishes and large dimensions allow it to enhance any commercial property, while its low-maintenance design ensures reliability in demanding environments.

Features and benefits:

  • Sustainable design: Made with Hydro CIRCAL 75R® as standard, and Hydro CIRCAL 100R® on request, containing 75% recycled content and 95% recyclable components, TITANE Next aligns with eco-conscious building practices while maintaining a low carbon footprint across its entire lifecycle. 
  • High performance: U-values as low as 0.79 W/m²K, weather resistance, and durability tested up to 500 000 cycles, ensuring reliable performance in high-traffic environments.
  • Versatile applications: Adaptable to various configurations, including single/ double-leaf, panic exit and electomagnetic lock setups, it suits a range of architectural and functional needs.
  • Customisable aesthetics: Concealed hardware, a variety of finish options, and the ability to accommodate large dimensions.
  • Can incorporate single or double doors and automated sliding doors, designed for entrance screens and facades where compliance with The Building Regulations (E&W) Part L is required.
  • Can be used in conjunction with Technal curtain walling, windows and doors – consult manufacturer for details.
  • Thermally broken with polyamide strips.
  • Fully weather tested.

TITANE Next offers a blend of durability, aesthetics and functionality for high-traffic commercial spaces. Extruded with aluminium made with at least 75% recycled post-consumer scrap, it delivers thermal performance, security, and long-lasting durability. Customisable finishes and large dimensions allow it to enhance any commercial property, while its low-maintenance design ensures reliability in demanding environments.

Features and benefits:

  • Sustainable design: Made with Hydro CIRCAL 75R® as standard, and Hydro CIRCAL 100R® on request, containing 75% recycled content and 95% recyclable components, TITANE Next aligns with eco-conscious building practices while maintaining a low carbon footprint across its entire lifecycle. 
  • High performance: U-values as low as 0.79 W/m²K, weather resistance, and durability tested up to 500 000 cycles, ensuring reliable performance in high-traffic environments.
  • Versatile applications: Adaptable to various configurations, including single/ double-leaf, panic exit and electomagnetic lock setups, it suits a range of architectural and functional needs.
  • Customisable aesthetics: Concealed hardware, a variety of finish options, and the ability to accommodate large dimensions.
  • Can incorporate single or double doors and automated sliding doors, designed for entrance screens and facades where compliance with The Building Regulations (E&W) Part L is required.
  • Can be used in conjunction with Technal curtain walling, windows and doors – consult manufacturer for details.
  • Thermally broken with polyamide strips.
  • Fully weather tested.

TITANE Next offers a blend of durability, aesthetics and functionality for high-traffic commercial spaces. Extruded with aluminium made with at least 75% recycled post-consumer scrap, it delivers thermal performance, security, and long-lasting durability. Customisable finishes and large dimensions allow it to enhance any commercial property, while its low-maintenance design ensures reliability in demanding environments.

Features and benefits:

  • Sustainable design: Made with Hydro CIRCAL 75R® as standard, and Hydro CIRCAL 100R® on request, containing 75% recycled content and 95% recyclable components, TITANE Next aligns with eco-conscious building practices while maintaining a low carbon footprint across its entire lifecycle. 
  • High performance: U-values as low as 0.79 W/m²K, weather resistance, and durability tested up to 500 000 cycles, ensuring reliable performance in high-traffic environments.
  • Versatile applications: Adaptable to various configurations, including single/ double-leaf, panic exit and electomagnetic lock setups, it suits a range of architectural and functional needs.
  • Customisable aesthetics: Concealed hardware, a variety of finish options, and the ability to accommodate large dimensions.
  • Can incorporate single or double doors and automated sliding doors, designed for entrance screens and facades where compliance with The Building Regulations (E&W) Part L is required.
  • Can be used in conjunction with Technal curtain walling, windows and doors – consult manufacturer for details.
  • Thermally broken with polyamide strips.
  • Fully weather tested.
Product certifications
Finish
Powder-coated, Anodized
Powder-coated, Anodized
Powder-coated, Anodized
Material
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Length
Bespoke
Bespoke
Bespoke
Width
Bespoke
Bespoke
Bespoke
Height
Bespoke
Bespoke
Bespoke
Warranty description
50 year
50 year
50 year

Specification

Classification data
Standard
External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1.
External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1.
External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1.
Configuration
Double-leaf, single-action., Double-leaf, double-action., Leaf and part-leaf, single-action., Leaf and part-leaf, double-action., Single-leaf, single-action., Single-leaf, double-action.
-
-
Performance
-
-
-
Acoustic performance
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Strength and durability
To BS EN 1191:2012, Class 7., To BS EN 1191:2012, Class 6., To BS EN 1191:2012, Class 5., To BS EN 1191:2012, Class 4., To BS EN 1192:2000, Class 1., To BS EN 1192:2000, Class 2., To BS EN 1192:2000, Class 3., To BS EN 1192:2000, Class 4.
To BS EN 1191:2012, Class 7., To BS EN 1191:2012, Class 6., To BS EN 1191:2012, Class 5., To BS EN 1191:2012, Class 4., To BS EN 1192:2000, Class 1., To BS EN 1192:2000, Class 2., To BS EN 1192:2000, Class 3., To BS EN 1192:2000, Class 4.
To BS EN 1191:2012, Class 7., To BS EN 1191:2012, Class 6., To BS EN 1191:2012, Class 5., To BS EN 1191:2012, Class 4., To BS EN 1192:2000, Class 1., To BS EN 1192:2000, Class 2., To BS EN 1192:2000, Class 3., To BS EN 1192:2000, Class 4.
Thermal
Up to 1.6 W/m²K., Up to 1.2 W/m²K.
Up to 1.6 W/m²K., Up to 1.2 W/m²K.
Up to 1.6 W/m²K., Up to 1.2 W/m²K.
Intruder resistance
-
-
-
Minimum requirement
To PAS 24., Secured by Design certification.
To PAS 24., Secured by Design certification.
To PAS 24., Secured by Design certification.
Frame
-
-
-
Material
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Threshold
Doc M compliant.
Doc M compliant.
Doc M compliant.
Perimeter seals or inserts
EPDM membranes, ≤ 250 mm width.
EPDM membranes, ≤ 250 mm width.
EPDM membranes, ≤ 250 mm width.
Finish
-
-
-
Coating
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Texture
Gloss., Matt., Satin.
Gloss., Matt., Satin.
Gloss., Matt., Satin.
Colour
Standard Technal finish.
Standard Technal finish.
Standard Technal finish.
Door leaf
-
-
-
Thickness
75 mm.
75 mm.
75 mm.
Panel details
Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges.
Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges.
Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges.
Material
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Perimeter seals
EPDM weather.
EPDM weather.
EPDM weather.
Glazing
-
-
-
Type
Insulated glass units (IGUs).
Insulated glass units (IGUs).
Insulated glass units (IGUs).
Manifestation
Not required., Required.
Not required., Required.
Not required., Required.
Beading
-
-
-
Type
Internal., External.
Internal., External.
Internal., External.
Material
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Hydro CIRCAL® Aluminium alloy 6060 T66, extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9.
Finish
-
-
-
Coating
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Powder coating to BS EN 12206-1., Anodizing to BS 3987.
Texture
Gloss., Matt., Satin.
Gloss., Matt., Satin.
Gloss., Matt., Satin.
External colour
Standard Technal finish.
Standard Technal finish.
Standard Technal finish.
Internal colour
Standard Technal finish.
Standard Technal finish.
Standard Technal finish.
Film thickness (minimum)
60 microns.
60 microns.
60 microns.
Configuration
-
Double-leaf, single-action., Leaf and part-leaf, single-action.
-
Configuration
-
-
Double-leaf, single-action., Leaf and part-leaf, single-action.

Additional properties

UK exposure category
1200 Pa.
1200 Pa.
1200 Pa.
Air permeability
To EN 14351-1+A1, Class 2 (300 Pa).
To EN 14351-1+A1, Class 2 (300 Pa).
To EN 14351-1+A1, Class 2 (300 Pa).
Watertightness
To EN 14351-1+A1, Class E3A (100 Pa).
To EN 14351-1+A1, Class E3A (100 Pa).
To EN 14351-1+A1, Class E3A (100 Pa).
Resistance to wind load
To EN 14351-1+A1, Class C3 (1200 Pa).
To EN 14351-1+A1, Class C3 (1200 Pa).
To EN 14351-1+A1, Class C3 (1200 Pa).
Louvres
Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.
Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.
Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.
Closers
Technal Part M compliant concealed overhead closers TPZ60510 with 90° hold open facility., Technal Part M compliant concealed overhead closers TPZ60511 without hold open facility.
Technal Part M compliant concealed overhead closers TPZ60510 with 90° hold open facility., Technal Part M compliant concealed overhead closers TPZ60511 without hold open facility.
Technal Part M compliant concealed overhead closers TPZ60510 with 90° hold open facility., Technal Part M compliant concealed overhead closers TPZ60511 without hold open facility.
Locking
TPZ63234 Hook bolt deadlock operated by double cylinder., TPZ63234 Hook bolt deadlock operated by cylinder thumb turn.
Technal TPZ63254 locking mechanism and panic touch bars with/ without external key access to BS EN 1125., Technal TPZ63086 locking mechanism and panic touch bars with/ without external key access to BS EN 1125., Technal TPZ63087 locking mechanism and panic touch bars with/ without external key access to BS EN 1125., Technal TPZ63267 locking mechanism and panic touch bars with/ without external key access to BS EN 1125., Technal TPZ63268 locking mechanism and panic touch bars with/ without external key access to BS EN 1125.
Electro magnetic lock TPZ.
Locking/ handles
Inactive leaf: 2-point lever handle operated mortise shoot bolts lock with internal rod TPZ63815.
Inactive leaf: 2-point lever handle operated mortise shoot bolts lock with internal rod TPZ63815.
Inactive leaf: 2-point lever handle operated mortise shoot bolts lock with internal rod TPZ63815.
Third-party certification
BM Trada Q Mark, UL, IFT.
BM Trada Q Mark, UL, IFT.
BM Trada Q Mark, UL, IFT.
FrameMaterial
Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap).
Embodied carbon: GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium.
Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap).
Embodied carbon: GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium.
Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap).
Embodied carbon: GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium.
Verification
Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2., Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor.
Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2., Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor., Provide evidence of 'ability to release' for escape doors in accordance with CE/ UKCA marking.
Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2., Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor.

Sustainability data

Contains Red List materials
No
No
No
Country of material origin
United Kingdom
United Kingdom
United Kingdom
Material
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Aluminium, Polyamide, Acrylonitrile butadiene styrene (ABS)
Carbon dioxide equivalent
Normalized unit
(kg CO₂ eq/kg)
A1–A3 ('Production stage') :
1.9
A1–A3 ('Production stage') :
1.9
A1–A3 ('Production stage') :
1.9
Declared unit

Certified

A1–A3 ('Production stage') :
1.9

Certified

A1–A3 ('Production stage') :
1.9

Certified

A1–A3 ('Production stage') :
1.9
Recyclability
95%
95%
95%
Recycled content
75 %
75 %
75 %
Expected Life
50 year
50 year
50 year