NBS Source
I'm a manufacturer

Compare variants

Catnic Thermally Broken Lintel - Heavy Duty
Catnic Thermally Broken Lintel - Heavy Duty
Catnic Thermally Broken Lintel - Heavy Duty

Verified 4 months ago

Catnic, a Tata Steel Enterprise

Verified 4 months ago

Catnic, a Tata Steel Enterprise

Verified 4 months ago

Catnic, a Tata Steel Enterprise
Summary
Thermally broken cavity wall lintels.
-
-
Application

Energy efficiency is a top priority for thermally broken lintels. Replacing traditional lintels with Catnic thermally broken lintels means that heat loss through a window head detail can be reduced by up to 96%.

In a typical four bedroom house with 1,200 square feet, the heat loss through a standard lintel can account for about 6%* of the overall heat loss through the fabric of the house. Using a Catnic thermally broken lintel reduces this to 0.25%, making it extremely effective.

Our lintels are deisgne dto support:

  • Triangulated masonry load.
  • Supporting uniformly distributed masonry load.
  • Supporting uniformly distributed timber floor and roof loads.
  • Suitable for fair faced inner leaf masonry.
  • Supports concrete floors.
  • Attic truss loads.
  • Larger span multiple truss loads.
-
-
Description

Catnic’s Thermally Broken Lintels comprises powder-coated galvanised steel components on either side of an expanded polystyrene (EPS) insulation core. The steel elements are bonded to the insulation using dedicated, heavy duty adhesive. This unique design provides a complete thermal break between the inner and outer leaves without using brackets, resulting in outstanding thermal performance – ψ (psi) value always 0.05 W/mK or less.

Catnic produce a range of thermally broken cavity wall lintels, suitable for the following cavity sizes:

  • 90–105 mm,
  • 110–125 mm,
  • 130–145 mm,
  • 150-165 mm,
  • 170-185mm,
  • 190-205mm.

Lintel features and benefits:

  • Heavy duty.
  • Duplex corrosion protection system.
  • Integral plaster key
  • Continuous insulation.
  • Industry leading linear thermal transmittance psi values of 0.03 to 0.05 W/mK.
  • Safe working loads in line with Catnic’s existing cavity wall lintels.
  • Manufactured from powder coated galvanized steel.
  • Options are available to suit cavities from 90 to 205 mm, in standard, heavy and extra heavy duty performance categories.

Lintel Safe Working Loads (SWL) and weight are dependent on lintel's length.

-
-
Product certifications
-
-
Color
Black
-
-
Finish
Powder-coated
-
-
Material
Steel
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
283 mm, 308 mm, 348 mm, 303 mm, 328 mm, 323 mm, 343 mm, 368 mm, 383 mm, 408 mm
-
-
Height
154 mm, 229 mm
-
-
SKU Code
TH90/100, TH90/125, TH110/100, TH110/125, TH130/100, TH130/125, TH150/100, TH150/125, TH170/100, TH170/125, TH190/100, TH190/125
-
-

Specification

Standard
To BS EN 845-2.
-
-
Lintel type
Single.
-
-
Material finish and coating reference
Powder coated galvanized steel.
-
-
Characteristics
-
-
-
Deflection under load
Dependent on length specified.
-
-
Mass
13.3–16.7 kg/m.
-
-
Resistance to fire
Up to 1 hour.
-
-
Thermal conductivity
0.030–0.050 W/mK.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of material origin
United Kingdom
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel
-
-
Recyclability
96%
-
-
Recycled content
17 %
-
-
Expected Life
60 year
-
-