NBS Source
I'm a manufacturer

Compare variants

Cantifix Structural Glazing
Cantifix Structural Glazing
Cantifix Structural Glazing

Verified 12 hours ago

Cantifix Ltd

Verified 12 hours ago

Cantifix Ltd

Verified 12 hours ago

Cantifix Ltd
Summary
Structural glass rooflights and structures with a clean frameless appearance.
-
-
Application

Rooflights, Walls, Facades, Floors and complete enclosures

-
-
Description

Structural glass rooflights and structures with a cleanframeless appearance.

Features and benefits:

  • Frame constructed of thermally broken (or thermally isolated) powder coated aluminium profiles with fully cleated, or welded, corners.
  • Standard clear double-glazed units with low-E coating to give a minimum centre pane U-value of 1.1 W/m²K (or 1.0 W/m²K with solar control).
  • All glass is classified as safety glass, in either toughened [HST] or heat-strengthened laminate with ground edges.
  • Secondary edge seals in silicone and with black TGI spacer bars.
  • Options include low iron glass (on non-coated panes), solar control coatings, along with acoustic or security interlayers.
-
-
Product certifications
-
-
Color
Clear, Other
-
-
Finish
Powder-coated
-
-
Material
Glass, Aluminium
-
-
Shape
Rectangle, Circle, Elliptical, Oval, Trapezium
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Classification data
Form
Multi-sided enclosure.
-
-
Size
-
-
-
Product performance
-
-
-
Whole window U-value
To BS EN 10077, 1.4 W/m²K (maximum). 1.1 W/m²K (centre pane, minimum) or 1.1 W/m²K with solar control.
-
-
Frame
-
-
-
Material
Aluminium.
-
-
Finish
-
-
-
Coating
Powder coating.
-
-
Colour
-
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-
Glazing or infill
-
-
-
Type
Toughened safety glass., Heat-strengthened laminate safety glass., Other.
-
-
Construction
Double glazed, standard., Double glazed, low iron glass., Double glazed with acoustic interlayers., Double glazed with security interlayers.
-
-
Colour
Clear.
-
-
Coating
Low-E to achieve minimum centre pane U-value of 1.1 W/m²K., Solar control to achieve minimum centre pane U-value of 1.0 W/m²K., None.
-
-
Operation
-
-
-
Type
Not applicable.
-
-
Control
Not applicable.
-
-

Additional properties

Air permeability
To BS EN 12207, AE / 900 Pa.
-
-
Resistance to wind load
To BS EN 12210, Serviceability +/-2400 Pa; Safety +/-3600 Pa.
-
-
Watertightness
To BS EN 12208, RE / 900 Pa.
-
-
Performance characteristics
CWCT classification (TN92) horizontal: Class 2 (if four-edge supported and panels <4.5 m²).
-
-

Sustainability data

Material
Glass, Aluminium
-
-