NBS Source
I'm a manufacturer

Compare variants

Optima - Mineral Tile Suspended Ceiling System
Optima - Mineral Tile Suspended Ceiling System

Verified 5 days ago

Zentia

Tegular edge profiles, 20 mm thick

Verified 5 days ago

Zentia

Vector edge profiles, 22 mm thick

Summary
Suspended ceiling system with lay-in mineral ceiling tiles with a fine textured surface and offers Class A sound absorption finish with fibre scrim.
Suspended ceiling system with lay-in mineral ceiling tiles with a fine textured surface and offers Class A sound absorption finish with fibre scrim.
Digital objects
Color
White
White
Finish
Textured
Textured
Material
Mineral fibre, Steel
Mineral fibre, Steel
Shape
Rectangle, Square
Rectangle, Square
Length
Bespoke
Bespoke
Width
Bespoke
Bespoke
Height
20 mm, 22 mm
20 mm, 22 mm
Warranty description
30 year
30 year

Specification

System performance
-
-
Ceiling support
Gridline24 joggled/butt cut, Global white., Gridline24 joggled/butt cut, Black.
Gridline24 joggled/butt cut, Global white., Gridline24 joggled/butt cut, Black.
Support fasteners
-
-
Ceiling units
600 x 600 x 20 mm tegular edge mineral tiles in Global White (2349M).
600 x 600 x 22 mm vector edge mineral tiles in Global White (2387M)., 1200 x 600 x 22 mm vector edge mineral tiles in Global White (3143M).
Barriers in ceiling void
-
-
Fire barriers
-
-
Acoustic barriers
-
-
Plenum barriers
-
-
System accessories
-
-

Additional properties

Weight
Infill units: 2.0 kg/m².
Infill units: 2.8 kg/m².
Reaction to fire
To EN 13501-1, infill units: Euroclass A2-s1, d0; support grid: Euroclass A1.
To EN 13501-1, infill units: Euroclass A2-s1, d0; support grid: Euroclass A1.
Sound absorption
Infill units, αw = 0.95(H); Class A.
Infill units, αw = 1.00(H); Class A.
Noise reduction coefficient
Infill units: 0.95.
Infill units: 0.95.
VOC emissions
Infill units: The VOC emission performance in accordance with the French labelling requirements: A.
Infill units: The VOC emission performance in accordance with the French labelling requirements: A.
Formaldehyde emissions
Infill units: To EN 13964, formaldehyde emission level E1 = Best test result possible.
Infill units: To EN 13964, formaldehyde emission level E1 = Best test result possible.
Colour (Light reflectance value (LRV)
Infill units: 87%.
Infill units: 87%.
RelativeHumidity
Infill units: 95%.
Infill units: 95%.

Sustainability data

Country of product manufacture
United States
United States
Material
Mineral fibre, Steel
Mineral fibre, Steel
Recyclability
100%
100%
Recycled content
77 %
77 %