Summary
Plasterboard partition system.

Specification

Framing
Twin Speedline 'C' Stud, braced, 50 mm.
-
-
Insulation
Acoustic partition roll, 50+50 mm.
-
-
Linings
-
-
-
Inner layers
Siniat GTEC dB Board, 15 mm.
-
-
Face layer
Siniat GTEC dB Board, 15 mm.
-
-
Fasteners
Speedline Drywall Screws.
-
-
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Putty Pads., Speedline Corner Bead Tape.
-
-
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
-
-

Additional properties

Fire resistance
To BS 476, 90/ 90 minutes (Integrity/ Insulation).
-
-
Partition height
6200 mm.
-
-
Centres
600 mm.
-
-
StrengthGrade
Severe duty.
-
-
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
-
-
Calculated weighted sound reduction index (Rw)
60 Rw dB.
-
-
Standards