nbs-symbol
NBS Source
UK
All
Sign in
Home
What's new
Browse
BIM Library
Inspiration
Collections
CPD
I'm a manufacturer
Sign in
nbs-symbol
NBS Source
Home
What's new
Browse
All categories
BIM object categories
Manufacturers
BIM Library
Discover the BIM Library
NBS Plug-in for Autodesk® Revit®
NBS BIM Object Standard
Inspiration
Collections
CPD
I'm a manufacturer
UK
Compare variants
Sustainability report
Clear all
Metsec SFS infill wall with Siniat Weather Defence sheathing board, Siniat plasterboard
Verified 8 days ago
Metsec (voestalpine Metsec)
W1-N90-S22 - 90 mm stud
Download BIM
nbs-symbol
Add to spec
Metsec SFS infill wall with Siniat Weather Defence sheathing board, Siniat plasterboard
Verified 8 days ago
Metsec (voestalpine Metsec)
Select variant..
Download BIM
nbs-symbol
Add to spec
Metsec SFS infill wall with Siniat Weather Defence sheathing board, Siniat plasterboard
Verified 8 days ago
Metsec (voestalpine Metsec)
Select variant..
Download BIM
nbs-symbol
Add to spec
Summary
Metsec SFS infill wall with Siniat Weather Defence sheathing board, and Siniat Fire Board (2x12.5 mm) lining.
-
-
Product certifications
EPD
Environmental Product Declaration EPD - SFS
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
BSI Kitemark
UKCA Certificate of Conformity of the Factory Production Control
CCPI System
CCPI Light Gauge Steel Framing Systems
-
-
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-
Specification
System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineers design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-
Additional properties
Insulation
Not required., Insulation between framing.
-
-
Sheathing board
Siniat Weather Defence - 12 mm.
-
-
Framing
Metsec SFS 90 mm stud depth.
-
-
Inner layer
Siniat GTEC Fire Board, 12.5 mm.
-
-
Face layer
Siniat GTEC Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
60/ 60 minutes (insulation/ integrity).
-
-
External face
60/ 90 minutes (insulation/ integrity).
-
-
Fire performance
60 minutes (boundary wall); 60 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
127 mm.
-
-
Sustainability data
Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-