Condair DL - Hybrid Spray / Evaporative Humidifier
Condair DL - Hybrid Spray / Evaporative Humidifier

Verified over a year ago

Condair Limited

Type A unit (with booster pump)

Verified over a year ago

Condair Limited

Type B unit (without booster pump)

Summary
Hybrid spray and evaporative, close control adiabatic humidifier.
Hybrid spray and evaporative, close control adiabatic humidifier.
Shape
Rectangle
Rectangle
Color
Silver
Silver
Size
800 x 500 x 250 mm
800 x 500 x 250 mm

Specification

Accessories
Not required., Water supply flushing valve., In-duct humidistat., Water softener., RO water treatment system., Leak monitoring., External pipe flushing set., BMS gateway board., Mounting frame for pump station and control unit., Silicon-free., Droplet eliminator.
Not required., Water supply flushing valve., In-duct humidistat., Water softener., RO water treatment system., Leak monitoring., External pipe flushing set., BMS gateway board., Mounting frame for pump station and control unit., Silicon-free., Droplet eliminator.

Additional properties

Dimensions
Central unit: 800 x 500 x 250 mm, Control unit: 450 x 315 x 190 mm.
Central unit: 800 x 500 x 250 mm, Control unit: 450 x 315 x 190 mm.
Weight
Central unit: 54 kg, Control unit: 14 kg.
Central unit: 35 kg, Control unit: 14 kg.
Performance
0–1000 kg/h.
0–1000 kg/h.
Pressure
3–7 bar.
3–7 bar.
Capacity
1.5 kg/h., 2.5 kg/h., 3.0 kg/h., 4.0 kg/h., 5.0 kg/h.
1.5 kg/h., 2.5 kg/h., 3.0 kg/h., 4.0 kg/h., 5.0 kg/h.
Quality
Reverse osmosis water: 0.5–15.0 μS/cm.
Reverse osmosis water: 0.5–15.0 μS/cm.
NominalSupplyVoltage
200–240 V a.c., 50–60 Hz (maximum 6 A).
200–240 V a.c., 50–60 Hz (maximum 6 A).
Pump control
Continuous with frequency converter.
Continuous with frequency converter.
Power consumption
55–65 VA.
55–65 VA.
Motor
Booster pump motor rating: 10 VA per 10 kg/h spray capacity (approximate), with frequency converter.
Booster pump motor rating: 10 VA per 10 kg/h spray capacity (approximate), with frequency converter.
RelativeHumidity
7 steps: ±3% RH, 15 steps: ±2% RH, 31 steps: ±2% RH.
7 steps: ±4% RH, 15 steps: ±3% RH, 31 steps: ±2% RH.
Communication hub
Remote operating and fault indication board, Modbus RTU, BACnet IP and BACnet MSTP slave mode.
Remote operating and fault indication board, Modbus RTU, BACnet IP and BACnet MSTP slave mode.
PressureDrop
40 Pa (approximate).
40 Pa (approximate).
MaximumVelocity
3 m/s., 4 m/s.
3 m/s., 4 m/s.
Filter
F7 (EU7) or better air filter quality before humidifier.
F7 (EU7) or better air filter quality before humidifier.
Maximum temperature
60°C.
60°C.