NBS Source
I'm a manufacturer

Compare variants

Metsec SFS Infill Wall with Windliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Windliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Windliner Sheathing Board and British Gypsum Lining

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
Third party certification
Finish
Galvanized
-
-
Material
Steel
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-

Specification

Framing members
Metsec SFS, 90 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Sheathing board
Knauf Windliner - 12 mm.
-
-
Inner layers
British Gypsum, 12.5 mm.
-
-
Face layer
British Gypsum, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
60/ 90 minutes (Insulation/ Integrity).
-
-
Internal face
90/ 90 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-
Product Reference
Metsec SFS Infill Wall
-
-

Sustainability data

Contains Red List materials
No
-
-
Embodied carbon
2.76 kg CO₂ eq/kg
-
-
Recyclability
94%
-
-
Recycled content
60 %
-
-