NBS Source
I'm a manufacturer

Compare variants

Rockliner - Fire Rated Column Casings
Rockliner - Fire Rated Column Casings
Rockliner - Fire Rated Column Casings

Verified today

Cryotherm Insulation Ltd

Four-sided snaplock casing (typical)

Verified today

Cryotherm Insulation Ltd

Three-sided snaplock casing (typical)

Verified today

Cryotherm Insulation Ltd

Bespoke casing

Summary
Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.
Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.
Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.
Application

For the protection of structural steel beams and columns in a range of sectors including: commercial, retail, manufacturing, food processing and education.

For the protection of structural steel beams and columns in a range of sectors including: commercial, retail, manufacturing, food processing and education.

For the protection of structural steel beams and columns in a range of sectors including: commercial, retail, manufacturing, food processing and education.

Description

Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.

Rockliner has been installed throughout the UK on projects in commercial, retail, manufacturing, food processing, education sectors. It is extensively specified to provide the correct fire rating for mezzanine floors.

The system comprises a pre-formed metal encasement lined with Spiralite to provide the fire rating. It is installed using a snap-lock method for a strong and stable installation.

Casing thicknesses vary according to the fire rating and the steel sizes. Cryotherm's technical support advises on design and lining thickness to ensure the installation is correct.

Rockliner has been independently tested and assessed by BRE to British standards in accordance with the 5th edition of the ASFP Yellow Book.

Features and benefits:

  • Extensively used with a proven track record.
  • Up to two hours' fire rating. 
  • Wide scope for protecting square hollow sections.
  • Pre-fabricated and easy to install.
  • Colour finishes and brand matching; available in galvanized, polyester and leather grain colour ranges.
  • Specialist finishes, in particular food processing areas. 
  • Fascia available via manufacturer' fabrication service.
  • Technical support and advice available.
  • Tested to British standards.

Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.

Rockliner has been installed throughout the UK on projects in commercial, retail, manufacturing, food processing, education sectors. It is extensively specified to provide the correct fire rating for mezzanine floors.

The system comprises a pre-formed metal encasement lined with Spiralite to provide the fire rating. It is installed using a snap-lock method for a strong and stable installation.

Casing thicknesses vary according to the fire rating and the steel sizes. Cryotherm's technical support advises on design and lining thickness to ensure the installation is correct.

Rockliner has been independently tested and assessed by BRE to British standards in accordance with the 5th edition of the ASFP Yellow Book.

Features and benefits:

  • Extensively used with a proven track record.
  • Up to two hours' fire rating. 
  • Wide scope for protecting square hollow sections.
  • Pre-fabricated and easy to install.
  • Colour finishes and brand matching; available in galvanized, polyester and leather grain colour ranges.
  • Specialist finishes, in particular food processing areas. 
  • Fascia available via manufacturer' fabrication service.
  • Technical support and advice available.
  • Tested to British standards.

Rockliner is a metal-faced casing system used for the protection of structural steel beams and columns.

Rockliner has been installed throughout the UK on projects in commercial, retail, manufacturing, food processing, education sectors. It is extensively specified to provide the correct fire rating for mezzanine floors.

The system comprises a pre-formed metal encasement lined with Spiralite to provide the fire rating. It is installed using a snap-lock method for a strong and stable installation.

Casing thicknesses vary according to the fire rating and the steel sizes. Cryotherm's technical support advises on design and lining thickness to ensure the installation is correct.

Rockliner has been independently tested and assessed by BRE to British standards in accordance with the 5th edition of the ASFP Yellow Book.

Features and benefits:

  • Extensively used with a proven track record.
  • Up to two hours' fire rating. 
  • Wide scope for protecting square hollow sections.
  • Pre-fabricated and easy to install.
  • Colour finishes and brand matching; available in galvanized, polyester and leather grain colour ranges.
  • Specialist finishes, in particular food processing areas. 
  • Fascia available via manufacturer' fabrication service.
  • Technical support and advice available.
  • Tested to British standards.
Color
Silver, Beige, Black, Blue, Brown, Cream, Gold, Green, Grey, Ivory, Orange, Pink, Purple, Red, Turquoise, White, Yellow, Other
Silver, Beige, Black, Blue, Brown, Cream, Gold, Green, Grey, Ivory, Orange, Pink, Purple, Red, Turquoise, White, Yellow, Other
Silver, Beige, Black, Blue, Brown, Cream, Gold, Green, Grey, Ivory, Orange, Pink, Purple, Red, Turquoise, White, Yellow, Other
Finish
Metal, Galvanized, Powder-coated, Leather effect, Other, Unfinished
Metal, Galvanized, Powder-coated, Leather effect, Other, Unfinished
Metal, Galvanized, Powder-coated, Leather effect, Other, Unfinished
Material
Metal, Stone wool, Mineral wool
Metal, Stone wool, Mineral wool
Metal, Stone wool, Mineral wool
Shape
Rectangle, Other
Rectangle, Other
Rectangle, Other
Length
Bespoke
Bespoke
Bespoke
Width
Bespoke
Bespoke
Bespoke
Height
Bespoke
Bespoke
Bespoke

Specification

Classification data
Description
Spiralite fire-rated stone wool board with pre-formed metal encasement.
Spiralite fire-rated stone wool board with pre-formed metal encasement.
Spiralite fire-rated stone wool board with pre-formed metal encasement.
Fire rating
-
-
-
Thickness
-
-
-
Edges
Square.
Square.
Square.
Finish
0.6 mm steel, unfinished (galvanized)., 0.6 mm steel, plasticol coated., 0.6 mm steel, PvF2 coated., 0.6 mm steel, powder-coated., 0.6 mm steel, polyester-coated., 0.6 mm steel, leather grain., 0.6 mm steel, food-safe finish.
0.6 mm steel, unfinished (galvanized)., 0.6 mm steel, plasticol coated., 0.6 mm steel, PvF2 coated., 0.6 mm steel, powder-coated., 0.6 mm steel, polyester-coated., 0.6 mm steel, leather grain., 0.6 mm steel, food-safe finish.
0.6 mm steel, unfinished (galvanized)., 0.6 mm steel, plasticol coated., 0.6 mm steel, PvF2 coated., 0.6 mm steel, powder-coated., 0.6 mm steel, polyester-coated., 0.6 mm steel, leather grain., 0.6 mm steel, food-safe finish.
Colour
-
-
-
Environmental information
-
-
-
Recycled content
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.

Additional properties

Fixing
Snap-lock joints (steel encasement).
Snap-lock joints (steel encasement);
Concrete screws (not supplied) at 300 mm centres through flange;
Bead of intumescent mastic (not supplied) to the flange edge and concrete.
-
Accessories
Packing-out noggins., None.
Noggins., None.
Packing-out noggins., None.
Configuration
U-shaped section with a snap-on lid., Four pieces with snap-on joints.
U-shaped section (complete)., Three pieces with snap-on joints.
-

Sustainability data

Material
Metal, Stone wool, Mineral wool
Metal, Stone wool, Mineral wool
Metal, Stone wool, Mineral wool