FAAST FLEX™ - Aspirating Smoke Detector - Aspirating Smoke Detector
FAAST FLEX™ - Aspirating Smoke Detector - Aspirating Smoke Detector

Verified 2 days ago

XTRALIS

FLX-010 (1 pipe - single channel)

Verified 2 days ago

XTRALIS

FLX-020 (2 pipes - dual channel)

Summary
Aspirating smoke detector providing a highly flexible and cost-effective solution.
Aspirating smoke detector providing a highly flexible and cost-effective solution.
Application

Suitable for a range of application areas, for example:

  • Warehouses (small to medium).
  • Refrigerated storage facilities.
  • Elevator shafts.
  • Ceiling and underfloor voids.
  • Transformer and electrical rooms.
  • Low noise environments.

Suitable for a range of application areas, for example:

  • Warehouses (small to medium).
  • Refrigerated storage facilities.
  • Elevator shafts.
  • Ceiling and underfloor voids.
  • Transformer and electrical rooms.
  • Low noise environments.
Description

Aspirating smoke detector providing a highly flexible and cost-effective solution.

FAAST FLEX™ provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.

Features and benefits:

  • Reliable smoke detection for consistent performance and minimum nuisance alarms.
  • Single and dual channel variants with area coverage up to 1600 m² for single channel and 2000 m² for dual channel.
  • Double knock capability (dual channel) for coincidence detection.
  • Pipe length up to 270 m for single channel and 420 m for dual channel allowing extended coverage and convenient detector mounting.
  • Class A, B, C performance allowing: One channel: 5, 15, 32 holes respectively; or two channels: 8, 28, 56 holes respectively.
  • An ultrasonic flow sensing element per chamber for accurate and reliable flow detection.
  • A metallic mesh filter per chamber for optics protection and improved detector longevity.
  • Action, Alarm and Fault relays per channel for connection to fire alarm control panel (FACP) and building management systems (BMS).
  • Simplified and intuitive light emitting diode (LED) user interface for immediate status indication.
  • Pre-engineered pipe networks for hassle-free and expedient design and installation.
  • Two configuration modes: Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning, or extended for enhanced user experience.
  • Modular design with in-field replaceable chamber, filter and aspirator for ease of service and maintenance.
  • Installation template, different mounting orientations (upright, inverted) and ample wiring room to save time and effort.
  • Suitable for cold storage environments with -40 °C operating temperature.
  • Bluetooth interface with mobile device App for extended configuration options and rapid diagnostics.
  • General Purpose Input (GPI) for remote Reset, Disable, External Fault.
  • Password protected access for secured detector operation, diagnostics and maintenance.
  • IP40 rating for protection against ingress of foreign bodies.
  • Onboard event log up to 2100 events for user actions and smoke trends.
  • EN54-20 Certified.

Aspirating smoke detector providing a highly flexible and cost-effective solution.

FAAST FLEX™ provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.

Features and benefits:

  • Reliable smoke detection for consistent performance and minimum nuisance alarms.
  • Single and dual channel variants with area coverage up to 1600 m² for single channel and 2000 m² for dual channel.
  • Double knock capability (dual channel) for coincidence detection.
  • Pipe length up to 270 m for single channel and 420 m for dual channel allowing extended coverage and convenient detector mounting.
  • Class A, B, C performance allowing: One channel: 5, 15, 32 holes respectively; or two channels: 8, 28, 56 holes respectively.
  • An ultrasonic flow sensing element per chamber for accurate and reliable flow detection.
  • A metallic mesh filter per chamber for optics protection and improved detector longevity.
  • Action, Alarm and Fault relays per channel for connection to fire alarm control panel (FACP) and building management systems (BMS).
  • Simplified and intuitive light emitting diode (LED) user interface for immediate status indication.
  • Pre-engineered pipe networks for hassle-free and expedient design and installation.
  • Two configuration modes: Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning, or extended for enhanced user experience.
  • Modular design with in-field replaceable chamber, filter and aspirator for ease of service and maintenance.
  • Installation template, different mounting orientations (upright, inverted) and ample wiring room to save time and effort.
  • Suitable for cold storage environments with -40 °C operating temperature.
  • Bluetooth interface with mobile device App for extended configuration options and rapid diagnostics.
  • General Purpose Input (GPI) for remote Reset, Disable, External Fault.
  • Password protected access for secured detector operation, diagnostics and maintenance.
  • IP40 rating for protection against ingress of foreign bodies.
  • Onboard event log up to 2100 events for user actions and smoke trends.
  • EN54-20 Certified.
Color
White
White
Material
Plastic
Plastic
Shape
Rectangle
Rectangle
Length
80.5 mm
80.5 mm
Width
205 mm
205 mm
Height
280 mm
280 mm
SKU Code
FLX-010
FLX-020

Specification

Classification data
Standard
To BS EN 54-20.
To BS EN 54-20.
Third-party certification
ActivFire, VdS, NF, BOSEC, ANATEL, RAMATEL, FCC, RED and CCC-approved.
ActivFire, VdS, NF, BOSEC, ANATEL, RAMATEL, FCC, RED and CCC-approved.
Sensitivity class
To BS EN 54-20, Class A., To BS EN 54-20, Class B., To BS EN 54-20, Class C.
To BS EN 54-20, Class A., To BS EN 54-20, Class B., To BS EN 54-20, Class C.
Sampling pipe
-
-
Arrangement
Single-pipe.
Double-pipe.
Length (maximum)
270 m.
420 m.
Air inlet holes (maximum)
5., 15., 32.
8., 28., 56.
Coverage (minimum)
1600 m².
2000 m².
Enclosure
-
-
Material
Plastic.
Plastic.
Ingress protection (minimum)
IP 40.
IP 40.
Power supply
24 V d.c.
24 V d.c.
Controls
-
-
Display type
Light-emitting diode display (LED).
Light-emitting diode display (LED).
Functions
One alarm threshold. On board memory capable of recording 2100 events.
One alarm threshold. On board memory capable of recording 2100 events.
Display the following information
Action. Alarm. Fault.
Action. Alarm. Fault.
Relay contacts
3 no. 2 A/ 30 V d.c relays.
3 no. 2 A/ 30 V d.c relays.

Additional properties

Weight
1.7 kg.
1.7 kg.
Power consumption
400 mA.
450 mA.
Operating temperature
Ambient: -40 to +55°C.
Sampled air: -40 to +55°C.
Ambient: -40 to +55°C.
Sampled air: -40 to +55°C.
Operating humidity
10–93% RH.
10–93% RH.
SoftwareVersion
N/A - out-of-the-box.
N/A - out-of-the-box.
Sensitivity
0.05 to 6.56% obs/m.
0.05 to 6.56% obs/m.
Cable
Manufacturer's standard.
Manufacturer's standard.
Communications
USB/ Bluetooth.
USB/ Bluetooth.
Accessories
Not required., Power supply unit - VPS-220-E5., Power supply unit - VPS-215-E5., Power supply unit - VPS-250-E5., ASD Sampling Hole Clips., Refrigerated Storage Sampling Kit - VSP-860., Tamper Proof Sampling Point., Flush Mount Sampling Point., Xtralis In-Line Filter., Automatic Purging Unit - F-BO-AFE70., Xtralis Test Transformer., Smoke Pen.
Not required., Power supply unit - VPS-220-E5., Power supply unit - VPS-215-E5., Power supply unit - VPS-250-E5., ASD Sampling Hole Clips., Refrigerated Storage Sampling Kit - VSP-860., Tamper Proof Sampling Point., Flush Mount Sampling Point., Xtralis In-Line Filter., Automatic Purging Unit - F-BO-AFE70., Xtralis Test Transformer., Smoke Pen.

Sustainability data

Material
Plastic
Plastic