Metsec SFS, steel framing system,  infill wall with RCM Densglas sheathing board, British Gypsum Gyproc plasterboard.
Metsec SFS, steel framing system,  infill wall with RCM Densglas sheathing board, British Gypsum Gyproc plasterboard.
Metsec SFS, steel framing system,  infill wall with RCM Densglas sheathing board, British Gypsum Gyproc plasterboard.

Verified 19 hours ago

Metsec (voestalpine Metsec)

Verified 19 hours ago

Metsec (voestalpine Metsec)

Verified 19 hours ago

Metsec (voestalpine Metsec)
Summary
Metsec steel framing system, SFS infill wall with RCM Densglas sheathing board and British Gypsum Gyproc Fireline (2x12.5 or 15mm) lining.
-
-
Application

SFS infill wall with plasterboard lining.

-
-
Description

Metsec steel framing system, SFS infill wall with RCM Densglas sheathing board and British Gypsum Gyproc Fireline (2x12.5 or 15mm) lining.

 

Resistance to Fire

voestalpine Metsec’s fire test data for SFS infill walling is to BS EN 1364 1:2015. All test data is based on UKAS-accredited tests and UKAS-accredited scope of testing.

2x12.5mm Fireline 

Fire Performance - Non-Boundary SFS Wall: 60,90 Minutes (E)

  • Test Reference - Internal: EUI-19-B-000124-A

Fire Performance - Boundary SFS Wall: 60 Minutes (EI)

  • Test Reference - Internal: EUI-19-B-000124-A
  • Test Reference - External: EUI-19-B-000148-B

2x15.0mm Fireline 

Fire Performance - Non-Boundary SFS Wall: 60,90 Minutes (E)

  • Test Reference - Internal: EUI-19-B-000148-A

Fire Performance - Boundary SFS Wall: 60 Minutes (EI)

  • Test Reference - Internal: EUI-19-B-000148-A
  • Test Reference - External: EUI-19-B-000148-B

 

MetWALL Perform Warranty

MetWALL Perform gives architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems (SFS).

This is an important addition to voestalpine Metsec’s framing range, providing warranted, UKAS-tested wall combinations, enabling clients to select the most cost-effective performance design solutions. 

 

Metsec Decarb

voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to their product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.

 

System Codes

D1-N90-B22, D1-N100-B22, D1-N120-B22, D1-N150-B22, D1-N180-B22, D1-N200-B22, D1-N210-B22, D1-N240-B22, D1-N270-B22, D1-N300-B22, D1-N350-B22, D1-N90-B23, D1-N100-B23, D1-N120-B23, D1-N150-B23, D1-N180-B23, D1-N200-B23, D1-N210-B23, D1-N240-B23, D1-N270-B23, D1-N300-B23, D1-N350-B23

SFS – Steel Framing System

Steel frame system SFS - Infill walling:

SFS ‘steel framing system’ infill walling represents our most economical framing method. It is constructed from the floor to soffit of the primary structural frame to ‘infill’ the external wall zone.

Overview of the SFS Infill Walling System:

Metsec SFS infill walling forms a secondary structure which is fixed between the primary super structure at floor and soffit. The steel frame system is generally positioned at the slab edge allowing insulation and external finishes to be installed continuously outside the main structural frame.

Parapets and Downstands:

SFS systems can incorporate parapets and downstands, which can readily be formed with SFS using Metsec’s cantilever posts, which can be incorporated within the Metsec steel framing system. These posts can also be used to break up the span of wide openings and allow the formation of ribbon windows.

Compound Sections:

In SFS steel framing systems where it is necessary to use sections with a higher capacity, single sections can be fixed together to form compound sections. This can be done for jamb, cill and lintel sections.

Infill Wall Sections Explained:

voestalpine Metsec SFS infill solution section references are designed to be easy to read and understand at a glance. Each section type is identified by a unique reference consisting of three numerical values separated by a letter or a dash unique to the voestalpines Metsec SFS Steel Framing Systems

Studs Sections explained:

Example stud reference – 090M12-50

    • 090 – Refers to the section depth of 90mm (numbers ending in 0 are always lipped)
    • M – Refers to Metsec SFS
    • 12 – Refers to the gauge (thickness) of the section i.e. 12 is 1.2mm thick
    • 50 – Refers to the width or section flange of 50mm

-
-
Product certifications
-
-
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-
SKU Code
D1-N90-B22, D1-N100-B22, D1-N120-B22, D1-N150-B22, D1-N180-B22, D1-N200-B22, D1-N210-B22, D1-N240-B22, D1-N270-B22, D1-N300-B22, D1-N350-B22, D1-N90-B23, D1-N100-B23, D1-N120-B23, D1-N150-B23, D1-N180-B23, D1-N200-B23, D1-N210-B23, D1-N240-B23, D1-N270-B23, D1-N300-B23, D1-N350-B23
-
-

Specification

Classification data
System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineers design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Insulation
Not required., Insulation between framing.
-
-
Sheathing board
RCM Denglas - 12 mm.
-
-
Framing
Metsec SFS 90 mm stud depth.
-
-
Inner layer
British Gypsum Fire Board, 12.5 mm.
-
-
Face layer
British Gypsum Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
90/ 90 minutes (insulation/ integrity).
-
-
External face
60/ 60 minutes (insulation/ integrity).
-
-
Fire performance
60 minutes (boundary wall); 90 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
127 mm.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
A1–A3 ('Production stage')

Embodied carbon as defined in BS EN 15804

Normalized unit
-
-
-
Declared unit
2.76 (standard), 1.25 (decarb) - sfs only kg CO₂ eq/kg

Certified

-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-