NBS Source
I'm a manufacturer

Compare variants

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine

Verified 2 months ago

Metsec (voestalpine Metsec)

Verified 2 months ago

Metsec (voestalpine Metsec)

Verified 2 months ago

Metsec (voestalpine Metsec)
Summary
An economical friction-fit system to assemble frames for strong, compact and lightweight non-load‑bearing partition.
Third party certification
Length
Bespoke
-
-
Width
77 mm, 82 mm, 97 mm, 102 mm, 112 mm, 119 mm, 122 mm, 124 mm, 132 mm, 142 mm, 154 mm, 173 mm, 178 mm, 198 mm, 208 mm
-
-
Height
Bespoke
-
-

Specification

Framing
Speedline 'C' Stud, 92 mm.
-
-
Insulation
Acoustic partition roll, 25 mm.
-
-
Linings
-
-
-
Inner layers
British Gypsum Gyproc FireLine, 15 mm.
-
-
Outer layers
British Gypsum Gyproc FireLine, 15 mm.
-
-
Fasteners
Speedline Drywall Screws.
-
-
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
-
-
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
-
-

Additional properties

Fire resistance
To BS 476:1987:Part 22, 120/ 120 minutes (Integrity/ Insulation).
-
-
Partition height
-
-
-
Nominal thickness
154 mm.
-
-
Calculated weighted sound reduction index (Rw)
50 Rw dB.
-
-
Centres
600 mm., 400 mm., 300 mm.
-
-
StrengthGrade
Severe duty.
-
-
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
-
-