NBS Source
I'm a manufacturer

Compare variants

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine

Verified 3 months ago

Metsec (voestalpine Metsec)

Verified 3 months ago

Metsec (voestalpine Metsec)

Verified 3 months ago

Metsec (voestalpine Metsec)
Summary
An economical friction-fit system to assemble frames for strong, compact and lightweight non-load‑bearing partition.
-
-
Application

Sectors:

  • Residential.
  • Offices.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • RMI.
  • Student accommodation.
-
-
Description

An economical friction-fit system to assemble frames for strong, compact, lightweight non-load‑bearing partitions, Speedline Partitioning Systems are suitable for use in domestic and commercial situations.


Features and benefits:

  • Quick to erect, lightweight and clean.
  • Metal stud is dimensionally accurate and will not twist or bow.
  • Range of stud widths – 50, 70, 92 and 146 mm to meet different performance requirements.
  • Services are easy to install.
  • Acoustic insulation can easily be installed to uprate sound insulation.
  • Easy to cut to length using tin snips.
  • Frames easily fit together.
  • Door frames simply formed.
  • Range of UKAS accredited tests available for Fire (30–120 mins.) and Acoustics (37–60 dB).

Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.
-
-
Product certifications
-
-
Length
Bespoke
-
-
Width
77 mm, 82 mm, 97 mm, 102 mm, 112 mm, 119 mm, 122 mm, 124 mm, 132 mm, 142 mm, 154 mm, 173 mm, 178 mm, 198 mm, 208 mm
-
-
Height
Bespoke
-
-

Specification

Classification data
Framing
Speedline 'C' Stud, 50 mm.
-
-
Linings
-
-
-
Outer layers
British Gypsum Gyproc FireLine, 12.5 mm.
-
-
Fasteners
Speedline Drywall Screws.
-
-
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
-
-
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
-
-

Additional properties

Fire resistance
To BS 476-22:1987, 30/ 30 minutes (Integrity/ Insulation).
-
-
Partition height
-
-
-
Nominal thickness
77 mm.
-
-
Centres
600 mm., 400 mm., 300 mm.
-
-
StrengthGrade
Medium duty.
-
-
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
-
-