NBS Source
I'm a manufacturer

Compare variants

SUPALUX® - Fire Protection to Partitions
SUPALUX® - Fire Protection to Partitions

Last verified by manufacturer over a year ago

Promat UK

SUPALUX® - Partitions and External Walls - Internal Partition - 2440 x 1220 mm

Last verified by manufacturer over a year ago

Promat UK

SUPALUX® - Partitions and External Walls - Internal Partition - 2500 x 1250 mm

Summary
Fire protection to internal partitions
Fire protection to internal partitions
Application

Provide fire protection to partitions

Provide fire protection to partitions

Description

Promat SUPALUX is a non-combustible calcium silicate board reinforced with selected fibres and fillers which can be used for fire protection of internal partitions.


Fire resisting walls used for partitioning buildings and enclosing compartments will be required to provide a barrier to the passage of fire from one side or the other and must therefore be also to satisfy each of the relevant criteria (integrity, insulation and if the wall is loadbearing - the loadbearing capacity).


Features and benefits:

  • Boards can be installed before the building is watertight and are suitable for areas where the humidity is up to 85%.
  • 30–240 minutes fire resistance.
  • 30 plus years proven performance.
  • High temperature environments (up to 80°C).
  • Slim constructions.
  • Multiple applications.
  • Early installation for faster build.

Promat SUPALUX is a non-combustible calcium silicate board reinforced with selected fibres and fillers which can be used for fire protection of internal partitions.


Fire resisting walls used for partitioning buildings and enclosing compartments will be required to provide a barrier to the passage of fire from one side or the other and must therefore be also to satisfy each of the relevant criteria (integrity, insulation and if the wall is loadbearing - the loadbearing capacity).


Features and benefits:

  • Boards can be installed before the building is watertight and are suitable for areas where the humidity is up to 85%.
  • 30–240 minutes fire resistance.
  • 30 plus years proven performance.
  • High temperature environments (up to 80°C).
  • Slim constructions.
  • Multiple applications.
  • Early installation for faster build.
Product certifications
Color
White
White
Finish
Smooth
Smooth
Material
Calcium silicate
Calcium silicate
Shape
Rectangle
Rectangle
Length
2440 mm, 2500 mm
2440 mm, 2500 mm
Width
1220 mm, 1250 mm
1220 mm, 1250 mm
Height
6 mm, 9 mm, 12 mm, 15 mm, 20 mm, 25 mm
6 mm, 9 mm, 12 mm, 15 mm, 20 mm, 25 mm

Specification

Classification data
Standard
BS 476-22.
BS 476-22.
Fire rating
To BS EN:13501-1, Class A.
To BS EN:13501-1, Class A.
Thickness
6 mm., 9 mm., 12 mm., 15 mm.
20 mm., 25 mm.
Edges
Square.
Square.
Colour
Off-white.
Off-white.

Additional properties

Certification
Certifire Certificate CF 420A.
Certifire Certificate CF 420A.
Frame
Horizontal sheeting rail, top hat sections, galvanised angle., Steel stud, ceiling and floor channel., Timber studs, timber noggins.
Horizontal sheeting rail, top hat sections, galvanised angle., Steel stud, ceiling and floor channel., Timber studs, timber noggins.
Insulation thickness (minimum)
Stone wool insulation thickness.
Stone wool insulation thickness.
Fillet strips
Not required., Promat SUPALUX® fillet.
Not required., Promat SUPALUX® fillet.
Inner layer
-
-
Fasteners
M4 self tapping screws and M6 anchor bolts., M4 Wood screws and M6 steel anchors.
M4 self tapping screws and M6 anchor bolts., M4 Wood screws and M6 steel anchors.
System accessories
PROMASEAL® Intumescent Sealant.
PROMASEAL® Intumescent Sealant.
Fire protection
EI30 to EI120 minutes., E120 to E240 minutes and EI15 minutes., EI60 to EI120 minutes., EI30 to EI240 minutes.
EI30 to EI120 minutes., E120 to E240 minutes and EI15 minutes., EI60 to EI120 minutes., EI30 to EI240 minutes.
Substrate
Solid or structural wall/floor.
Solid or structural wall/floor.
Moisture
Humidity up to 85%.
Humidity up to 85%.
Board size
2440 x 1220 mm.
2500 x 1250 mm.
Type:
Concealed System Grid System., Timber Stud Partition., Steel Stud Partition., Solid Partition., Shaftwall System.
Concealed System Grid System., Timber Stud Partition., Steel Stud Partition., Solid Partition., Shaftwall System.
Surface finish
Painted., Untreated.
Painted., Untreated.