NBS Source
I'm a manufacturer

Compare variants

Kingspan Thermataper TT47 - Rigid PIR Insulation Board
Kingspan Thermataper TT47 - Rigid PIR Insulation Board
Kingspan Thermataper TT47 - Rigid PIR Insulation Board

Verified 4 months ago

Kingspan Insulation

≥120 mm thick (0.024 W/m·K)

Verified 4 months ago

Kingspan Insulation

80–119 mm thick (0.025 W/m·K)

Verified 4 months ago

Kingspan Insulation

<80 mm thick (0.027 W/m·K)

Summary
A rigid thermoset polyisocyanurate (PIR) tapered insulation board.
A rigid thermoset polyisocyanurate (PIR) tapered insulation board.
A rigid thermoset polyisocyanurate (PIR) tapered insulation board.
Application

For use beneath mechanically fixed/ fully adhered single-ply waterproofing, and partially bonded built-up felt and mastic asphalt flat roofing systems.

For use beneath mechanically fixed/ fully adhered single-ply waterproofing, and partially bonded built-up felt and mastic asphalt flat roofing systems.

For use beneath mechanically fixed/ fully adhered single-ply waterproofing, and partially bonded built-up felt and mastic asphalt flat roofing systems.

Description

A tapered version of Kingspan Thermaroof TR27, Kingspan Thermataper TT47 board is designed for use beneath mechanically fixed or fully adhered single-ply non-bituminous roofing systems.


The Kingspan Thermataper range has been specifically designed to prevent water ponding, the most common cause of failure of flat roofs.


U-value calculations for the Kingspan Thermataper range incorporate BS EN ISO 6946: 2017- Annex E (Building Components and Building Elements). Annex E outlines the calculation procedure to determine the total thermal transmittance of tapered insulation - what is termed the 'Annex E U Value'.


Kingspan Thermataper TT47 is manufactured under a management system certified to ISO 9001: 2015 (Quality Management Systems. Requirements), ISO 14001: 2015 (Environmental Management Systems. Requirements), ISO 45001: 2018 (Occupational Health and Safety Management Systems), ISO 50001: 2018 (Energy Management Systems. Requirements with guidance for use) and and ISO 37301: 2021 (Compliance Management Systems. Requirements with guidance for use).


It is also manufactured in accordance with the Harmonised Standard BS EN 13165: 2012 + A2: 2016 (Thermal insulation products for buildings- Factory made rigid polyurethane foam (PUR) products- Specification).

A tapered version of Kingspan Thermaroof TR27, Kingspan Thermataper TT47 board is designed for use beneath mechanically fixed or fully adhered single-ply non-bituminous roofing systems.


The Kingspan Thermataper range has been specifically designed to prevent water ponding, the most common cause of failure of flat roofs.


U-value calculations for the Kingspan Thermataper range incorporate BS EN ISO 6946: 2017- Annex E (Building Components and Building Elements). Annex E outlines the calculation procedure to determine the total thermal transmittance of tapered insulation - what is termed the 'Annex E U Value'.


Kingspan Thermataper TT47 is manufactured under a management system certified to ISO 9001: 2015 (Quality Management Systems. Requirements), ISO 14001: 2015 (Environmental Management Systems. Requirements), ISO 45001: 2018 (Occupational Health and Safety Management Systems), ISO 50001: 2018 (Energy Management Systems. Requirements with guidance for use) and and ISO 37301: 2021 (Compliance Management Systems. Requirements with guidance for use).


It is also manufactured in accordance with the Harmonised Standard BS EN 13165: 2012 + A2: 2016 (Thermal insulation products for buildings- Factory made rigid polyurethane foam (PUR) products- Specification).

A tapered version of Kingspan Thermaroof TR27, Kingspan Thermataper TT47 board is designed for use beneath mechanically fixed or fully adhered single-ply non-bituminous roofing systems.


The Kingspan Thermataper range has been specifically designed to prevent water ponding, the most common cause of failure of flat roofs.


U-value calculations for the Kingspan Thermataper range incorporate BS EN ISO 6946: 2017- Annex E (Building Components and Building Elements). Annex E outlines the calculation procedure to determine the total thermal transmittance of tapered insulation - what is termed the 'Annex E U Value'.


Kingspan Thermataper TT47 is manufactured under a management system certified to ISO 9001: 2015 (Quality Management Systems. Requirements), ISO 14001: 2015 (Environmental Management Systems. Requirements), ISO 45001: 2018 (Occupational Health and Safety Management Systems), ISO 50001: 2018 (Energy Management Systems. Requirements with guidance for use) and and ISO 37301: 2021 (Compliance Management Systems. Requirements with guidance for use).


It is also manufactured in accordance with the Harmonised Standard BS EN 13165: 2012 + A2: 2016 (Thermal insulation products for buildings- Factory made rigid polyurethane foam (PUR) products- Specification).

Product certifications
Digital objects
Color
Yellow
Yellow
Yellow
Finish
Smooth
Smooth
Smooth
Material
Polyisocyanurate (PIR)
Polyisocyanurate (PIR)
Polyisocyanurate (PIR)
Shape
Square
Square
Square
Length
1200 mm
1200 mm
1200 mm
Width
1200 mm
1200 mm
1200 mm

Specification

Classification data
Standard
To BS EN 13165.
To BS EN 13165.
To BS EN 13165.
Fire performance
Euroclass RtF F to BS EN 13501-1:2018.
Euroclass RtF F to BS EN 13501-1:2018.
Euroclass RtF F to BS EN 13501-1:2018.
Thermal conductivity (maximum)
0.024 W/m·K.
0.025 W/m·K.
0.027 W/m·K.
Water permeability
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Water vapour permeability
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Acoustic performance
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Compressive strength at 10% deformation
150 kPa.
150 kPa.
150 kPa.
Cross section
Tapered.
Tapered.
Tapered.
Thickness (nominal)
-
-
-
Face size (length x width)
1200 x 1200 mm.
1200 x 1200 mm.
1200 x 1200 mm.
Density
Manufacturer's standard.
Manufacturer's standard.
Manufacturer's standard.
Recycled content
0% (minimum) to BS EN ISO 14021.
0% (minimum) to BS EN ISO 14021.
0% (minimum) to BS EN ISO 14021.
Facing
Autohesively bonded coated glass tissue.
Autohesively bonded coated glass tissue.
Autohesively bonded coated glass tissue.
Edges
Square.
Square.
Square.

Additional properties

Standard Falls
1:30., 1:40., 1:60., 1:80.
1:30., 1:40., 1:60., 1:80.
1:30., 1:40., 1:60., 1:80.

Sustainability data

Country of product manufacture
United Kingdom
United Kingdom
United Kingdom
Manufacturing plant location
Pembridge, Leominster HR6 9LA, UK
Pembridge, Leominster HR6 9LA, UK
Pembridge, Leominster HR6 9LA, UK
Material
Polyisocyanurate (PIR)
Polyisocyanurate (PIR)
Polyisocyanurate (PIR)
Carbon dioxide equivalent
Normalized unit
(kg CO₂ eq/kg)
A1–A3 ('Production stage') :
-
A1–A3 ('Production stage') :
-
A1–A3 ('Production stage') :
-
Declared unit

Certified

A1–A3 ('Production stage') :
7.15

Certified

A1–A3 ('Production stage') :
7.15

Certified

A1–A3 ('Production stage') :
7.15
Recycled content
0 %
0 %
0 %