Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)

Last verified by manufacturer over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
-
-
Description

Metsec SFS infill walling forms a secondary structure which is fixed between the primary super structure at floor and soffit. It is generally positioned at the slab edge allowing insulation and external finishes to be installed continuously outside the main structural frame.


Features and benefits:

  • Quicker and easier to install than conventional deflection brackets.
  • Simpler and faster to install than traditional masonry infill.
  • Fewer components on site – less components to store, lose or work with.
  • Fix and forget system – no concerns about missing brackets.
  • Visible centre line indent indicates fixing location.
  • Vertical slots at 25 mm centres allow for flexibility of stud positions.


Variants:

  • Code 1: 90mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N90-B22.
  • Code 2: 120mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N120-B2.
  • Code 3: 150mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N150-B22.
  • Code 4: 180mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N180-B22.
  • Code 5: 210mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N210-B22.
  • Code 6: 240mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N240-B22.
  • Code 7: 270mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N270-B22.
  • Code 8: 300mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N300-B22.
  • Code 9: 350mm stud, Fire in/out 90min Out/in 30min 2 x 12.5mm Fire Board V1-N350-B22.
  • Code 10: 90mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-V1-N90-B22.
  • Code 11: 120 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-V1-N120-B22.
  • Code 12: 150 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N150-B22.
  • Code 13: 180 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N180-B22.
  • Code 14: 210 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N210-B22.
  • Code 15: 240 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N240-B22.
  • Code 16: 270mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N270-B22.
  • Code 17: 300 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N300-B22.
  • Code 18: 350 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Rockwool Duoslab DXXX-Y1-N350-B22.
  • Code 19: 90 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N90-B22.
  • Code 20: 120mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N120-B22.
  • Code 21: 150mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N150-B22.
  • Code 22: 180mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N180-B22.
  • Code 23: 210mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N210-B22.
  • Code 24: 240mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N240-B22.
  • Code 25: 270mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N270-B22.
  • Code 26: 300 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N300-B22.
  • Code 27: 350 mm stud, Fire in/out 90min Out/in 60min 2 x 12.5mm Fire Board Ins Kingspan K15 KXXX-V1-N350-B22.
  • Code 28: 90mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N90-B23.
  • Code 29: 120 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N120-B23.
  • Code 30: 150 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N150-B23.
  • Code 31: 180 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N180-B23.
  • Code 32: 210 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N210-B23.
  • Code 33: 240 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N240-B23.
  • Code 34: 270mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N270-B23.
  • Code 35: 300 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N300-B23.
  • Code 36: 350mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board V1-N350-B23.
  • Code 37: 90 mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N90-B23.
  • Code 38: 120mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N120-B23.
  • Code 39: 150mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N150-B23.
  • Code 40: 180 mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N180-B23.
  • Code 41: 210mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N210-B23.
  • Code 42: 240 mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N240-B23.
  • Code 43: 270mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N270-B23.
  • Code 44: 300mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N300-B23.
  • Code 45: 350 mm stud, Fire in/out 120min Out/in 90min 2 x 15mm Fire Board Ins Rockwool Duoslab DXXX-V1-N350-B23.
  • Code 46: 90mm stud,Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N90-B23.
  • Code 47: 120 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N120-B23.
  • Code 48: 150 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N150-B23.
  • Code 49: 180 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N180-B23.
  • Code 50: 210mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N210-B23.
  • Code 51: 240mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N240-B23.
  • Code 52: 270 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N270-B23.
  • Code 53: 300 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N300-B23.
  • Code 54: 350 mm stud, Fire in/out 120min Out/in 60min 2 x 15mm Fire Board Ins Kingspan K15 KXXX-V1-N350-B23.


-
-
Product certifications
-
-

Specification

Classification data
Framing members
Metsec SFS, 90 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Sheathing board
Euroform Versaliner - 12 mm.
-
-
Inner layers
British Gypsum Fire Board, 12.5 mm.
-
-
Face layer
British Gypsum Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
30/30 minutes (Insulation/ Integrity).
-
-
Internal face
90/ 90 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-
Product Reference
V1-N90-B22
-
-

Sustainability data

Carbon dioxide equivalent
Normalized unit
(kg CO₂ eq/kg)
A1–A3 ('Production stage') :
2.76
A1–A3 ('Production stage') :
-
A1–A3 ('Production stage') :
-
Declared unit

Self-declared

A1–A3 ('Production stage') :
2.76

Self-declared

A1–A3 ('Production stage') :
-

Self-declared

A1–A3 ('Production stage') :
-
Recyclability
94%
-
-
Recycled content
60 %
-
-