Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining
Metsec SFS Infill Wall with Versaliner Sheathing Board and British Gypsum Lining

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)

Verified over a year ago

Metsec (voestalpine Metsec)
Summary
Floor to soffit ‘infill’ system to the external wall zone.
Third party certification

Specification

Framing members
Metsec SFS, 90 mm.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By Structural Engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Sheathing board
Euroform Versaliner - 12 mm.
-
-
Inner layers
British Gypsum Fire Board, 12.5 mm.
-
-
Face layer
British Gypsum Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap/ Partition Brace.
-
-
External face
30/30 minutes (Insulation/ Integrity).
-
-
Internal face
90/ 90 minutes (Insulation/ Integrity).
-
-
Thermal
Variable.
-
-
Air tightness
Variable.
-
-
Wind load
To BS EN 1991-4, plus self weight.
-
-
Product Reference
V1-N90-B22
-
-

Sustainability data

Embodied carbon
2.76 kg CO₂ eq/kg
-
-
Recyclability
94%
-
-
Recycled content
60 %
-
-