Summary
Bonded internal wall insulation; bulking insulation between rafters, studs and joist, external insulation behind rain screen cladding (with UDB membrane).
Color
Brown
-
-
Material
Woof fibre insulation
-
-
Shape
Rectangle
-
-
Size
1350 x 600 mm
-
-

Specification

General requirements
Insulation products generally.
-
-
Standard
To BS EN 13171.
-
-
Thickness
40 mm.
-
-
Density
110 kg/m³.
-
-
Edges
Square.
-
-
Thermal conductivity (maximum)
0.037 W/(m*K).
-
-
Fire performance
Class E to EN 13501-1.
-
-

Additional properties

Product Reference
Steico Therm – Dry
-
-
SpecificHeatCapacity
2100 J/(kg *K).
-
-
Compressive Strength (at 10% deformation)
0.05 N/mm².
-
-
Compression strength
50 kPa.
-
-
TensileStrength
5 kPa.
-
-
Water absorption
≤ 1.0 kg/m².
-
-
Thermal resistance
1.05 (m² *K)/W.
-
-
Weight