Tested and compliant to BS 476-22, BS EN 1634-1:2008, BS EN 1634-3:2014.
Tested and compliant to BS 476-22, BS EN 1634-1:2008, BS EN 1634-3:2014.
Tested and compliant to BS 476-22, BS EN 1634-1:2008, BS EN 1634-3:2014.
Configuration
Double leaf, single action., Leaf and part leaf, single action., Bespoke.
Double leaf, single action., Leaf and part leaf, single action., Bespoke.
Double leaf, single action., Leaf and part leaf, single action., Bespoke.
Doorset size
1780 x 2100 mm.
1780 x 2100 mm.
1780 x 2100 mm.
Performance
-
-
-
Fire resistance
-
-
-
Integrity
To BS EN 1634-1: 2014, 120 minutes.
To BS EN 1634-1: 2014, 60 minutes.
To BS EN 1634-1: 2014, 240 minutes.
Reaction to fire
120 minutes.
60 minutes.
240 minutes.
Acoustic performance
28 dB., 35 dB., 45 dB., 50 dB.
28 dB., 35 dB., 45 dB., 50 dB.
28 dB., 35 dB., 45 dB., 50 dB.
Thermal
1.8 W/m²K.
1.8 W/m²K.
1.8 W/m²K.
Intruder resistance
-
-
-
Minimum requirement
Modular mortice lock/ additional flush bolt to inactive leaf.
Modular mortice lock/ additional flush bolt to inactive leaf.
Modular mortice lock/ additional flush bolt to inactive leaf.
Frame
-
-
-
Material
1.5 mm folded Magnelis steel with fixed reveal, type A., 1.5 mm folded Magnelis steel with fixed reveal, type B., 1.5 mm folded Magnelis steel with fixed reveal, type C., 1.5 mm folded Magnelis steel with fixed reveal, type D.
1.5 mm folded Magnelis steel with fixed reveal, type A., 1.5 mm folded Magnelis steel with fixed reveal, type B., 1.5 mm folded Magnelis steel with fixed reveal, type C., 1.5 mm folded Magnelis steel with fixed reveal, type D.
1.5 mm folded Magnelis steel with fixed reveal, type A., 1.5 mm folded Magnelis steel with fixed reveal, type B., 1.5 mm folded Magnelis steel with fixed reveal, type C., 1.5 mm folded Magnelis steel with fixed reveal, type D.
Threshold
15 mm stepped threshold for compliance to the Equality Act 2010.
15 mm stepped threshold for compliance to the Equality Act 2010.
15 mm stepped threshold for compliance to the Equality Act 2010.
Perimeter seals or inserts
Variable sub frame to allow up to 30 mm tolerance for site installations.
Variable sub frame to allow up to 30 mm tolerance for site installations.
Variable sub frame to allow up to 30 mm tolerance for site installations.