Steel Substrate (C1–C4)

International Coatings

Cellulosic Passive Fire Protection (PFP) system for internal non-decorative steelwork.

Jump to:
+61 3 9313 4501 Website

Application

Suitable for non-decorative internal steelwork in low corrosive (C1–C2) to highly corrosive environments (C3–C4).


Coats by environmental classification:

Up to C4

  • 1st coat: Interguard 251HS. DFT: 75 microns.
  • 2nd coat: Interchar 1260. DFT: To be determined by steel section and fire duration. Must be confirmed with manufacturer prior to application.

Description

Interchar® 1260 is a thin film, waterborne intumescent coating system suitable for cellulosic fire protection up to 90 minutes.

General information

Color

White

Finish

Matt

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

-

Manufacturer guidance

Refer to International Protective Coatings for further details relating to performance warranty.

Uniclass

Ss_40_90_60_85 Special coating systemsPrimary

SpeedSpec

09910 Painting

SpecPack

09910 Painting

NATSPEC National Classification System

0671 Painting

Specification data - Special coating systems

Preparation

All surfaces to be prepared in accordance with the coating manufacturer's written instructions.

Primer coats

Interguard 251HS. DFT: 75 microns.

Finishing coats

Interchar 1260.

Manufacturer guidance

Dry film thickness (DFT) of Interchar 1260 is determined by steel section and fire duration. Final DFT must be confirmed by manufacturer prior to application.

Execution

Applied in accordance with the coating manufacturer's written instructions.

Surface material

Steel surfaces should be assessed and treated in accordance with ISO 8504:2000, followed by abrasive blast cleaning to achieve Sa2½ in accordance with ISO 8501-1:2007. Refer to International Protective Coatings for full surface preparation requirements prior to commencement of work.

Application temperature

>10°C.

Durability

Medium (7–15 years).

High (15-25 years).

Manufacturer guidance

Refers to system durability per ISO 12944.1:2017.

Fire resistance

Up to 90 minutes (1.5 hours).

Colour

White.

Finish

Matt.

Volatile organic compound (VOC)

23 g/L.

Manufacturer guidance

Refers to values for Interchar 1260 only, EPA Method 24.

Sustainability data

Contains Red List materials

Yes

Country of material origin

Australia

Country of product manufacture

Australia

Literature

Interchar® 1260

Interchar® 1260

Interchar® 1260 Application Guidelines

Interchar® 1260 Application Guidelines

Interchar® 1260 Brochure

Interchar® 1260 Brochure

Fire Protection for Structural Steel

Fire Protection for Structural Steel

Proof of Performance (Bridges)

Proof of Performance (Bridges)

Proof of Performance (Infrastructure)

Proof of Performance (Infrastructure)

Proof of Performance (Stadia)

Proof of Performance (Stadia)