NBS Source
I'm a manufacturer

Application

Small to Mid-sized projects.

Description

The CW150 Curtain Wall has been developed to provide a robust and flexible Curtain Wall solution for small to mid-sized curtain wall projects. While targeted at buildings up to a nominal 10 stories high, due to its superior design it may be used on larger projects depending upon wind loads. Key features of the CW150 is the strict AS4284 testing regime and the co-development of building and mullion brackets allowing the CW150 to be installed as a fully tested system without having to independently engineer brackets for each project. Another key feature is the integration of sun shading directly into the Curtain Wall system without sacrificing structural or water performance. Proprietary brackets have been designed to allow the fitment of vertical or horizontal sunshade directly on the mullions (not compatible with structural mullions).

Being based upon the AGS 629 Flushline 150mm, it also offers compatibility with a broad range of operable products in the AGS family.

General information

Finish

Powder-coated

Material

Aluminium

Shape

Rectangle

Width

1500 mm

Height

3500 mm

Uniclass

Ss_25_10_20_90 Unitized curtain walling systemsPrimary

NATSPEC National Classification System

0432 Curtain Walls

SpecPack

08900 Glazed Curtain Walls

SpeedSpec

08520 Metal Windows and Glazed Doors

Specification data - Unitized curtain walling systems

Frame dimensions

150mm x 75mm.

Manufacturer guidance

For detailed mullion information please contact Capral Spec Team. This system is limited to a Panel Height of 3.5 m, Panel Width of 1.5 m and weight of 210kgs.

Glazing

Single.

Double.

Performance:

Max SLS: 3000pa / ULS=4500pa / WATER: 900pa Static & 1800pa Cyclic.

Standards

AS4284.

Cyclonic impact testing

No

Bushfire attack level (BAL)

up to BAL29 DTS.

Integral accessories

• Silicon Jointed External Face.
• Mullion brackets for external shading.

Sustainability data

Country of material origin

Australia

Country of product manufacture

Australia

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

8 kg·CO₂e/kg

Recyclability

100% recyclable.

Literature

AGS CW150 Technical Data Manual 2006

AGS CW150 Technical Data Manual 2006

Similar products from Capral Aluminium

CW116 Curtain wall

CW116 Curtain wall

CW175 Curtain wall