Verifierad av tillverkaren för 3 månader sedan
Our most advanced range - Xtrafire lintels are single cast concrete lintels cast in an ex-steel mould. Available in fire ratings of 60, 90, 120, 180, and 240 minutes with a smooth finish.
For use in walls and partitions that require enhanced fire resistance. Suitable for use in hospitals, schools, nursing homes, sheltered and student accommodation, flats, offices, industrial developments, sports stadia.
Typical Application and Uses:
Naylor XtraFire™ lintels are suitable for use in the construction of a wide range of applications including:
Naylor XtraFire™ concrete lintels are single cast lintels which have been independently tested for fire resistance by Warrington Fire and for loading by Lucideon.
Pre-stressed innovative lintels ensuring optimum performance with enhanced fire resistance.
Lintels are 100 mm-wide pre-stressed concrete lintels with a R60, 90, 120, 180 and 240-minute fire rating. Xtrafire lintels are a single cast product with no additional coating and can easily be fixed into on site. They are more durable and have greener credentials than other lintels.
Features and benefits:
XtraFire™ lintels are fire rated up to R240 minutes for load-bearing and are available in five sections in widths of 100mm, 140mm and 215mm.
XtraFire™ lintels have an ex steel mould finish similar to our current fairfaced product made from specialist wet cast concrete. Having pencil round edges but with a possibility of small air holes on the lintel surface.
Additional benefits of XtraFire™ lintels:
Product Certification
Färg | Grey |
ytbehandling | Smooth |
Material | Concrete |
Form | Rectangle |
Längd | 600 mm 750 mm 900 mm 1050 mm 1200 mm |
Bredd | 100 mm |
Höjd | 215 mm |
Garantibeskrivning | 50 year Vägledning för specifikationsalternativ: Design life. |
Uniclass | |
CAWS | F30/745 Prestressed concrete lintels |
Product range |
Klassificeringsdata | |
Standard | To BS EN 845-2. |
Types | Single. |
Dimensions | |
Length | 600 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 750 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 900 mm. Vägledning för specifikationsalternativ: Clear span: 700 mm. Unfactored load: 65.73 kN/m. 1050 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 1200 mm. Vägledning för specifikationsalternativ: Clear span: 1000 mm. Unfactored load: 47.67 kN/m. 1350 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 1500 mm. Vägledning för specifikationsalternativ: Clear span: 1200 mm. Unfactored load: 39.41 kN/m. 1650 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 1800 mm. Vägledning för specifikationsalternativ: Clear span: 1500 mm. Unfactored load: 25.10 kN/m. 1950 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 2100 mm. Vägledning för specifikationsalternativ: Clear span: 1800 mm. Unfactored load: 19.40 kN/m. 2250 mm. 2400 mm. Vägledning för specifikationsalternativ: Clear span: 2100 mm. Unfactored load: 14.40 kN/m. 2550 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 2700 mm. Vägledning för specifikationsalternativ: Clear span: 2400 mm. Unfactored load: 11.07 kN/m. 2850 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 3000 mm. Vägledning för specifikationsalternativ: Clear span: 2700 mm. Unfactored load: 8.74 kN/m. 3150 mm. 3300 mm. Vägledning för specifikationsalternativ: Clear span: 3000 mm. Unfactored load: 7.05 kN/m. 3450 mm. Vägledning för specifikationsalternativ: Consult manufacturer for further details. 3600 mm. Vägledning för specifikationsalternativ: Clear span: 3200 mm. Unfactored load: 6.17 kN/m. |
Cross section | 100 x 215 mm. |
Characteristics | |
Deflection under load | 3.5 mm. Vägledning för specifikationsalternativ: Deflection at 1/3 of load capacity. |
Freeze-thaw | Resistant. |
Mass | 49 kg/m. |
Resistance to fire | R60 (60 minutes). R90 (90 minutes). R120 (120 minutes). R180 (180 minutes). R240 (240 minutes). |
Thermal conductivity | 1.52 W/m·K. Vägledning för specifikationsalternativ: Thermal conductivity λ 10,dry, mat, to EN 1745. |
Innehåller Red List-material | No |
Materialets ursprungsland | United Kingdom |
Produktens tillverkningsland | United Kingdom |
Material | Concrete |
| Carbon dioxide equivalent | |
Koldioxidekvivalent, enligt definition i BS EN 15804 Självdeklarerad | |
Steg Normaliserad enhet (kg CO₂ eq/kg) Deklarerad enhet (kg CO₂ eq/kg) Steg:A1–A3 (”Produktionsskede”) Normaliserad enhet :0.19 (kg CO₂ eq/kg) Deklarerad enhet :0.19 Värdevägledning: A1-A3Raw materials are locally and responsibly sourced. | |
Återvinningsbarhet | Vägledning för specifikationsalternativ: Some raw materials are recycled. |
Detta BIM-objekt har skapats för att uppfylla kraven i
Läs mer om
| Plattform | Kompatibel | Version |
|---|---|---|
| - | 1 | |
| - | 1 |
Faced Fire R11 [60 minutes] - Lintels
Faced Fire R13 [60 minutes] - Lintels
Faced Fire R14 [60 minutes] - Lintels
Faced Fire R190 [60 minutes] - Lintels
Faced Fire R2 [60 minutes] - Lintels
Faced Fire R3 [60 minutes] - Lintels
Faced Fire R7 [60 minutes] - Lintels
Faced Fire R8 [60 minutes] - Lintels
Faced Fire S5 [60 minutes] - Lintels
Faced Fire S8 [60 minutes] - Lintels