Verifierad av tillverkaren för 1 månad sedan
KIWA BDA
Certifikattyp
EPD
Certifikattyp
External wall insulation (EWI) system incorporating a range of components including A1 non-combustible stone wool insulation and a clay brick slip finish.
Suitable for a range of projects where substrates require a drainage cavity, including retrofit, remediation, high-rise buildings, and new build.
External wall insulation system for steel frame substrates, incorporating an A1 non-combustible stone wool insulation board, this system achieves a system fire classification of A1 to BS EN 13501-1, allowing it to be used on a building of any height.
Providing a familiar brick finish with clay brick slips, it provides a cost-effective solution. The Wetherby RagRail helps to simplify the installation of this system and provide a partially ventilated cavity.
Features and benefits:
Färg | White Grey Red Yellow Orange |
ytbehandling | Brick |
Material | Clay Mineral wool Stone wool Aluminium Steel |
Form | Other |
Längd | Bespoke |
Bredd | Bespoke |
Höjd | Bespoke |
Garantibeskrivning | Ten year 25 year |
Uniclass | |
CAWS | M21/20 Rendered external wall insulation systems M21/210 Rendered external wall insulation systems |
Klassificeringsdata | |
System performance | Durability - 30 years; fire performance to EN 13501-1, Class A1. |
Support rails and brackets | |
Fixing method | |
Material | Wetherby aluminium base rail with treated timber battens. Vägledning för specifikationsalternativ: 2.5 m long aluminium base rail for fixing to the sheathing board. Treated timber battens (minimum dry strength grade C16 in accordance with BS EN 14081-1:2016). Wetherby aluminium base rail with RagRail steel spacer rails. Vägledning för specifikationsalternativ: 2.5 m long aluminium base rail for fixing to the sheathing board. Epsitec spacer rail, galvanized steel top-hat rail sections. |
Bracket fixings | Ejot LS range. Vägledning för specifikationsalternativ: Case hardened, carbon steel, self-drilling screws. |
Boards | |
Material | To BS EN 12467, fibre cement board. To BS EN 12467, cement particle board (CPB). To BS EN 313-1, plywood. To BS EN 300, oriented strand board (OSB). |
Fixings | Ejot JT2-D6 range. Vägledning för specifikationsalternativ: Case hardened steel fastener. Ejot JT3-D6-H range. Vägledning för specifikationsalternativ: Stainless steel bi-met high thread fastener. Other. Vägledning för specifikationsalternativ: Other fixings may be used provided they can be demonstrated to have equal or higher pull-out, plate diameter and plate stiffness characteristics. Consult manufacturer for details. |
Insulation | |
Material | Wetherby stone wool insulation. Vägledning för specifikationsalternativ: Rockwool External Wall Dual Density Slab. Thermal performance ranging from 0.030 Wm²/K. Thicknesses between 80–250 mm (in 10 mm increments).
|
Additional mechanical fixings | Ejot TKR range. Vägledning för specifikationsalternativ: Self-drilling. Case hardened countersunk carbon steel fastener. Ejot TKE range. Vägledning för specifikationsalternativ: Stainless steel tapping screws with stainless steel washers. KC insulation washers. Vägledning för specifikationsalternativ: Insulation washer with integral cap suitable for attachment of insulation layers to wooden and sheet metal substrates. Other. Vägledning för specifikationsalternativ: Other fixings may be used provided they can be demonstrated to have equal or higher pull-out, plate diameter and plate stiffness characteristics. Consult manufacturer for details. |
Fire barriers and stops | |
Material | Tenmat FF 102/50 Intumescent Strip. Tenmat NVFB Non-Ventilated Fire Barrier. |
Beads and trims | Render beads. Tillverkarens vägledningConsult manufacturer and insert requirements. |
Movement joints | |
Form with | Render beads. Vägledning för specifikationsalternativ: Consult manufacturer and insert requirements. |
Sealant | Arbosil LMS. Vägledning för specifikationsalternativ: Arbosil LMS is a one-part neutral cure silicon sealant which cures on exposure to moisture vapour to form an elastic silicone rubber. Available in a range of colours; consult manufacturer's literature for more details. Nullifire FS703. Vägledning för specifikationsalternativ: FS703 is a low modulus, neutral cure, silicone sealant, suitable for linear gaps sealing in order to reinstate the fire performance in compartment walls and floors. Available in white as standard and black and grey upon request (may be subject to minimum order quantities). Consult manufacturer's literature for more details. |
Render carrier or reinforcement | |
Material | Alkali resistant reinforcing scrim cloth (R 131 A101). Vägledning för specifikationsalternativ: Alkali-resistant glass fibre mesh. Nominal weight of 160 g/m². |
Mesh size | 3.5 x 3.8 mm. Vägledning för specifikationsalternativ: Supplied in 50 x 1 m rolls and available in 1.1 and 0.5 mm thickness. Insert requirements. |
Fixings | Ejot TKR range. Vägledning för specifikationsalternativ: Self-drilling. Case hardened countersunk carbon steel fastener. Ejot TKE range. Vägledning för specifikationsalternativ: Stainless steel tapping screws with stainless steel washers. Other. Vägledning för specifikationsalternativ: Other fixings may be used provided they can be demonstrated to have equal or higher pull-out, plate diameter and plate stiffness characteristics. Consult manufacturer for details. |
Render | |
Application | Finish coat. |
Decorative finish | Wetherby brick slip adhesive with Wetherby brick slips. Vägledning för specifikationsalternativ:
|
Colour | Tillverkarens vägledningAvailable in a wide range of colours; consult manufacturer for more details and insert requirements. |
System accessories | Tillverkarens vägledningConsult manufacturer for details and insert requirements. |
Mortar | Wetherby pointing mortar. Vägledning för specifikationsalternativ: Polymer modified sand/ cement based pointing mortar (class M5). Available in a range of colours, consult manufacturer and insert requirements. |
Scrim adhesive | Wetherby scrim adhesive. Vägledning för specifikationsalternativ: Cement-based, polymer modified basecoat. |
Impact resistance | Category I. |
NBS LCA hjälper byggproffs att mäta miljöpåverkan och identifiera produkter med låga koldioxidutsläpp för mer hållbara projekt.

Innehåller Red List-material | No |
Materialets ursprungsland | Europe |
Produktens tillverkningsland | Europe |
Tillverkningsanläggningens plats | |
Material | Clay Mineral wool Stone wool Aluminium Steel Fibre cement Plywood Oriented strand board (OSB) Fiber-glass Fibre-reinforced Mineral board Mineral fibre Rock fibre Rock fibre mineral wool Rock mineral fibre Rock mineral wool Stonewool Brick |
Förväntat liv | 30 year |
Detta BIM-objekt har skapats för att uppfylla kraven i
Läs mer om
| Plattform | Kompatibel | Version |
|---|---|---|
| - | 1 | |
| - | 1 |
Masonry Stone Wool Acrylic Brick Slip A2 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Masonry Stone Wool Brick Effect Render A1 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Masonry Stone Wool Clay Brick Slip A1 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Masonry Stone Wool Dash Render A1 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Masonry Stone Wool Mineral Render A1 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Masonry Stone Wool Silicone Render A2 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Soqel - A2 Rated Below DPC External Wall Insulation System - External Wall Insulation System
Steel Frame Cavity Rail Stone Wool Acrylic Brick Slip A2 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Steel Frame Cavity Rail Stone Wool Silicone Render A2 Rated External Wall Insulation (EWI) System - External Wall Insulation System
Steel Frame Direct Fix Stone Wool Acrylic Brick Slip A2 Rated External Wall Insulation (EWI) System - External Wall Insulation System