Insulated fire protection system for protection of shafts and voids in multi-storey buildings with a rapid installation system preventing continuous routes for the spread of fire.

Hoppa till:
+44 (0)1275 377773 Webbplats

Applikation

Protection of shafts and voids in multi-storey buildings with a rapid installation system preventing continuous routes for the spread of fire.

Beskrivning

EI60 Shaftwall System with 25 mm glass mineral wool insulation, classified to EN 13501-2:2016.


Allmän information

Färg

Pink

ytbehandling

Smooth

Material

Plasterboard

Steel

Gypsum

Glass mineral wool

Bredd

Bespoke

Höjd

Bespoke

Garanti­beskrivning

Lifetime

Vägledning för specifikationsalternativ:

Etex Building Performance Limited offers both a comprehensive Lifetime System Warranty (excl. Aquaboard™ and Weather Defence) and External Board Warranty (Incl. Aquaboard™ - 10 Years and Weather Defence - 12 Years). For full details see the full Warranty and Proprietary Systems Policy at www.siniat.co.uk/knowledge-centre/. Etex Building Performance Limited warrants to the purchaser that the Siniat drywall systems as originally designed, built and unaltered will perform to the original laboratory performance parameters as set out in the Siniat Drywall Manual and other relevant literature as published by Siniat. The System must be constructed solely with the proprietary products and components as supplied by Siniat. The System must be installed by a professional installer in accordance with the Siniat Drywall Manual, the specification documents issued by Siniat, CAD drawings, advice and all relevant and applicable construction standards and regulations.

Uniclass

Ss_25_10_30_35 GipsskivavdelningssystemPrimär

CAWS

K10/125 Metal stud partition system

K10/30 Metal stud

Product range

Shaftwall / Siniat Shaftwall

Specifikationsdata - Gipsskivavdelningssystem

Systemprestanda

Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

49 Rw (dB).

Fire resistance to BS EN 1364-1 and classification to BS EN 13501-2

EI 60.

Duty rating to BS 5234-2

Severe duty (SD).

Maximum height - cold state

6700 mm.

Maximum height - fire state

4000 mm.

Thickness

171 mm.

Klassificeringsdata

System performance

All Siniat systems should be constructed to BS 8000-8:2023 'The Standard for Workmanship on construction sites - Design and installation of dry lining systems. Code of practice.'

System manufacturer

Siniat.

Framing

146 mm Siniat CH Studs CHS19146/B at 600 mm centres.
146 mm Siniat E Studs ES19146/B.
Head track: 148 mm Siniat U Track Deep Flange UDT148/P.
Base track: 148mm Siniat J Track JT148/B.

Tillverkarens vägledning

All Siniat CH-Studs and E-Studs to be a minimum 25 mm shorter than floor to ceiling height or by deflection amount, whichever is greater. 

Insulation

Glass mineral wool.

Vägledning för specifikationsalternativ:

  • 25 mm thick.

Linings

Face A Plasterboard Linings - Inner Layer: 19 mm Siniat Fire Core Board.
Face B Plasterboard Linings - Inner Layer: 12.5 mm Siniat Fire Board.
Face B Plasterboard Linings - Outer Layer: 12.5 mm Siniat Fire Board.

Tillverkarens vägledning

Shaft side lining: 19 mm Siniat Fire Core Board.

Corridor/room side lining: 12.5 mm Siniat Fire Board.

Fasteners

Face B Inner Layer Fixing: 25 mm Siniat Self Tapping Screws at 600 mm centres.
Outer Layer Fixing: 38 mm Siniat Self Tapping Screws at 300 mm centres.

Joint treatment

Decorative.

Vägledning för specifikationsalternativ:

Outer layer room side boards to be taped and jointed using appropriate Siniat compounds and tape.

Non-decorative.

Vägledning för specifikationsalternativ:

Outer layer room side boards to be taped and jointed using appropriate Siniat compounds and tape to at least first stage (bedding).

Finish

Decorative.
Non-decorative.

System accessories

Siniat Flat Strap FS50/Rx.

Vägledning för specifikationsalternativ:

For use where partition height exceeds board height; to be fixed behind all horizontal joints to provide substrate for board fixing.

Sealing (joints and penetrations)

Siniat Intumescent Acoustic Sealant.

Vägledning för specifikationsalternativ:

Apply continuous beads of Siniat Intumescent Acoustic Sealant around the perimeter of the framing or to the edge of outer layers of board, ensuring that all air-paths are sealed. 


All penetrations should use supporting constructions detailed in the Siniat Drywall Manual unless superseded by specific test information. For combined, warrantied performance specify FSi fire-stopping products. For cPVC pipe sealing, use FSi PYROPRO® HPE Sealant in place of Siniat Intumescent Acoustic Sealant.

Standards

All products are CE marked and UKCA marked in accordance with Construction Products Regulation where relevant standards or European Technical Approvals exist. All boards to conform to BS EN 520 or alternative standard where appropriate. Metal framing components are hot-dipped galvanized steel to BS EN 10346. Metal sections rolled to BS EN 10162. Metal studs, tracks and accessories conform to BS EN 14195 where required. Drywall screws conform to BS EN 14566.

Sealer coat

Siniat Drywall Sealer.

Cavity size

126 mm.

System code

CH14B-19FC#212F-25G

Hållbarhetsdata

Tydlighet för koldioxidsnål design

NBS LCA hjälper byggproffs att mäta miljöpåverkan och identifiera produkter med låga koldioxidutsläpp för mer hållbara projekt.

Utforska NBS LCA
LCA illustration

Materialets ursprungsland

Spain

Vägledning för specifikationsalternativ:

Applies to the bulk material (gypsum) only. Other components are from other countries. Consult manufacturer for details.

Produktens tillverkningsland

United Kingdom

Tillverkarens vägledning

UK applies to the majority of manufacture but a small percentage of finished items are imported. Contact manufacturer for details.

Material

Plasterboard
Steel
Gypsum
Glass mineral wool
Carbon dioxide equivalent

Koldioxidekvivalent, enligt definition i BS EN 15804

Certifierad

Steg
Normaliserad enhet (kg CO₂ eq/kg)
Deklarerad enhet (kg CO₂ eq/unit)
Steg:A1–A3 (”Produktionsskede”)
Normaliserad enhet :
Deklarerad enhet :-

Tillverkarens vägledning

Latest EPD information available from: https://www.siniat.co.uk/en-gb/documentation/

Återvinningsbarhet

Gypsum and metal components can be recycled depending on the segregation of all materials.

Återvunnet innehåll

-

Tillverkarens vägledning

Gypsum average 33.5% and metal average 17%.

Produktcertifieringar

BIM-objekt

PlattformKompatibelVersion
Revit
-

2

Produktcertifieringar

EN 13501-2

EN 13501-2

Fire classification report EUI-24-000196

CCPI System

CCPI System

CCPI accreditation for Siniat Shaftwall systems

EPD

EPD

EPD - Siniat Fire Board

Dokumentation

Siniat Drywall Manual - Shaftwall

Siniat Drywall Manual - Shaftwall

Liknande produkter från Siniat

Siniat A1 Shaftwall System – CH14B-19WD#312WD

Siniat A1 Shaftwall System – CH14B-19WD#312WD

Siniat A1 Shaftwall System – CH90B-19WD#312WD

Siniat A1 Shaftwall System – CH90B-19WD#312WD

Siniat EI120 Shaftwall System – CH14B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH14B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH60B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH60B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH90B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH90B-19FC#315F-25G

Siniat EI60 Shaftwall System - CH60B-19FC#212F

Siniat EI60 Shaftwall System - CH60B-19FC#212F

Siniat EI60 Shaftwall System – CH14B-19FC#212F

Siniat EI60 Shaftwall System – CH14B-19FC#212F

Siniat EI60 Shaftwall System – CH60B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH60B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH90B-19FC#212F

Siniat EI60 Shaftwall System – CH90B-19FC#212F

Siniat EI60 Shaftwall System – CH90B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH90B-19FC#212F-25G