NBS Source
Jag är en tillverkare
Jämför varianter

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud

Verifierad av tillverkaren för 6 månader sedan

K10 127 2 x 12.5 mm Fire Board

Protektor Group UK Variant:

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Hoppa till:
01562 515200 Webbplats

Applikation

  • Suitable for use where fire and acoustic performance is required.
  • Suitable for use in large commercial spaces.

Beskrivning

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Features and benefits:

  • Severe duty rating to BS 5234.
  • Sound insulation (Rw dB): up to 53 dB Rw.
  • Available with or without acoustic partition roll.

Allmän information

Färg

Other

ytbehandling

Other

Material

Plasterboard

Metal

Form

Other

Längd

Bespoke

Bredd

Bespoke

Höjd

Bespoke

Uniclass

Ss_25_10_30_35 GipsskiveväggsystemPrimär

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Specifikationsdata - Gipsskiveväggsystem

Systemprestanda

Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

42 Rw (dB).

Fire resistance to BS EN 1364-1 and classification to BS EN 13501-2

EI 120.

Duty rating to BS 5234-2

Severe duty (SD).

Maximum height - cold state

3800 mm.

Thickness

102 mm.

Klassificeringsdata

System manufacturer

Protektor Group UK Ltd.

Framing

Protektor ECO or MAXI TEC 50 mm C Stud; Protektor ‘ECO’ 52 mm Deep ‘U’ Channel; Protektor ‘ECO’ 52 mm U Track.

Vägledning för specifikationsalternativ:

Studs:

  • Protektor ECO or MAXI TEC 50 mm C Stud at 300 mm, 400 mm or 600 mm centres depending on heights.

Head detail:

  • Protektor ‘ECO’ 52 mm Deep ‘U’ Channel x 0.5 mm.

Base detail:

  • Protektor ‘ECO’ 52 mm U Track x 0.5 mm.

Track fixing:

  • Protektor ‘U’ Channels fixed at 400 mm centres into a suitable soffit unless stated otherwise.

Insulation

None.

Fire separation

-

Fire-stopping

-

Tillverkarens vägledning

As required for penetrations and for base, head and any abutments to masonry, concrete or steelwork.

Insert requirements.

Linings

Two layers 12.5 mm fire board.

Fasteners

Protektor Drywall Screw’s at 300 mm centres (reduced to 200 mm at external edges).

Joint treatment

-

Tillverkarens vägledning

All boards to be butt-jointed and either paper-taped or taped and jointed, or scrim taped and skimmed.

Insert requirements.

Finish

-

Tillverkarens vägledning

Consult manufacturer and insert requirements.

Seamless finishes: using board manufactures finishing products as per their recommendations and Protektor UK products as clause 471 Protektor paper and corner tape or 680 Seamless finishings using Protektor corner, angle and stop bead.

System accessories

Not required.
Protektor ‘ECO’ 70 mm Bracing Strip x 0.6 mm.

Vägledning för specifikationsalternativ:

  • Fixing type: Protektor 13 mm Wafer Head Screws.
  • Protektor Flat plate to be installed at all horizontal board joints for fire rated partitions and below deflection heads.

Pattress.

Vägledning för specifikationsalternativ:

For plywood installation, Protektor service support plates can be used. These are suitable for either 12 mm, 15 mm or 18 mm.

Höjd

-

Tillverkarens vägledning

Build heights.

Consult manufacturer and insert requirements.

  • 600 mm centres: 3400 mm.
  • 400 mm centres: 3600 mm.
  • 300 mm centres: 3800 mm.

Sealing (joints and penetrations)

Intumescent acoustic sealant.

Vägledning för specifikationsalternativ:

Twin beads of sealant 6 mm to 8 mm in diameter to base and head track to perimeter junctions with walls, floors, and ceilings and around openings. Use expanding intumescent mastic for all fire rated partitions to head and floor channels below head track and board fillets as required.

Deflection

-

Tillverkarens vägledning

For up to 25 mm deflection, use board fillets to allow for a 5–10 mm overlap of vertical boarding against board fillets. Boards fillets should have 2 x 6 mm beads of mastic to the substrate, and 2 x beads of mastic to the head track. Please refer to manufacturer for anything above 25 mm.

Insert requirements or omit.

Standards

To BS EN 1264-1, BS 476, BS 5234-2, BS EN ISO 140-3, BS EN 1364 and BS 7634.

Vägledning för specifikationsalternativ:

  • BS EN 1264-1 / BS476, Fire resistance tests for non-loadbearing elements - Walls.
  • BS 5234-2, Specification for performance requirements for strength and robustness including methods of test.
  • BS EN ISO 140-3, Acoustics - Measurement of sound insulation in buildings and of building elements. Laboratory measurement of airborne sound insulation of building elements.
  • BS EN 1364, Fire resistance tests for non-loadbearing elements.
  • BS 7634, Galvanised Steel Studs and Channels for Stud and Sheet Partitions.

Hållbarhetsdata

Material

Plasterboard
Metal

Liknande produkter från Protektor Group UK

Protektor 126 ‘C’ Stud Partition(s) – 50 mm Stud

Protektor 126 ‘C’ Stud Partition(s) – 50 mm Stud