Mechanically fixed brick cladding system.

Hoppa till:
BOS
+44 (0)121 525 1444 Webbplats

Applikation

For external walls of domestic and non-domestic buildings, above the damp-proof course level in areas with non-severe exposure to chemicals. Suitable for both new build and refurbishment projects. Suitable building substrates include:

  • Steel frame.
  • Concrete frame.
  • Brickwork.
  • Dense concrete blockwork (minimum 1450 kg/m³).
  • Lightweight steel framing.
  • Existing masonry.
  • Timber frame.

Beskrivning

Mechanically fixed, real brick facade system comprising 28mm thick brick slips and aluminium support rails. Available in an extensive range of colours, textures and brick sizes.

Features and benefits:

  • Lightweight - over 50% lighter than traditional masonry, reducing the structural load.
  • Fully mechanically secured brick slips.
  • Non-combustible system components.
  • Versatile brick finishes and detailing options.
  • Metric, linear and imperial brick sizes.
  • Pre-spaced mortar joints.
  • Cost effective for projects where traditional methods of construction are difficult to facilitate.
  • Simple installation using aerial work platforms, reducing the need for scaffolding.
  • Non-weather dependent installation.
  • Can be fitted seamlessly to Ash & Lacy's AxiAL or AxiAL+ rainscreen support systems.
  • Tested to the Centre for Window and Cladding Technology (CWCT) standards.
  • Fire tested to EN13501-1 - A1.
  • BS8414 test data available.
  • BBA Certified

Components:

- Mechanical system components:

  • Starter rail – 23.5 x 18.5 mm (h x w). Available in 3000mm lengths.
  • Intermediate rail – 23 x 11.1 mm (h x w). Available in 3000mm lengths.
  • Top rail – 31 x 18.5 mm (h x w). Available in 3000mm lengths.

- Brick system components:

  • Stretcher and header bricks.
  • Soldier bricks.
  • Corner bricks.
  • Solid aluminium 'brick slip' for fixing external loads.
  • Perforated aluminium 'brick slip' for ventilation.

Allmän information

Färg

Beige

Black

Brown

Cream

Grey

Ivory

White

Other

Red

Visa mer

ytbehandling

Other

Material

Clay

Aluminium

Stainless steel

Form

Other

Rectangle

Längd

215 mm

Bredd

28 mm

Höjd

65 mm

Garanti­beskrivning

25 year

Uniclass

Ss_25_20_70_25 Dränerade och bakventilerade fasadbeklädnadssystemPrimär

CAWS

H92/120 Rainscreen cladding

SKU Code

unknown

Specifikationsdata - Dränerade och bakventilerade fasadbeklädnadssystem

Klassificeringsdata

System performance

Fire performace: Reaction to fire to EN 13501-1:2018, Class A1.

Thermal insulation

-

Tillverkarens vägledning

The use of Rockwool insulation is recommended by the manufacturer in association with MechSlip. Insert requirements.

Secondary support structure

Horizontal application - AxiAL AX1 Support System, anodized aluminium brick slip support rails fixed to vertical support mullions on wall brackets.

Vägledning för specifikationsalternativ:

For fixing to a masonry substrate.

Vertical application - AxiAL AX2 Support System, anodized aluminium brick slip support rails fixed to horizontal support mullions on wall brackets.

Vägledning för specifikationsalternativ:

For fixing to a masonry substrate.

Tillverkarens vägledning

For steel frames, dependent on SFS stud centres, additional ‘top hat’ rails are available if required to fix support rails back to the substrate. Consult manufacturer.

Cavity fire barriers

-

Horizontal

-

Tillverkarens vägledning

Fire cavity barriers are not included within the MechSlip system and should be specified and designed by a

qualified engineer.

Vertical

-

Tillverkarens vägledning

Fire cavity barriers are not included within the MechSlip system and should be specified and designed by a

qualified engineer.

Cladding panels

-

Material

Fired clay brick slips.

Panel joints

Brick spacers and Parex Easipoint Historic pointing mortar.

Vägledning för specifikationsalternativ:

A bucket handle joint profile is recommended. Insert mortar colour requirements.

Reveals

Brick slip reveals.
Metal flashing.

System accessories

Metal finishing trims.
Vent brick slips.

Vägledning för specifikationsalternativ:

Vent brick slips must be installed in required areas to accommodate ventilated facade criteria.

Aluminium brick slips.

Vägledning för specifikationsalternativ:

Aluminium extruded brick slips must be installed in areas

where an external load (camera, light, etc.) will be installed on

the facade.

Third-party certification

BBA Agrément Certificate.

Vägledning för specifikationsalternativ:

MechSlip has undergone BBA testing and assessment to produce both an Ash & Lacy branded certificate (20/5787), and an Ibstock Kevington branded certificate (20/5839).

Colour

Vägledning för specifikationsalternativ:

Over 300 colours available. Colour can be matched to client specifications. Consult manufacturer and insert requirements.


Size

215 x 65 mm.
Other.

Vägledning för specifikationsalternativ:

Imperial or linear sizes can be specified (supplied to the published size tolerances for each brick type). Insert requirements.

Vikt

51.5 kg/m² (approximately).

Tillverkarens vägledning

System weight.

Thermal conductivity

0.71 W/m·K (for clay brick slips).

Impact resistance

Class 1 in accordance with CWCT standard test methods.

Vindmotstånd

±2400 Pa serviceability, ±3600 Pa safety in accordance with CWCT standard test methods.

Tillverkarens vägledning

Wind resistance safety.

Watertightness

600 Pa, in accordance with CWCT standard test methods.

Freeze-thaw resistance

To ETAG 017, Pass; To BS EN 771-1, F2.

HygrothermalRating

To ETAG 034, Pass.

Tillverkarens vägledning

Hygrothermal testing.

Fixings

Stainless steel.

Vägledning för specifikationsalternativ:

Rail/mullion fix screws, thermal pad, fixing screws, and bracket/wall fix screws are supplied where necessary.

Fixings, brackets and support rails are supplied by Ash & Lacy. The quantity calculated on an individual project-by-project

basis.

Hållbarhetsdata

Tydlighet för koldioxidsnål design

NBS LCA hjälper byggproffs att mäta miljöpåverkan och identifiera produkter med låga koldioxidutsläpp för mer hållbara projekt.

Utforska NBS LCA
LCA-illustration

Innehåller Red List-material

No

Materialets ursprungsland

United Kingdom

Produktens tillverkningsland

United Kingdom

Material

Clay
Aluminium
Stainless steel

Produktcertifieringar

BIM-objekt

BOS

NBS BIM-objektstandard

Detta BIM-objekt har skapats för att uppfylla kraven i NBS BIM-objektstandarden.

Läs mer om NBS BIM-objektstandarden.

PlattformKompatibelVersion
Revit
-

1

IFC
-

1

Produktcertifieringar

BBA Agrément Certificate

BBA Agrément Certificate

BBA Certificate - Mechslip Brick Cladding

Environmental Product Declaration

Environmental Product Declaration

EPD - Aluminium Support Systems for Rainscreen Cladding

Dokumentation

Mechslip Brick Cladding

Mechslip Brick Cladding

AxiAL+ Technical Brochure

AxiAL+ Technical Brochure

AxiAL Rainscreen Support Systems

AxiAL Rainscreen Support Systems

CPD-material

The Future of Brick Facades

The Future of Brick Facades

Nyheter

10 Brindley Place, Birmingham

10 Brindley Place, Birmingham

340a Clapham Road

340a Clapham Road

Liknande produkter från Ash & Lacy

LineAL-F Aluminium Cladding System

LineAL-F Aluminium Cladding System

NaturAL-X Brick Cladding

NaturAL-X Brick Cladding

VariAL-CF3 Aluminium Cladding System

VariAL-CF3 Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-TF Metal Cladding System

VariAL-TF Metal Cladding System